Type | WT-H 80A | WT-H 150A | WT-H 416A | WT-H 800A | WT-H 80B | WT-H 150B | WT-H 416B | WT-H 800B | WT-H 80C | WT-H 150C | WT-H 416C | WT-H 800C | WT-H 150D | AHL -416D | WT-H 800D | |
Inside Dimension mm | W | 400 | 500 | 700 | 1000 | 400 | 500 | 700 | 1000 | 400 | 500 | 700 | 1000 | 500 | 700 | 1000 |
H | 500 | 600 | 850 | 1000 | 500 | 600 | 850 | 1000 | 500 | 600 | 850 | 1000 | 600 | 850 | 1000 | |
D | 400 | 500 | 700 | 800 | 400 | 500 | 700 | 800 | 400 | 500 | 700 | 800 | 500 | 700 | 800 | |
Outside Dimension mm | W | 930 | 1030 | 1230 | 1530 | 930 | 1030 | 1230 | 1530 | 930 | 1030 | 1230 | 1530 | 1030 | 1230 | 1530 |
H | 1310 | 1410 | 1660 | 1810 | 1310 | 1410 | 1660 | 1810 | 1310 | 1410 | 1660 | 1810 | 1410 | 1660 | 1810 | |
D | 810 | 910 | 1210 | 1310 | 810 | 910 | 1210 | 1310 | 810 | 910 | 1210 | 1310 | 910 | 1210 | 1310 | |
Volume L | 80 | 150 | 416 | 800 | 80 | 150 | 416 | 800 | 80 | 150 | 416 | 800 | 150 | 416 | 800 | |
Temperature range | 0℃~100℃(150℃) | -20℃~100℃(150℃) | -40℃~100℃(150℃) | -70℃~100℃(150℃) | ||||||||||||
The evenness of Humiture distribution | ±0.5℃ ±3%RH | ±1℃ ±5% | ±0.5℃ ±3%RH | ±1℃ ±5% | ±0.5℃ ±3%RH | ±1℃ ±5% | ±0.5℃ ±3%RH | ±1℃ ±5% | ||||||||
Temperature rising speed | 0℃~100℃about20min | -20℃~100℃about35min | -40℃~100℃about40min | -70℃~100℃about60min | ||||||||||||
Temperature falling speed | 20℃~0℃about20min | 20℃~-20℃about45min | 20℃~-40℃about60min | 20℃~-70℃about90min | ||||||||||||
Freezing system | one-dimensional fully sealed air cooling system | two-dimensional fully sealed air cooling system | three-dimensional fully sealed air cooling system | |||||||||||||
Humidity range | 20%~99%RH | humiture stability | ±0.2℃ ±2%RH | |||||||||||||
Humiture adjustment | the modes of balancing temperature and humidity adjustment | outside materials | stainless steel sus # 304 | |||||||||||||
Inside materials | stainless steel sus # 304 | humidifying system | surface evaporation, humidifier with stainless steel heating and equipped with a power off device when humidifier wants water and an over-temperature protection device. | |||||||||||||
Thermal material | heat preserved by rock wool and hardened pu foaming | heating system | heater with stainless steel dissipation | |||||||||||||
Circulatory system | convection by fan forced circulatory system | dehumidifying system | freezing dehumidifying system | |||||||||||||
Water supplying system | The advance water tank, fully automatic water supplying control, device for reuse through recovery and circulatory filtering plus a warning device for insufficient water. | |||||||||||||||
Safety devices | leakage and overload protection device, compressor overload protection device, power off device for over-temperature and over humidity, water insufficient protection device, over-temperature protection device for humidifier and the protection device for limit of temperature. | |||||||||||||||
Standard accessories | Two sets of the adjustable SS plate, the vacuum glass windows, the test hole, a lamp inside the operation room and a movable indicator. | |||||||||||||||
Options | Recorder | Power | AC220V、1PH、50/60HZ |