The maximum operating temperature of cores shall not exceed 70 oC when the cable is used for long period. The temperature of cores shall not exceed 160oC at short circuit for 5 seconds. The ambient temperature should not be below 0 oC during installation. The minimum bending radius shall not be less than 10 times of the cable diameter when laying. The single cable should not be laid in magnetic ducts when it is electrified with alternating current.
Operation characteristic
Type of PVC cable | Type of fire retardant PVC cable | Description | Application |
V(L)V | ZR- V(L)V ZRB- V(L)V ZRA- V(L)V | PVC insulated PVC sheathed power cable | For laying indoors, in tunnels and in ducts, unable to bear external mechanical forces. |
V(L)V22 | ZR-V(L)V22 ZRB-V(L)V22 ZRA- V(L)V22 | PVC insulated PVC sheathed steel tape armoured power cable | For laying indoors, in tunnels and in ducts, able to bear external mechanical forces. |
V(L)V32 | ZR- V(L)V32 ZRB- V(L)V32 ZRA- V(L)V32 | PVC insulated PVC sheathed internal fine steel wire armoured cable | For laying indoors, in shafts and in water, able to bear moderate pulling forces. |
Type, description and application
4 -400
5
VLV32
VLV22
VLV
4 - 400
5
VV VV22 VV32
4 - 400
4
VLV32
VLV22
VLV
4 - 400
4
VV VV22 VV32
4 - 400
3+1
VLV32
VLV22
VLV
4 - 400
3+1
VV VV22 VV32
4 - 400
2.5 - 400
3
VLV32
VLV22
VLV
4 - 400
3
VV VV22 VV32
4 - 400
2.5 - 400
2
VLV32
VLV22
VLV
4 - 400
1.5 - 400
2
VV VV22 VV32
2.5 - 630
1
VLV
1.5 - 630
1
VV
Nominal cross-sectional area(mm2)
No. of cores
Type
Nominal cross-sectional area(mm2)
No. of cores
Type
Specification
Property and Function: It is suitable to be installed in the four wires system with rated voltage of 0.6/1KV(U
PVC Insulated PVC Sheathed Power Cable The cable is manufactured according to GB12706-91or IEC502-1994.
Package: | The supply length of completed cable is 100m or above per reel. |
Minimum Order Quantity: | 1000 Meter |
Payment Terms: | T/T |
Port: | Ningbo |
Jacket: | PVC |
Conductor Material: | Copper |
Type: | Low Voltage |
Insulation Material: | PVC |
Model Number: | V(L)V V(L)V22 V(L)V33 |
Brand Name: | Bate |
Place of Origin: | Zhejiang China (Mainland) |
3 core pvc flexible cable 3 core pvc cable PVC insulated 3 core power cables are normally used in power transmission and distribution systems. The 3 core PVC flexible cables are referred to IEC60502 CU/PVC/PVC 0.6/1KV. The circular conductor is applied for the size below 16㎡ ...
Description of 3Cores+1 Earth Power Cable (PVC Insulated) Rated Temperature: 70℃ Rated Voltage: 600/1000V Reference Standard: GB/T12706, IEC60502 Model: VV Shaped and circular stranded copper conductors Flame retardant insulated with PVC compound PVC bedded Flame retardant ...
PVC insulated 2 cores power cables are normally used in power transmission and distribution system. The 2 core PVC cables are referred to IEC60502 CU/PVC/PVC 0.6/1KV. The circular conductor are applied for the size below 16mm² and the shaped conductor is applied for the size ...
6181Y cable refers to the cables of single core with double insulation. It is widely used in the fixed installation, domestic and industrial lighting With the voltage 300/500v. We supply the 6181y 25mm single core double insulated flexible cable size up to 35mm² by BS6004. For ...
PVC insulated 3 core power cables are normally used in power transmission and distribution systems. The 3 core PVC flexible cable are referred to IEC60502 CU/PVC/PVC 0.6/1KV. The circular conductor is applied for the size below 16㎡ and the shaped conductor is applied for the ...
The structure of 3cores+1earth is designed for application where the earth wires are required according to customer requirements. These cables are often referred 3 cores +1 cables with voltage 0.6/1000v or IEC 60502 3 cores +1 cables. 3 Cores+1 Earth Power Cable (PVC Insulated) ...
PVC insulated 2 cores power cables are normally used in power transmission and distribution system. The 2 core pvc cable are referred to IEC60502 CU/PVC/PVC 0.6/1KV. The circular conductor are applied for the size below 16mm² and the shaped conductor is applied for the size ...
Control cable is applicable to industrial and mining enterprises, energy and transport sector, for ac rated voltage up to 450/750 v control, protecting circuits using PVC insulated, PVC sheathed control ...
Come From Shanghai Hongsheng Wire and Cable Co Ltd
Wire cloth It\'s a wire that transports electricity.It is divided into bare wire, electromagnetic wire and insulated wire.There are no insulation layers, including copper, aluminum flat wire, overhead wires, and various profiles (such as profile, bus, copper, aluminum, etc.).It ...
Come From Shanghai Hongsheng Wire and Cable Co Ltd
For laying buildings,inducts , Metal tunnels,direct in ground and under water nominal cross-sectional areas: 1.5 mm2, 2.5 mm2,4 mm2, 6 mm2, 10 mm2, 16 mm2,25 mm2, 35 mm2, 50 mm2,70 mm2, 95 mm2,120 mm2,150 mm2,185 mm2,240 mm2,300 mm2400 mm2500 mm2630 mm2800 mm2 Specifications ...