Assembly:
1. Conductor copper, round-shaped, area range of 1.0 to 4.0 mm2, according to class 3, area range of 6 to 400 mm2, according to class 2.
2. Isolator its allowed to apply synthetic films around the conductors (under the insulation) of cables
3. Insulation insulating rubber.
4. Twisting Insulated conductors of cables are twisted to form a cable using concentric layers in different directions. It is allowed to twist insulated conductors in concentric layers in one
direction. Insulated conductors of two conductor cables of up to and including 4 mm2 of area can be positioned in parallel. Each layer of cables with conductor areas of up to and including 2.5 mm2
has a count conductor and leader conductor. When cabling insulated conductors it is allowed to use a rubber cord as a filler.
5. Isolator a single synthetic film is applied over the insulation of single conductor cables or an outer layer of insulated conductors of cable.
6. Inner sheath of PVC or rubber as option.
7. Screen is applied over the inner sheath in the form of two layer braiding or serving with 80% density of maximum 0.3 mm diameter copper wires Cable screen can be made with a copper tape not more
than 0.5 mm thick in form of taping with minimum 25% overlapping.
8. Isolator It is allowed to apply a single synthetic film over the wire braiding, serving or copper taping.
Application:
KNREk vessel cables are intended for use in power and lighting networks, control circuits, alarm units and interconnections.They are designed for fixed laying applications indoors and on the open
deck provided that they are protected against solar radiation effects including those of vapors and condensate of oils and fuels, vapors of acids, alkalis, apatite, coal, cement and other dusts,
flour from fish and other fish products in fish processing shop and refrigerator room conditions as well under the effects of radial hydrostatic pressure of up to 1.96 MPa (20 kgs/cm2).
Technical details:
Cables are designed for operation in ambient temperature range of..+45 oC to 40 oC
Cables shall be laid and installed without preheating at temperatures not lower than-15 oC
Cables are resistant to the effects of 100 % relative humidity of the air at.. +35 oC
Cables are resistant to vibration and single impact loads
Cables are resistant to sea water
Cables are flameretardant if laid singly
Bending radius during the installation of cables in places where the access is impeded shall account for at least3 outer diameters of cable when the number of bending at one place is not more than
two
Bending radius during the installation of fixed cables shall account for at least. 5 outer diameters of cable
Cables shall withstand alternate current voltage test of..2500 V
Electric resistance of insulation at +20 oC at least.120 MOm/km
Continuously permissible temperature of conductor at least+75 oC
Cable construction length at least125 m
Guarantee service life5 years from the day of putting a cable into operation
Minimum service life .25 years
Tabulated data
OKP codes:
35 8643 01 KNRk cables
KNREk vessel cables are intended for use in power and lighting networks, control circuits, alarm units and interconnections.They
Package: | on wooden drums in 20/40' containers |
Minimum Order Quantity: | 2000 Meter |
Payment Terms: | T/T |
Brand Name: | Electrocable works |
Place of Origin: | Russian Federation |
Jacket:Rubber Conductor Material:Copper Application:Mining Type:High Voltage Insulation Material:PVC Model Number:vv32 Brand Name:goodmark Place of Origin:China (Mainland) Copper conductor,PVC insulated,steel wire armoured,PVC sheathed power cable ,. ...
Brand Name:Electrocable works Place of Origin:Russian Federation KNRk vessel cables are intended for use in power and lighting networks, control circuits, alarm units and interconnections.They ...
Come From Seafartrans Co Ltd
Number of Cores and Nominal Area of Conductor Thickness of insulation (Nominal) Thickness of inner sheath (Minimum ) Armour wire diameter or steel strips (Dimensions) Thickness of outer sheath (minimum) Approx. Overall (diameter) Total weight approx. Maximum DC resistance of ...
Come From Orient Cables India Pvt. Ltd.
Jacket:PVC Conductor Material:Aluminum Application:Where Poser Cable is required Type:Low Voltage Insulation Material:PVC Brand Name:OrientCab, Ori-net Place of Origin:Delhi India We make 1.1 KV LT PVC/XLPE Insulated,PVC Sheathed,Armoured/Unarmoured Power Cable in ...