st.
4.06
200
10.47
1000
2.78
100
9.82
900
1.91
50
8.47
700
0.86
10
6.01
400
0.30
1
Max. (dB/100 ft.)
Frequency (MHz)
Max. (dB/100 ft.)
Frequency (MHz)
[@68o F. (20o C.)]
Attenuation
3) Attenuation
20dB (10-350MHz) 100% Swept Tested
SRL:
15dB min(860-2500Mhz)
20dB min (5-860MHz)
Return Loss:
6.6 Ohms/1000Ft(Nom.) 18 AWG
10.5 Ohms/1000Ft.(Nom.) Coax
DCR: Conductor:
84%
Velocity of Propagation:
16.0pF./Ft. Nom.
Capacitance:
75+3 Ohm
Impedance: |
||||||||
Dielectric Strength: Conductor to Shield: 2000VDC |
||||||||
Spark Test: 2000 VAC 2) Characteristics |
Jacket: (2-18): 3.81mm
Dielectric: Solid PE 1.85mm
2-18 AWG Stranded Copper (7X0.38mm)
|
|||||||
|
Delivery Time: | within two weeks |
Package: | Packing:1) Packing Lengths: 100m/roll, 200m/roll, 305m/roll, 500m,100yard/roll, 200yard/roll, 300yard/roll Other lengths available according to client's request; 2) Inner packing: Wooden reel, plastic reel, and paper reel available. 3) Outer packing: Carton box, pull out box, pallet available. 4) Other packing terms available according to client's requests. |
Supply Ability: | 5000 Kilometer per Week |
Minimum Order Quantity: | 50 Kilometer |
Payment Terms: | L/C,T/T |
XLPE power cables are normally used in power transmission and distribution systems. The xlpe 2cores flat cable is referred to as IEC60502 CU/XLPE/PVC 0.6/1KV. The circular conductor is applied for the size below 16mm² and the shaped conductor is applied for the size above and ...
PVC insulated 2 cores power cables are normally used in power transmission and distribution system. The 2 core PVC cables are referred to IEC60502 CU/PVC/PVC 0.6/1KV. The circular conductor are applied for the size below 16mm² and the shaped conductor is applied for the size ...
XLPE insulated 2 core power cable are normally used in power transmission and distribution systems. The 2 core XLPE cable is referred to as IEC60502 CU/XLPE/PVC 0.6/1KV. The circular conductor is applied for the size below 16mm² and the shaped conductor is applied for the size ...
PVC insulated 2 cores power cables are normally used in power transmission and distribution system. The 2 core pvc cable are referred to IEC60502 CU/PVC/PVC 0.6/1KV. The circular conductor are applied for the size below 16mm² and the shaped conductor is applied for the size ...
USES special compression technology and annealing treatment advanced technology invention of new materials such as power cables, aluminum alloy power cable has good mechanical properties and electric properties, it can be widely used to national economy each domain. Performance: ...
Come From Shanghai Hongsheng Wire and Cable Co Ltd
Construction Material Nominal Size Inner Conductor BC/CCS Φ0.81mm Insulation FPE Φ3.66mm 1stShield(Tape) Bonded AL FOIL 2nd Shield(Braid) AL/ BC 60% Coverage 3rd Shield(Tape) AL FOIL Outer Sheath PVC/PE Φ6.20mm ...
Come From Superlink Cable Co.
Construction Material Nominal Size Inner Conductor BC/CCS Φ0.81mm Insulation FPE Φ3.66mm 1stAl Foil Bonded AL FOIL 2ndBraiding AL/ BC 60% Coverage Outer Sheath PVC/PE Φ6.10mm ...
Come From Superlink Cable Co.
Construction Material Nominal Size Inner Conductor BC/CCS Φ0.81mm Insulation FPE Φ3.66mm 1stAl Foil Bonded AL FOIL 2nd Braiding AL/ BC 60% Coverage Anticorrosive Adhesive Jelly Outer Sheath PVC/PE Φ6.10mm ...
Come From Superlink Cable Co.
Construction Material Nominal Size Inner Conductor BC/CCS Φ0.81mm Insulation FPE Φ3.66mm 1stAl Foil Bonded AL FOIL 2nd Braiding AL/ BC 60% Coverage Outer Sheath PVC/PE Φ6.10mm Power cable Material Nominal Size Inner Conductor BC/CCS 7*Φ0.38mm Insulation PVC Black,Red ...
Come From Superlink Cable Co.
Construction Material Nominal Size Inner Conductor BC/CCS Φ0.81mm Insulation FPE Φ3.66mm 1stAl Foil Bonded AL FOIL 2nd Braiding AL/ BC 60% Coverage 3rdAl Foil AL FOIL 4thBraiding AL/BC 40% Coverage Outer Sheath PVC/PE Φ6.73mm ...
Come From Superlink Cable Co.