Product name: CT PT Analyzer

Product model: GDVA-405

Tests for Current Transformer:

1 Excitation curve and parameters test
2 Turns ratio test
3 Ratio and phase error test
4 Polarity mark check
5 Winding resistance measurement
6 Secondary loop burden measurement
7 Error line curve test for protection CT
8 Transient CT parameters test
9 CT nameplate guess
10 Saturation hysteresis loop curve measurement

Tests for Voltage Transformer:

1 Turns ratio test
2 Ratio error and phase angle error test
3 Polarity test
4 Secondary burden test
5 Winding resistance test

Applications of CT/PT Analyzer:

1 CT nameplate check
2 CT parameters check in work burden
3 CT transient parameters analysis
4 CT ratio and phase error calibration
5 PT routine test

CT PT Analyzer Function and Technical Index:

1 Test standards: IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
2 Power supply: AC220V±10%, 50/60Hz±10%
3 Voltage output: 0.1~180V (AC)
4 Current output: 0.001~5A(RMS)
5 Power output: 500VA
6 Maximum knee voltage measurement: 45KV
7 Current measurement:
Range: 0~10A (automatically change range in 0.1/0.4/2/10A)
Error: <±0.1%+0.01%FS
8 Voltage measurement:
Range: 0~200V (automatically change range in 1V/10V/70V/200V)
Error: < ±0.1%+0.01%FS
9 Turns ratio measurement:
Range:1~35000
1~2000 error<0.05%
2000~5000 error<0.1%
5000~35000 error<0.2%
10 Phase measurement: error: ±2min; resolution: 0.01min
11 Winding resistance measurement:
Range: 0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)
Error: < 0.2%RDG+0.02%FS
Maximum resolution: 0.1mΩ
12 Temperature measurement:-50~100 Celsius degree; error<3 Celsius degree
13 CT Secondary burden:
Range: 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
Error: <0.2%RDG+0.02%FS
Maximum resolution: 0.001ohm
14 PT Secondary burden:
Range: 0~80kohm (automatically change range in 800ohm/8kohm/80kohm)
Error :<0.2%RDG+0.02%FS
Maximum resolution: 0.1ohm
15 PT ratio measurement:
Range: 1~35000
1~10000 error<0.1%
10000~35000 error<0.2%
16 PT ratio error measurement: Typical error <0.05%, Maximum Error<0.1%
17 PT phase angle measurement: maximum error < 3min
18 Make evaluation for test results according to selected standards
19 Make word report for test result
20 Make word reports one time for multi-group test records on the PC
21 Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test
22 Compare excitation curves with saved excitation curves in the same window
23 Memory capacity: >1000 groups test results
24 Working condition: temperature: -10℃~50℃; moist: ≤90%

  • Country: China (Mainland)
  • Business Type:
  • Market:
  • Founded Year:2009
  • Address:重庆市南岸区南坪金台大厦9-10
  • Contact:Daisy Tao
more images of Multi-function Voltage Transformer Testing Set
*Your name:
*Your Email:
*To:重庆格纳迪机电设备有限公司
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters : 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

submiting now We do inquire for you , please wait ...

High Voltage Electrical Transformer Testing Oil type hipot test equipment
High Voltage Electrical Transformer Testing Oil type hipot test equipment

High Voltage Electrical Transformer Testing Oil type hipot test equipment Introduction: GDJ Series Oil Immersed Test Transformer AC DC Hipot Tester for Cable Withstand Voltage Testing is applied in power system for insulation test of high voltage equipment. The typical ...

GOLD

Low voltage low frequency current transformer/ electric transformer/small transformer for TV set
Low voltage low frequency current transformer/ electric transformer/small transformer for TV set

TaizhouBairui Electronic Technology was founded in 2006, is located in the flood plain tea Island industrial area generation. 9 years, committed to the development, production, sales of all kinds of high, medium and low frequency electronic transformers, inductors, reactance, ...

TAIZHOU BAIRUI ELECTRONIC TECHNOLOGY CO.LTD

GDBC-901 Transformer Voltage Ratio Test Kit
GDBC-901 Transformer Voltage Ratio Test Kit

GDBC-901 Transformer Voltage Ratio Test Kit 1. Product introduction GDBC-901 Transformer Voltage Ratio Test Kit is designed according IEC76-1 and IEC60044. GDBC-901 Transformer Voltage Ratio Test Kit can be applied to test the ratio of single or three phase transformer. Also ...

重庆格纳迪设备有限公司

GDBC-901 Voltage and Turn Ratio Test of Transformer
GDBC-901 Voltage and Turn Ratio Test of Transformer

GDBC-901 Voltage and Turn Ratio Test of Transformer 1. Product introduction GDBC-901 Voltage and Turn Ratio Test of Transformer is applied to measure the voltage ratio of three or single phase transformer. All the data and test results are shown on a 320*240 LCD screen. All the ...

重庆格纳迪设备有限公司

GDJJ-II Insulating Oil Breakdown Voltage Test Set
GDJJ-II Insulating Oil Breakdown Voltage Test Set

GDJJ-II Insulating Oil Breakdown Voltage Test Set Brief Introduction GDJJ-II Insulating Oil Breakdown Voltage Test Set is produced according to the National Standard GB-86 Determination Method for Dielectric Strength of Transformer Oil. The parameters are set in advance with ...

重庆格纳迪设备有限公司

GDYJ-502 Transformer Oil Breakdown Voltage (BDV) tester, Oil dielectric test set
GDYJ-502 Transformer Oil Breakdown Voltage (BDV) tester, Oil dielectric test set

I.Functions: 1 Breakdown test of user-defined 2 Proof test 3 IEC60156/IS6792/BS5874 test 4 ASTM D1816 standard test 5 ASTM D877 standard test 6 5 minutes standard test 7 Manual test 8 Calibration interface for customers 9 Uploading data to PC and making word report ...

ChongQing Gold Machine& Electric Equipment Co., Ltd.

DC HIGH VOLTAGE TEST SET

Phase:Other Usage:Instrument Place of Origin:India DC HIGH VOLTAGE TEST SET ...

R.R.ENTERPRISES

High Voltage Test Transformer

Rex Instruments is Well known for its high quality Cable Testing Instrument, Transformers, current Transformer, Stabilizers, Scientific Testing Instruments ...

Rex Instruments