CT PT Tester Current Transformer Tester Potential Transformer Tester

Place Of Origin
Chongqing of China
Packaging
Wooden Case
Delivery
10 Days

Product name: CT PT Analyzer

Product model: GDVA-405

Tests for Current Transformer:

1 Excitation curve and parameters test
2 Turns ratio test
3 Ratio and phase error test
4 Polarity mark check
5 Winding resistance measurement
6 Secondary loop burden measurement
7 Error line curve test for protection CT
8 Transient CT parameters test
9 CT nameplate guess
10 Saturation hysteresis loop curve measurement

Tests for Voltage Transformer:

1 Turns ratio test
2 Ratio error and phase angle error test
3 Polarity test
4 Secondary burden test
5 Winding resistance test

Applications of CT/PT Analyzer:

1 CT nameplate check
2 CT parameters check in work burden
3 CT transient parameters analysis
4 CT ratio and phase error calibration
5 PT routine test

CT PT Analyzer Function and Technical Index:

1 Test standards: IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
2 Power supply: AC220V±10%, 50/60Hz±10%
3 Voltage output: 0.1~180V (AC)
4 Current output: 0.001~5A(RMS)
5 Power output: 500VA
6 Maximum knee voltage measurement: 45KV
7 Current measurement:
Range: 0~10A (automatically change range in 0.1/0.4/2/10A)
Error: <±0.1%+0.01%FS
8 Voltage measurement:
Range: 0~200V (automatically change range in 1V/10V/70V/200V)
Error: < ±0.1%+0.01%FS
9 Turns ratio measurement:
Range:1~35000
1~2000 error<0.05%
2000~5000 error<0.1%
5000~35000 error<0.2%
10 Phase measurement: error: ±2min; resolution: 0.01min
11 Winding resistance measurement:
Range: 0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)
Error: < 0.2%RDG+0.02%FS
Maximum resolution: 0.1mΩ
12 Temperature measurement:-50~100 Celsius degree; error<3 Celsius degree
13 CT Secondary burden:
Range: 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
Error: <0.2%RDG+0.02%FS
Maximum resolution: 0.001ohm
14 PT Secondary burden:
Range: 0~80kohm (automatically change range in 800ohm/8kohm/80kohm)
Error :<0.2%RDG+0.02%FS
Maximum resolution: 0.1ohm
15 PT ratio measurement:
Range: 1~35000
1~10000 error<0.1%
10000~35000 error<0.2%
16 PT ratio error measurement: Typical error <0.05%, Maximum Error<0.1%
17 PT phase angle measurement: maximum error < 3min
18 Make evaluation for test results according to selected standards
19 Make word report for test result
20 Make word reports one time for multi-group test records on the PC
21 Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test
22 Compare excitation curves with saved excitation curves in the same window
23 Memory capacity: >1000 groups test results
24 Working condition: temperature: -10℃~50℃; moist: ≤90%

  • Country: China (Mainland)
  • Business Type:
  • Market:
  • Founded Year:2009
  • Address:重庆市南岸区南坪金台大厦9-10
  • Contact:Daisy Tao
more images of CT PT Tester Current Transformer Tester Potential Transformer Tester
*Your name:
*Your Email:
*To:重庆格纳迪机电设备有限公司
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters : 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

submiting now We do inquire for you , please wait ...

GDVA-405 Transformer Polarity CT PT Tester /CT PT Tester For Transformer
GDVA-405 Transformer Polarity CT PT Tester /CT PT Tester For Transformer

GDVA-405 Transformer Polarity CT PT Tester /CT PT Tester For Transformer Application ...

重庆格纳迪设备有限公司

GDBC-901 Current Transformer Transformation Ration Tester
GDBC-901 Current Transformer Transformation Ration Tester

GDBC-901 Current Transformer Transformation Ratio Tester 1. Product introduction Current Transformer Transformation Ratio Tester is applied to measure the voltage ratio of three or single phase transformer. All the data and test results are shown on a 320*240 LCD screen. All ...

重庆格纳迪设备有限公司

GDVA-402 CT PT Transformer Tester Set
GDVA-402 CT PT Transformer Tester Set

I Brief Introduction This CT PT transformer tester set is a special equipment for testing characteristic of CT and PT .The tester can finish CT/PTtransformation ratio test, CT/PT polarity test, volt-ampere feature curve drawing and CT error drawing. It has large output, high ...

重庆格纳迪设备有限公司

GDVA-404 CT PT Tester/ Current and Potential Transformer Tester
GDVA-404 CT PT Tester/ Current and Potential Transformer Tester

I Introduction This CT PT tester/ current and potential transformer tester is performing excitation, ratio and phase error, polarity, secondary loop burden and coil resistance on current and voltage transformer. The instrument provides fully automatic testing and calibration ...

重庆格纳迪设备有限公司

DGVA-404 Current Transformer Tester,Potential Transformer Tester
DGVA-404 Current Transformer Tester,Potential Transformer Tester

Application Tests for current transformer: 1)Excitation curve and parameters test 2)Turns ratio test 3)Ratio and phase error test 4)Polarity mark check 5)Coil resistance measurement 6)Secondary loop burden measurement 7)Error line curve test for protection CT 8)Transient CT ...

ChongQing Gold Mechanical & Electrical Equipment Co., Ltd.

' METER \TESTER / Current Transformer / SFT Current Transformers / Transformer '

Coil Number:Autotransformer Coil Structure:Other Phase:Single Usage:Current Model Number:SFT Current Transformers Brand Name:Good Place of Origin:Zhejiang China (Mainland) Rated frequency: 50/60Hz Rated voltage:0.72V ...

Yueqing Good Electric Co., Ltd.

' METER \TESTER / Current Transformer / DX Current Transformers DSM/DS / Transformer '

Coil Number:Autotransformer Coil Structure:Other Phase:Single Usage:Current Model Number:DX Current Transformers DSM/DS Brand Name:Good Place of Origin:Zhejiang China (Mainland) Rated frequency: 50/60Hz Rated voltage:660V ...

Yueqing Good Electric Co., Ltd.