When our slurry pump has abnormal noise or friction, or we have dismantled the pump and replaced the impeller during maintenance, or the disc does not move when the hand pump is operated, then we need to pay attention to whether there is a problem with the impeller clearance. . So how to adjust the impeller clearance? ShijiazhuangPansto Pump Industry has published a detailed tutorial, hoping to help friends in need.

as the picture shows:

1. You need to stop the pump first, and then loosen the four bolts that compress the bearing assembly.

2. There is an adjusting bolt under the bearing assembly. Turn the nut on the adjusting bolt to move the bearing assembly forward, and at the same time turn the shaft by hand in the direction of pump rotation until the impeller rubs against the front sheath.

3. In the same way, move the bearing assembly backward to make the impeller contact the rear sheath.

4. Steps 2 and 3 are to measure the contact distance of the bearing assembly moving forward and backward. Take half of this distance as the correct gap between the impeller and the front and rear sheaths.

5. Then use the adjusting bolt to adjust the position of the bearing assembly to ensure the correct gap value between the impeller and the front and rear sheaths.

6. Finally tighten the four bolts that hold down the bearing assembly.

The above are the specific steps for adjusting the impeller clearance. If there is anything you still don’t understand, please feel free to call ShijiazhuangPansto Pump Industry to provide you with professional technical consultation and selection quotations.

Email: laurashi@panstopump.com, Whatsapp: +86-15732149758

  • Country:
  • Business Type:
  • Market:
  • Founded Year:
  • Address:
  • Contact:Laura Shi
*Your name:
*Your Email:
*To:Pansto Pump Co., Ltd
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters : 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

submiting now We do inquire for you , please wait ...

How to adjust the impeller clearance of ZJ slurry pump
How to adjust the impeller clearance of ZJ slurry pump

There is a correct gap value between the impeller and the rear guard plate of the slurry pump. We have previously introduced the method of adjusting the impeller clearance of the AH slurry pump. Today we will introduce how to adjust the impeller clearance of ZJ slurry pump. ...

Pansto Pump Co., Ltd

How to adjust impeller clearance for AH type slurry
How to adjust impeller clearance for AH type slurry

The impeller clearance of the AH type slurry pump is adjusted when it leaves the factory. Therefore, there is generally no need to adjust the impeller clearance when the new machine arrives at the site. So when does it need to be adjusted? Shijiazhuang slurry pump manufacturer ...

Pansto Pump Co., Ltd