G506 Mask Automatic Filter Performance Tester

Place Of Origin
china
Minimum Order
1
Packaging
Packed by solid wooden case;
Delivery
15 Days
The latest G506 mask automatic filter performance tester uses the most advanced technology and design concepts, to meet a variety of test standards and the latest National standard GB / T 32610.Only relatively little operation is required tocomplete all the function and operation. Hardware performance of G506 mask automatic filter performance tester is stable and excellent in repeatability. Software design meet with people's thinking mode, the interface is user-friendly, and the functional and parameter settings are very reasonable. It is convenient to userforacademic research and product development.

Application:
G506 Mask Automatic Filter Performance Tester is used for
testingprofessional filter material and filtration efficiencyof a wide range of air filters including HEPA and ULPA filter, respirator, filter cartridge and protective clothing test. It also can use salt or oil mist to test filter media. Rapid acquisition of filter media performance evaluation parameters, and accurate evaluation of filter material quality, performance, life and so on. It is convenientto userforacademic research and product developmentof new filter materials, product quality control, material performance verification.

Standards
EN 143 Protection device, particle filter requirement, test, mark
EN 149 Respiratory protection device, microparticle filter with half mask required test mark
NIOSH 42 CFR Part 84 Respiratory protection device
GB/T 2626 Self - priming filter type particulate respirator of Respiratory protective equipment
GB/T 32610 Technical specification for daily protective masks
Structure principle
G506 mask automatic filter performance tester, composed of the following key components;
1. Salt oil mist aerosol generator;
2. Heater and mixer;
3. Aerosol charge neutralizer;
4. Particle counter or laser scatter photometer;
5. Sample holding device;
6. Pressure drop measuring device;
7. Temperature, humidity, atmospheric pressure sensor;
8. Filtration systems, vacuum pumps, and discharge systems

Test principle
Clean compressed air will carry pre-prepared solution such as NaCl solution or DEHS / PAO from the aerosol generator. After a classifier , unwanted large particles are collected into the collection bottle, wanted aerosol particles are sprayed from the aerosol generator nozzle into the test system.
Before the aerosol reaches the test media, it emitted by the aerosol generator requires two procedures; 1. The aerosol salt particles are produced by mixing with the heated gas (for salt mist).2. To neutralize the aerosol is by electrostatic neutralizer, which is used to reduce the effect of particle loss and static electricity on the test results.
After two procedures above, aerosol with a certain flow rate to reach the test filter surface, and start the test program. For the filter efficiency test, the test time is very short, only need a few seconds to complete a filter test. Experiments for loading experiments are relatively long.
The mass concentration or mass concentration of aerosol upstream and downstream of the filter media was measured by particle counter or laser scattering photometer, and the filtration efficiency was calculated. The pressure drop across the filter was monitored by differential pressure sensor
Main monitoring quantity
Aerosol electrostatic neutralization effect monitoring;
Downstream aerosol concentration monitoring;
The flow of the test;
Pressure drop on both sides of the filter;
Filter resistance;
Upstream aerosol concentration monitoring
Temperature, humidity, atmospheric pressure
Aerosol generation gas supply pressure;
Filtration efficiency / transmittance;

Technical Parameters
Items Parameters
Type of aerosol Emery 3004,DOP,DEHS, Paraffin NaCl
Average mass diameter 0.33um 0.26um
Average number of diameters 0.20um 0.07um
Geometric deviation <1.6 <1.83
Aerosol concentration 50-200mg/m3 15-20mg/m370L/min
Aerosol monitoring Laser scatter photometer or particle counter
Monitoring range 1.0ug/m3-200mg/m3
Flow monitoring Vane flowmeter with pressure sensor
Monitoring range 15-100L/min
Monitoring accuracy 2% of full scale
Pressure monitoring electronic pressure sensor / differential pressure sensor
Monitoring range 0-15cm H2O
Monitoring accuracy 2% of full scale
Filtration efficiency measurement
The flow of through filter material 15-100L/min
Measurement accuracy Penetration rate 0.001%; filtration efficiency of up to 99.999%;
Automation and electrical control and data acquisition Microprocessors
Output LED display;RS-232 communication interface
Operational requirements
Power supply 100-120VAC 60Hz 5A or 230-240VAC 50Hz 2.5A
Compressed air requirements 80 psig 7scfm (550kpa, 198std L/min)
Aerosol vents requirements 7scfm (198std L/min)
Environmental requirements 10-50 degrees, no condensation, no wet environment Size 80 * 100 * 150cm
Weight 100kg
The noise level Less than 75dB
  • Country:
  • Business Type:
  • Market:
  • Founded Year:
  • Address:
  • Contact:QIAN qian
more images of G506  Mask Automatic Filter Performance Tester
  • wangmigel_manager20@MY,2020-05-13 15:12:38
    Greetings Sirs and Madams,

    Hope I find you in good health?

    My name is Wang Miguel I am the Proprietor of MULTI SERVICE LLC, is a Retail and Trading company located in .....

    Hope your company can receive order now?

    Kindly Provide me with your website link/catalog via WhatsApp ........... as we are working from home so we can choose precisely the needed products required by our client. Await your message on our email contact address below ( Wangmigel_manager20@hotmail.com)

    Regards,
    Wang Miguel
*Your name:
*Your Email:
*To:Qinsun Instruments (Shanghai) Co., Ltd.
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters : 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

submiting now We do inquire for you , please wait ...

Automated Mask Filter Tester G506
Automated Mask Filter Tester G506

Product Profile Thefiltration efficiency test equipment The device consists of NaCL cargo oil generator, air flow meter, humidifier, sealed box and corresponding pipeline. Air source system Exhaust air volume: 10 ± 100L / M Solid aerosol particle size: 0.075 ± 0.02um ...

Qinsun Instruments (Shanghai) Co., Ltd.

EN 143 Mask Automatic Filtering Performance Tester - Qinsun
EN 143 Mask Automatic Filtering Performance Tester - Qinsun

Product Introduction Medical surgicalmask particle filtration efficiency tester Technical StandardGB2626-2006----Respiratory protective equipment--Non-powered air-purifying particle respirator GB/T 32610-2016---Technical specification of daily protective mask ...

Qinsun Instruments (Shanghai) Co., Ltd.

Melt-blown fabric and mask automatic filter performance tester
Melt-blown fabric and mask automatic filter performance tester

Melt-blown fabric and mask automatic filter performance tester uses the most advanced technology and design concepts, to meet a variety of test standards and the latest National standard GB / T 32610.Only relatively little operation is required to complete all the function and ...

stgoup

EN 143 Mask Automatic Filtering Performance Tester
EN 143 Mask Automatic Filtering Performance Tester

mask automatic filter performance tester uses the most advanced technology and design concepts, to meet a variety of test standards and the latest National standard GB / T 32610.Only relatively little operation is required to complete all the function and operation. Hardware ...

Qinsun Instruments (Shanghai) Co., Ltd.

China Automated Filter Tester 8130A  Mask filter performance tester
China Automated Filter Tester 8130A Mask filter performance tester

     Mask filter performance tester utilizes advanced technology and microprocessor for controlling.  The tester is designed with a good user interface and setting mode, which can simplify the training and operation. The test results directly display, easy and quickly.   ...

Qinsun Instruments (Shanghai) Co., Ltd.

Mask automatic filtering efficiency tester
Mask automatic filtering efficiency tester

Test Standards EN 143 Protection device, particle filter requirement, test, mark EN 149 Respiratory protection device, microparticle filter with half mask required test mark NIOSH 42 CFR Part 84 Respiratory protection device GB/T 2626 Self - priming filter type particulate ...

Qinsun Instruments (Shanghai) Co., Ltd.