| IGBT-500V300A | ||||||||||
| Model: | IGBT- | 500 | V | 300 | A | Battery Testing System | Material Code: | CE-7001 | - | 500V300A |
| Description | Product Specification | |||||||||
| AC Input | AC 380V±10% 50Hz | |||||||||
| Single-phase Power | 50 | KW | ||||||||
| Single-phase Current | 253 | A | ||||||||
| Input Power | 167 | KW | ||||||||
| Resolution | 100ms | |||||||||
| Voltage | Range | 2500mV~500V | ||||||||
| Accuracy | ± 0.1% of FS | |||||||||
| Stability | ±0.1% of FS | |||||||||
| Current | Range | Charge: 15A~300A Discharge: 15A~300A | ||||||||
| Accuracy | ±0.1% of FS | |||||||||
| Stability | ± 0.1% of FS | |||||||||
| Power | Output Power Per Channel | 150KW | ||||||||
| Stability | ±0.2% of FS | |||||||||
| Time | Rise Time | 10ms(10%FS~90%FS) | ||||||||
| Step Time | ≤ (365*24) hours/step | Time Format 00:00:00:00 (h:min:s:ms) | ||||||||
| Aux Channel (optional ) | Aux Input | Temperature,Voltage | ||||||||
| Temperature Range | -25ºC~110ºC | |||||||||
| Temperature Accuracy | ±1ºC | |||||||||
| Temperature Resolution | 0.1ºC | |||||||||
| Voltage Range | -5v~5v | |||||||||
| Voltage Accuracy | ± 0.1% of FS | |||||||||
| Data Acquisition | Intervals | Time Interval Δt: (1s~60000s) | ||||||||
| Voltage Interval ΔU: (25V~500V) | ||||||||||
| Current Interval ΔI: (15A~300A) | ||||||||||
| Frequency | 10Hz | |||||||||
| Charge | Modes of Operation | CCC, CVC, CC&CVC | ||||||||
| End Conditions | Main Channel: Voltage, Current, Test Time, Capacity | |||||||||
| Aux Channels: Temperature,Voltage | ||||||||||
| Discharge | Modes of Operation | CCD, CPD | ||||||||
| End Conditions | Main Channel: Voltage, Current, Test Time, Capacity | |||||||||
| Aux Channels: Temperature,Voltage | ||||||||||
| Cycle | Cycles | 1~65535 | ||||||||
| Steps | 254 | |||||||||
| Nested Function | Max three levels of loops | |||||||||
| Protective Function | Power-off data protection | |||||||||
| Off-line Operating | ||||||||||
| Main Channels: user-defined safety (upper and lower) tolerance of current, voltage and delay time | ||||||||||
| User-defined safety (upper and lower) tolerance of temperature and voltage | ||||||||||
| Channel Features | Independent pairs of closed loop for constant current source and constant voltage source | |||||||||
| Energy Regeneration | Regenerative Discharge Energy to Power Grid | |||||||||
| Channels | Independent control | |||||||||
| Noise Density | <85dB | |||||||||
| Data Management | MYSQL Database | |||||||||
| Communication Protocol | TCP/IP | |||||||||
| Export Formats | EXCEL, TXT, Graph | |||||||||
| Communication Interface | Ethernet port | |||||||||
| | ||||||||||
| Description | Product Specification | |||||||||
| Number of Channels Per Cabinet | 1 | |||||||||
| Assignable Aux Voltage Per Channel | Max 248 | |||||||||
| Assignable Aux Voltage Per Channel | Max 248 | |||||||||
| Dimensions W*D*H (mm) | 1350*733*1800 | |||||||||
| Operating Environment |