Aluminium Steel Core Overhead Insulated Cable(High Voltage)
No. | Type Specification | Conductor size n/mm | Conductor approx. Outside Diameter mm | Inner shield thickness mm | Insulation thickness mm | Outside diameter of cable mm | Bending radius | Cable weight kg/km | MΩ MΩ·km | DC resistance at 20℃ ≤Ω/km | Rated tensile strength≥N | soak for one hour, withstand voltage kV | Allowable ampacity A | |
Laying | runing | |||||||||||||
1 | JKLGYJ-10/2 | 6/1.50+1/1.50 | 3.80 | 0.80 | 3.40 | 12.20 | 244 | 268 | 144.7 | 1500 | 3.080 | 3700 | 18 | 56 |
2 | JKLGYJ-16/3 | 6/1.85+1/1.85 | 4.80 | 0.80 | 3.40 | 13.20 | 264 | 290 | 177.0 | 1500 | 1.910 | 5517 | 18 | 87 |
3 | JKLGYJ-25/4 | 6/2.32+1/2.32 | 6.30 | 0.80 | 3.40 | 14.70 | 294 | 323 | 235.5 | 1500 | 1.200 | 8360 | 18 | 118 |
4 | JKLGYJ-35/6 | 6/2.72+1/2.72 | 7.40 | 0.80 | 3.40 | 15.80 | 316 | 350 | 279.4 | 1500 | 0.968 | 11990 | 18 | 149 |
5 | JKLGYJ-50/8 | 6/3.20+1/3.20 | 8.60 | 0.80 | 3.40 | 17.00 | 340 | 374 | 354.7 | 1500 | 0.641 | 16320 | 18 | 180 |
6 | JKLGYJ-50/30 | 12/2.32+7/2.32 | 10.80 | 0.80 | 3.40 | 19.20 | 384 | 422 | 553.8 | 1500 | 0.641 | 10500 | 18 | 180 |
7 | JKLGYJ-70/10 | 6/3.80+1/3.80 | 10.80 | 0.80 | 3.40 | 19.20 | 384 | 422 | 462.8 | 1500 | 0.443 | 22220 | 18 | 226 |
8 | JKLGYJ-70/40 | 12/2.72+7/2.72 | 12.60 | 0.80 | 3.40 | 21.00 | 420 | 462 | 714.2 | 1500 | 0.443 | 55390 | 18 | 226 |
9 | JKLGYJ-95/15 | 26/2.15+7/1.67 | 12.50 | 0.80 | 3.40 | 20.90 | 418 | 460 | 592.5 | 1500 | 0.320 | 33250 | 18 | 276 |
10 | JKLGYJ-95/20 | 7/4.16+7/1.85 | 13.00 | 0.80 | 3.40 | 21.40 | 428 | 471 | 621.5 | 1500 | 0.320 | 35340 | 18 | 276 |
11 | JKLGYJ-95/55 | 12/3.20+7/3.20 | 15.20 | 0.80 | 3.40 | 23.60 | 472 | 520 | 949.5 | 1500 | 0.320 | 74200 | 18 | 276 |
12 | JKLGYJ-120/20 | 26/2.38+7/1.85 | 13.80 | 0.80 | 3.40 | 22.40 | 448 | 493 | 697.7 | 1500 | 0.253 | 38950 | 18 | 320 |
13 | JKLGYJ-120/25 | 7/4.72+7/2.10 | 14.80 | 0.80 | 3.40 | 23.20 | 464 | 510 | 1164.1 | 1500 | 0.253 | 45480 | 18 | 320 |
14 | JKLGYJ-120/70 | 12/3.60+7/3.60 | 17.00 | 0.80 | 3.40 | 25.40 | 508 | 560 | 1162.1 | 1500 | 0.253 | 95450 | 18 | 320 |
15 | JKLGYJ-150/8 | 18/3.20+1/3.20 | 14.50 | 0.80 | 3.40 | 22.90 | 458 | 503 | 698.7 | 1500 | 0.206 | 31220 | 18 | 366 |
16 | JKLGYJ-150/20 | 24/2.78+7/1.85 | 15.20 | 0.80 | 3.40 | 23.60 | 472 | 520 | 797.4 | 1500 | 0.206 | 44300 | 18 | 366 |
17 | JKLGYJ-150/25 | 26/2.70+7/2.10 | 15.50 | 0.80 | 3.40 | 23.90 | 478 | 526 | 849.9 | 1500 | 0.206 | 51400 | 18 | 366 |
18 | JKLGYJ-150/35 | 30/2.50+7/2.50 | 15.80 | 0.80 | 3.40 | 24.20 | 484 | 532 | 927.6 | 1500 | 0.206 | 61770 | 18 | 366 |
19 | JKLGYJ-185/25 | 24/3.15+7/2.10 | 17.10 | 0.80 | 3.40 | 25.20 | 504 | 554 | 946.5 | 1500 | 0.164 | 56450 | 18 | 423 |
20 | JKLGYJ-185/30 | 26/2.98+7/2.32 | 17.50 | 0.80 | 3.40 | 25.90 | 518 | 570 | 1013.3 | 1500 | 0.164 | 61100 | 18 | 423 |
21 | JKLGYJ-185/45 | 30/2.80+7/2.80 | 18.00 | 0.80 | 3.40 | 26.40 | 528 | 581 | 1130.8 | 1500 | 0.164 | 76180 | 18 | 423 |
22 | JKLGYJ-240/30 | 24/3.60+7/2.40 | 20.00 | 0.80 | 3.40 | 28.40 | 568 | 625 | 1234.4 | 1500 | 0.125 | 71840 | 18 | 503 |
23 | JKLGYJ-240/40 | 26/3.42+7/2.66 | 20.00 | 0.80 | 3.40 | 28.40 | 568 | 625 | 1280.7 | 1500 | 0.125 | 79200 | 18 | 503 |
24 | JKLGYJ-300/40 | 24/3.99+7/2.66 | 23.00 | 0.80 | 3.40 | 31.40 | 628 | 691 | 1459.1 | 1500 | 0.100 | 83000 | 18 | 583 |
No. | Type Specification | Conductor size n/mm | Conductor approx. Outside Diameter mm | Inner shield thickness mm | Outside diameter of cable mm | Bending radius | Cable weight kg/km | Ω MΩ·km | DC resistance at 20℃ ≤Ω/km | Rated tensile strength≥N | soak for one hour, withstand voltage kV | Allowable ampacity A | |
Laying | running | ||||||||||||
1 | JKLGYJ-10/2 | 6/1.50+1/1.50 | 3.80 | 2.50 | 8.80 | 196 | 216 | 89.4 | 1000 | 3.080 | 3700 | 18 | 56 |
2 | JKLGYJ-16/3 | 6/1.85+1/1.85 | 4.80 | 2.50 | 9.80 | 196 | 216 | 120.8 | 1000 | 1.910 | 5517 | 18 | 87 |
3 | JKLGYJ-25/4 | 6/2.32+1/2.32 | 6.30 | 2.50 | 11.30 | 226 | 250 | 166.2 | 1000 | 1.200 | 8360 | 18 | 118 |
4 | JKLGYJ/Q-35/6 | 6/2.72+1/2.72 | 7.40 | 2.50 | 12.40 | 248 | 272.8 | 212.8 | 1000 | 0.968 | 11990 | 12 | 149 |
5 | JKLGYJ/Q-50/8 | 6/3.20+1/3.20 | 8.60 | 2.50 | 13.60 | 272 | 299.2 | 283.0 | 1000 | 0.641 | 16320 | 12 | 180 |
6 | JKLGYJ/Q-50/30 | 12/2.32+7/2.32 | 10.80 | 2.50 | 15.80 | 316 | 347.6 | 467.3 | 1000 | 0.641 | 10500 | 12 | 180 |
7 | JKLGYJ/Q-70/10 | 6/3.80+1/3.80 | 10.80 | 2.50 | 15.80 | 316 | 347.6 | 381.8 | 1000 | 0.443 | 22220 | 12 | 226 |
8 | JKLGYJ/Q-70/40 | 12/2.72+7/2.72 | 12.60 | 2.50 | 17.60 | 352 | 387.2 | 619.5 | 1000 | 0.443 | 55390 | 12 | 226 |
9 | JKLGYJ/Q-95/15 | 26/2.15+7/1.67 | 12.50 | 2.50 | 17.50 | 350 | 385 | 487.7 | 1000 | 0.320 | 33250 | 12 | 276 |
10 | JKLGYJ/Q-95/20 | 7/4.16+7/1.85 | 13.00 | 2.50 | 18.00 | 360 | 396 | 523.3 | 1000 | 0.320 | 35340 | 12 | 276 |
11 | JKLGYJ/Q-95/55 | 12/3.20+7/3.20 | 15.20 | 2.50 | 20.20 | 404 | 444.4 | 835.0 | 1000 | 0.320 | 74200 | 12 | 276 |
12 | JKLGYJ/Q-120/20 | 26/2.38+7/1.85 | 13.80 | 2.50 | 18.80 | 376 | 413.6 | 586.0 | 1000 | 0.253 | 38950 | 12 | 320 |
13 | JKLGYJ/Q-120/25 | 7/4.72+7/2.10 | 14.80 | 2.50 | 19.80 | 396 | 435.6 | 654.5 | 1000 | 0.253 | 45480 | 12 | 320 |
14 | JKLGYJ/Q-120/70 | 12/3.60+7/3.60 | 17.00 | 2.50 | 22.00 | 440 | 484 | 1039.3 | 1000 | 0.253 | 95450 | 12 | 320 |
15 | JKLGYJ/Q-150/8 | 18/3.20+1/3.20 | 14.50 | 2.50 | 19.50 | 390 | 429 | 588.0 | 1000 | 0.206 | 31220 | 12 | 366 |
16 | JKLGYJ/Q-150/20 | 24/2.78+7/1.85 | 15.20 | 2.50 | 20.20 | 404 | 444.4 | 679.0 | 1000 | 0.206 | 44300 | 12 | 366 |
17 | JKLGYJ/Q-150/25 | 26/2.70+7/2.10 | 15.50 | 2.50 | 20.50 | 410 | 451 | 729.6 | 1000 | 0.206 | 51400 | 12 | 366 |
18 | JKLGYJ/Q-150/35 | 30/2.50+7/2.50 | 15.80 | 2.50 | 20.80 | 416 | 457.6 | 804.7 | 1000 | 0.206 | 61770 | 12 | 366 |
19 | JKLGYJ/Q-185/25 | 24/3.15+7/2.10 | 17.10 | 2.50 | 22.10 | 442 | 486.2 | 818.8 | 1000 | 0.164 | 56450 | 12 | 423 |
20 | JKLGYJ/Q-185/30 | 26/2.98+7/2.32 | 17.50 | 2.50 | 22.50 | 450 | 495 | 882.8 | 1000 | 0.164 | 61100 | 12 | 423 |
21 | JKLGYJ/Q-185/45 | 30/2.80+7/2.80 | 18.00 | 2.50 | 23.00 | 460 | 506 | 996.5 | 1000 | 0.164 | 76180 | 12 | 423 |
22 | JKLGYJ/Q-240/30 | 24/3.60+7/2.40 | 20.00 | 2.50 | 25.00 | 500 | 550 | 1092.6 | 1000 | 0.125 | 71840 | 12 | 503 |
23 | JKLGYJ/Q-240/40 | 26/3.42+7/2.66 | 20.00 | 2.50 | 25.00 | 500 | 550 | 1138.1 | 1000 | 0.125 | 79200 | 12 | 503 |
24 | JKLGYJ/Q-300/40 | 24/3.99+7/2.66 | 23.00 | 2.50 | 28.00 | 560 | 616 | 1327.3 | 1000 | 0.100 | 83000 | 12 | 583 |
Quick Information Brand Name:feiniu Place of Origin:China Model Number :05 Application :Industrial Conductor Material :Aluminum Insulation Material :PVC Jacket :PVC Type :Low Voltage Description Aluminium Steel Core Overhead Insulated Cable(Low Voltage) Aluminium steel core ...
Quick Information Brand Name:feiniu Place of Origin:China Model Number :03 Application :Industrial Conductor Material :Aluminum Insulation Material :PVC Type :Low Voltage Description Aluminium Overhead Insulated Cable(Low Voltage) Aluminium overhead insulated cable(low voltage) ...
Quick Information Brand Name:feiniu Place of Origin:China Model Number :02 Application :Industrial Conductor Material :Aluminum Insulation Material :PVC Type :High Voltage Description Aluminium Overhead Insulated Cable(High Voltage) Aluminium overhead insulated cable(high ...
High Quality Multi-Core XLPE Insulated PVC sheathed Shielded Flexible Control Cable power cable with PVC(XLPE)insulated steel wire armoured PVC sheathed 1) The long-term working tempeture of cable should be not higher than 70 degree. 2) When core is in short-circuit (Max. 5s), ...
Number of Cores and Nominal Area of Conductor Thickness of insulation (Nom) Armour wire diameter Thickness of outer sheath (minimum) Approx. Overall diameter Total weight approx. Maximum DC resistance of conductor at ...
Jacket:PVC Conductor Material:Copper Application:Underground Type:Medium Voltage Insulation Material:XLPE Model Number:YJV Brand Name:Hua-Fei Cable Place of Origin:China (Mainland) The flame retardant cables of this series are designed for high cabling density and strict fire ...
Place of Origin:China (Mainland) The product is used in aerial electric circuit at AC rated voltage U(Um)=10(12)KV. ...
Number of Cores and Nominal Area of Conductor Thickness of insulation (Nominal) Thickness of inner sheath (Minimum ) Armour wire diameter or steel strips (Dimensions) Thickness of outer sheath (minimum) Approx. Overall (diameter) Total weight approx. Maximum DC resistance of ...
Construction Standards Conductor: Solid or stranded copper NFC 32-322 Insulation: XLPE TS IEC 60502-1 Filler: PVC BS 5467 Armour: Galvanized round steel wire IEC 60502-1 Outher Sheath: PVC ...