A:Brief description:
DSHD-261A Automatic Pensky-Martens Closed Cup Flash Point Tester is designed according industrial standard SH/T0315 Technical Specifications of Closed Cup Flash Point Tester.
The main function ofDSHD-261A Automatic Pensky-Martens Closed Cup Flash Point Tester is to make determination of closed cup flash point of the petroleum products according to national standard GB/T 261 or ASTM D93.
B:Main advantages:
1. Simulation tracking displays function curves of heating up and test time.
2. Equipped with the English prompt function of mis-operation.
3. Equipped with prompt function of test date,test time and other parameters.
4. Automatically calibrate the effect of atmospheric pressure to test and calculate the corrected value.
5. Differential coefficient detection.Automatically correct the system deviation.
6. Automatically open the lid,detect the flash point and print test data.
7. The test arm rises up and lowers down automatically.
8. Igniting with electric igniting gun,forced air cooling.
C: Main technical specifications and parameters
1. Power supply:AC(220±10%)V, 50Hz.
2. Temperature measuring:Measuring range: Room temperature-250°C.
Range of flash point: 41°C-250°C.
Flash point no more than104°C: Error 2°C.
Flash point>104°C: Error 6°C.
Resolution: 0.1°C.
Accuracy: 0.5%.
3. Basic parameters:Heating rate: Correspond with GB/T261
Igniting mode: Electric ignition(Gas flame 3mm-4mm)
4. Ambient temperature: no more than 40°C
5. Relative humidity: no more than 80%
6. Power consumption of overall unit: no more than 350W
D:More Open Cup flash point tester:
DSHD-261 Pensky-Martens Closed Cup Flash Point Tester
DSHD-261-1 Pensky-Martens Closed Cup Flash Point Tester
DSHD-261A Automatic Pensky-Martens Closed Cup Flash Point Tester
DSHD-261D Fully-automatic Pensky-Martens Closed Cup Flash Point Tester
DSHD-5208 Rapid Closed Cup Flash Point Tester
DSHD-5208A Rapid High-temperature Closed Cup Flash Point Tester
DSHD-5208D Rapid Low-temperature Closed Cup Flash Point Tester
A:Brief description: DSHD-5208 Rapid Closed Cup Flash Point Tester is manufactured as per GB/T 5208-2008 Determination of flash point - Rapid equilibrium closed cup method. DSHD-5208 Rapid Closed Cup Flash Point Tester Conforms tothe requirements of rapid ...
A:Brief description: DSHD-261-1 Pensky-Martens Closed Cup Flash Point Tester is manufactured as per standards GB/T 261-2008 Determination of Flash Point(Pensky-Martens Closed Cup) and ASTM D93. DSHD-261-1 Pensky-Martens Closed Cup Flash Point Tester issuitable to make ...
A:Brief description: DSHD-261D Fully-automatic Pensky-Martens Closed Cup Flash Point Tester is designed accordingthe standards GB/T261-2008 Test Method for Flash Point of Petroleum Products by the Pensky-Martens Closed Cup Method and ASTM D93. Its function isto ...
A:Brief description: DSHD-3536A Automatic Cleveland Open Cup Flash point tester is designed according the standards GB/T3536-2008 Test Method for Flash Point and Fire Point of Petroleum Products - Cleveland Open Cup Method, ASTM D92 and ISO 2592. DSHD-3536A Automatic ...
Ⅰ.Introduction GD-3536D ASTM D92 Fully-Automatic cleveland Open Cup Flash Point Tester is designed and made as per the National Standard of People’s Republic of China GB/T3536 “Test Methods for Flash Point and Fire Point of Petroleum Products (Cleveland Open Cup ...
Summary This instrument is designed and made as per GB/T 5208-2008 Determination of flash point - Rapid equilibrium closed cup method. It can meet the requirements of rapid determination for closed cup flash point of petroleum products in oil,chemical, varnish, paint, railway, ...
Introduction This instrument is designed and made as per GB/T3536-2008 Petroleum Products - Determination of Flash and Fire Points - Cleveland open cup method and ASTM D 92 Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester. It is applicable to all ...
A:Brief description: DSHD-5208D Rapid Low-temperature Closed Cup Flash Point Tester is designed according GB/T 5208-2008 Determination of flash point - Rapid equilibrium closed cup method. DSHD-5208D Rapid Low-temperature Closed Cup Flash Point Tester is suitable to determine ...
A:Brief description: DSHD-5208A Rapid High-temperature Closed Cup Flash Point Tester is designed according GB/T 5208-2008 Determination of flash point - Rapid equilibrium closed cup method. DSHD-5208A Rapid High-temperature Closed Cup Flash Point Tester is suitable to determine ...