Window film meter LS160A

Dimension 93mm *52mm *25m (L*W*H) Weight 70g (exclude batteries) Maximum sample thickness Resolution 0.1% Accuracy ±2%(Colorless and transparent material) Visible light 530nm UV Peak wavelength 365nm IR Peak wavelength 1400nm Battery 4*AAA alkaline battery Linshang portable tran

linshangtech      [2020-12-17 10:07:54 ]

Window tint meter LS160

Size 93mm *52mm *25m (L*W*H) Weight 70g (exclude batteries) Maximum sample thickness Resolution 0.1% Accuracy ±2%(Colorless and transparent material) Visible light 530nm UV Peak wavelength 365nm IR Peak wavelength 940nm Battery 4*AAA alkaline battery LS160 transmission meter is

linshangtech      [2020-12-17 10:05:46 ]

Window film meter LS162A

UV peak wavelength 365nm IR peak wavelength 1400nm Visible light 380nm-760nm full wavelength, in line with CIE photopic luminosity function Resolution 0.1% Measurement accuracy better than ± 2% (colorless and uniform transparent material) Maximum sample thickness Weight about 16

linshangtech      [2020-12-17 10:03:36 ]

Window film meter LS180

UV peak wavelength 365nm IR peak wavelength 1400nm Visible light 550nm Resolution 0.1% Measurement accuracy 0.1% Test card slot better than ± 2% (colorless and uniform transparent material) weight about 590g Dimension 216mm × 134mm × 29mm (L*H*W) Power supply 5V AC/DC Adapter

linshangtech      [2020-12-17 09:55:22 ]

Window film transmission meter LS182

UV peak wavelength 365nm IR peak wavelength 940nm, 1400nm, Full IR and SHGC Visible light peak wavelength 380-760nm Resolution 0.1% Measurement accuracy better than ± 2% (colorless and uniform transparent material) Test card slot 47mm×91mm (W*H) Weight about 590g Dimension 216m

linshangtech      [2020-12-17 09:53:20 ]

Split window film meter LS110H

UV peak wavelength 365nm Visible light peak wavelength 380-760nm IR peak wavelength 1400nm Resolution When the measured value is the resolution is 0.1%; for other ranges, the resolution is 1% Measurement accuracy better than ± 2% (colorless and uniform transparent materials) Tes

linshangtech      [2020-12-17 09:50:32 ]

Window film meter LS101

Size 175mm*120mm*30mm (L*W*H) Test slot 20mm * 70 mm (W*H) Weight 360g Resolution 0.1% Accuracy ±2% (Colorless and transparent material) UV Peak wavelength 365nm Visible light 380-760nm, conforming to the CIE photopic luminosity function IR Peak wavelength 940nm Power Supply 4*A

linshangtech      [2020-12-17 09:46:04 ]

Tint tester LS163A

UV Peak wavelength 365nm IR Peak wavelength 1400nm Visible light 380-760nm, conform to the CIE photopic luminosity function Accuracy ±2% (Colorless and transparent material) Resolution 0.1% Test Slot 6mm *58mm (W*D) Dimension 146 mm ×73 mm ×24 mm (L*W*H) Display 128*128 Dot ma

linshangtech      [2020-12-17 09:43:36 ]

Tint testser LS163

UV Peak wavelength 365nm IR Peak wavelength 940nm Visible light 380-760nm, conform to the CIE photopic luminosity function Accuracy ±2% (Colorless and transparent material) Resolution 0.1% Test Slot 6mm * 58mm (W*D) Dimension 146 mm ×73 mm ×24 mm (L*W*H) Display 128*128 Dot ma

linshangtech      [2020-12-17 09:41:23 ]

LS171 color difference meter

Illumination geometry D/8, Specular Component Include (SCI) Illumination light source Full spectrum LED light source Measuring aperture 8mm Measurement conditions Light source D65, field of view 10° Measuring time about 1s Color spaces CIE Lab, Luv, LCh, Yxy, CMYK, RGB, Hex Colo

linshangtech      [2020-12-17 09:37:38 ]

LS170 color difference meter

Illumination geometry 45/0 (45°annular illumination, 0° viewing angle) Illumination light source Full spectrum LED light source Measuring aperture 8mm Measurement conditions Light source D65, field of view 10° Measuring time about 1s Color space CIE Lab, Luv, LCh, Yxy, CMYK, R

linshangtech      [2020-12-17 09:35:01 ]

UV meter LS125+UVALED-X0

Parameters UVALED-X0 Probe Spectral response 340nm-420nm, calibrated with 395nm UV LED Power measuring range 0 - 20000mW / cm² Resolution 1mW / cm² Energy measuring range 0-9999999mJ/ cm² Record time 0-99999s Measuring accuracy ±10% Sampling speed 2048 times/second Optional u

linshangtech      [2020-12-15 09:35:06 ]

UVA intensity meter LS125+UVA-X1

Parameters UVA-X1 Probe Spectral response Spectral response 260nm-400nm, λp = 365nm Power measuring range 0 - 200000μW/cm² Resolution 0.1μW/cm² Energy measuring range 0-9999999μJ/cm² Record time 0-99999s Measuring accuracy ±10% Sampling speed 6 times/second Optional unit

linshangtech      [2020-12-15 09:31:56 ]

UV intensity meter LS125+UVA-X0

Parameters UVA-X0 Probe Spectral response 315nm-400nm, λp = 365nm Power measuring range 0 - 2000mW / cm² Resolution 0.1mW / cm² Energy measuring range 0-9999999mJ/cm² Record time 0-99999s Measuring accuracy ±10% Sampling speed 2048 times/second Optional unit mW / cm² (defau

linshangtech      [2020-12-15 09:26:51 ]

UV intensity meter LS125+UVB-X0

Parameters UVB-X0 Probe Spectral response 280-315nm,suitable for UVB light source 297nm, 308nm, 313nm etc. Power measuring range 0 - 200000μW/cm² Resolution 0.1μW/cm² Energy measuring range 0-9999999μJ/cm2 Record time 0-99999s Measuring accuracy ±10% Sampling speed 6 times/

linshangtech      [2020-12-15 09:20:35 ]

UV intensity meter LS125+UVCLED-X0

Parameters UVCLED-X0 Probe Spectral response 240nm-320nm, suitable for testing 260nm-285nm sterilization UV LED Power measuring range 0 - 200000μW / cm² Resolution 0.1μW / cm² Energy measuring range 0-9999999μJ/cm² Record time 0-99999s Measuring accuracy ±10% Sampling spee

linshangtech      [2020-12-15 09:18:33 ]

UV intensity meter LS125+UVCWP-X1

UV intensity meter technical parameters Parameters UVCWP-X1 Probe Spectral response 230nm-280nm, λp = 254nm Power measuring range 0 - 200000μW / cm² Resolution 0.1μW / cm² Energy measuring range 0-9999999μJ/cm² Record time 0-99999s Measuring accuracy ±10% Sampling speed 6

linshangtech      [2020-12-15 09:16:50 ]

UV intensity meter LS125+UVC-X0

Ultraviolet disinfection and sterilization are widely used in hospitals, disease control centers, pharmaceutical factories, food factories, schools, nurseries, cinemas, buses, offices, homes, etc. It can purify the air and prevent bacteria from spreading through the air or passin

linshangtech      [2020-12-15 09:14:38 ]

UVA intensity meter

Parameters LS126A UV Light Meter Spectral response 340nm-420nm, calibrated with 395nm UV LED light source Power measuring range 0 - 20000 mW/cm² Resolution 1 mW/cm² Energy measuring range 0-9999999mJ/cm2 Record time 0-99999s Accuracy ±10 % Sampling speed 2048times/second Optio

linshangtech      [2020-12-15 09:04:08 ]

UVC meter LS126C

Parameters LS126C UV Light Meter Spectral response 230nm-280nm, λp = 254nm Measuring range 0 - 20000 μW / cm² Resolution 0.1μW / cm² Measuring accuracy ±10% Power value storage interval 1s/10s/60s optional Recording period 10 min / 100 min / 600 min Bluetooth transmission d

linshangtech      [2020-12-15 09:01:51 ]