P olariscope detecting stress in glass and Quartz products (Ref. PSV-413) Function 1. Observe stress distribution in transparent plastic , glass products and optical crystals 2. Measure retardation caused by internal stress in glass products Detecting object 1. transparent glass
Suzhou PTC Optical Instrument Co., Ltd [2020-12-18 13:13:20 ]
Spectral range 380nm-760nm full wavelength, in line with CIE photopic luminosity function Measurement accuracy better than ± 2% (colorless and uniform transparent materials) Resolution When the measured value is the resolution is 0.1%; for other ranges,the resolution is 1% Test
linshangtech [2020-12-17 10:24:53 ]
Light transmittance measurement accuracy ±1% (0%-50%) ±2% (50%-100%) Light transmittance resolution 0.0005% (0%-10%) 0.005% (10% -100%) Optical density measurement range 0.000OD-6.000OD Optical density measurement accuracy ±0.02 (0-2.00OD) ±2% (2.00-6.00OD) Optical density re
linshangtech [2020-12-17 10:23:08 ]
Light source 380nm-760nm full wavelength, in line with CIE photopic luminosity function Measurement accuracy better than ± 1% (colorless and uniform transparent materials) Resolution 0.001% (0% --- 10%); 0.01% (10% --- 100%) Test sample thickness Test sample diameter 10mm Weight
linshangtech [2020-12-17 10:21:32 ]
Dimension 93mm *52mm *25m (L*W*H) Weight 70g (exclude batteries) Maximum sample thickness Resolution 0.1% Accuracy ±2%(Colorless and transparent material) Visible light 530nm UV Peak wavelength 365nm IR Peak wavelength 1400nm Battery 4*AAA alkaline battery Linshang portable tran
linshangtech [2020-12-17 10:07:54 ]
Size 93mm *52mm *25m (L*W*H) Weight 70g (exclude batteries) Maximum sample thickness Resolution 0.1% Accuracy ±2%(Colorless and transparent material) Visible light 530nm UV Peak wavelength 365nm IR Peak wavelength 940nm Battery 4*AAA alkaline battery LS160 transmission meter is
linshangtech [2020-12-17 10:05:46 ]
UV peak wavelength 365nm IR peak wavelength 1400nm Visible light 380nm-760nm full wavelength, in line with CIE photopic luminosity function Resolution 0.1% Measurement accuracy better than ± 2% (colorless and uniform transparent material) Maximum sample thickness Weight about 16
linshangtech [2020-12-17 10:03:36 ]
UV peak wavelength 365nm IR peak wavelength 1400nm Visible light 550nm Resolution 0.1% Measurement accuracy 0.1% Test card slot better than ± 2% (colorless and uniform transparent material) weight about 590g Dimension 216mm × 134mm × 29mm (L*H*W) Power supply 5V AC/DC Adapter
linshangtech [2020-12-17 09:55:22 ]
UV peak wavelength 365nm IR peak wavelength 940nm, 1400nm, Full IR and SHGC Visible light peak wavelength 380-760nm Resolution 0.1% Measurement accuracy better than ± 2% (colorless and uniform transparent material) Test card slot 47mm×91mm (W*H) Weight about 590g Dimension 216m
linshangtech [2020-12-17 09:53:20 ]
UV peak wavelength 365nm Visible light peak wavelength 380-760nm IR peak wavelength 1400nm Resolution When the measured value is the resolution is 0.1%; for other ranges, the resolution is 1% Measurement accuracy better than ± 2% (colorless and uniform transparent materials) Tes
linshangtech [2020-12-17 09:50:32 ]
Size 175mm*120mm*30mm (L*W*H) Test slot 20mm * 70 mm (W*H) Weight 360g Resolution 0.1% Accuracy ±2% (Colorless and transparent material) UV Peak wavelength 365nm Visible light 380-760nm, conforming to the CIE photopic luminosity function IR Peak wavelength 940nm Power Supply 4*A
linshangtech [2020-12-17 09:46:04 ]
UV Peak wavelength 365nm IR Peak wavelength 1400nm Visible light 380-760nm, conform to the CIE photopic luminosity function Accuracy ±2% (Colorless and transparent material) Resolution 0.1% Test Slot 6mm *58mm (W*D) Dimension 146 mm ×73 mm ×24 mm (L*W*H) Display 128*128 Dot ma
linshangtech [2020-12-17 09:43:36 ]
UV Peak wavelength 365nm IR Peak wavelength 940nm Visible light 380-760nm, conform to the CIE photopic luminosity function Accuracy ±2% (Colorless and transparent material) Resolution 0.1% Test Slot 6mm * 58mm (W*D) Dimension 146 mm ×73 mm ×24 mm (L*W*H) Display 128*128 Dot ma
linshangtech [2020-12-17 09:41:23 ]
Illumination geometry D/8, Specular Component Include (SCI) Illumination light source Full spectrum LED light source Measuring aperture 8mm Measurement conditions Light source D65, field of view 10° Measuring time about 1s Color spaces CIE Lab, Luv, LCh, Yxy, CMYK, RGB, Hex Colo
linshangtech [2020-12-17 09:37:38 ]
Illumination geometry 45/0 (45°annular illumination, 0° viewing angle) Illumination light source Full spectrum LED light source Measuring aperture 8mm Measurement conditions Light source D65, field of view 10° Measuring time about 1s Color space CIE Lab, Luv, LCh, Yxy, CMYK, R
linshangtech [2020-12-17 09:35:01 ]
Parameters UVALED-X0 Probe Spectral response 340nm-420nm, calibrated with 395nm UV LED Power measuring range 0 - 20000mW / cm² Resolution 1mW / cm² Energy measuring range 0-9999999mJ/ cm² Record time 0-99999s Measuring accuracy ±10% Sampling speed 2048 times/second Optional u
linshangtech [2020-12-15 09:35:06 ]
Parameters UVA-X1 Probe Spectral response Spectral response 260nm-400nm, λp = 365nm Power measuring range 0 - 200000μW/cm² Resolution 0.1μW/cm² Energy measuring range 0-9999999μJ/cm² Record time 0-99999s Measuring accuracy ±10% Sampling speed 6 times/second Optional unit
linshangtech [2020-12-15 09:31:56 ]
Parameters UVA-X0 Probe Spectral response 315nm-400nm, λp = 365nm Power measuring range 0 - 2000mW / cm² Resolution 0.1mW / cm² Energy measuring range 0-9999999mJ/cm² Record time 0-99999s Measuring accuracy ±10% Sampling speed 2048 times/second Optional unit mW / cm² (defau
linshangtech [2020-12-15 09:26:51 ]
Parameters UVB-X0 Probe Spectral response 280-315nm,suitable for UVB light source 297nm, 308nm, 313nm etc. Power measuring range 0 - 200000μW/cm² Resolution 0.1μW/cm² Energy measuring range 0-9999999μJ/cm2 Record time 0-99999s Measuring accuracy ±10% Sampling speed 6 times/
linshangtech [2020-12-15 09:20:35 ]
Parameters UVCLED-X0 Probe Spectral response 240nm-320nm, suitable for testing 260nm-285nm sterilization UV LED Power measuring range 0 - 200000μW / cm² Resolution 0.1μW / cm² Energy measuring range 0-9999999μJ/cm² Record time 0-99999s Measuring accuracy ±10% Sampling spee