WESTINGHOUSE 1C31227G01, brand new,in stock

Eddy-current transducer probe, Vibration monitoring table double channel axis vibration monitoring table C6652 Rockwell Allen-Bradley SLC500 1747/1746 series MicroLogix 1761/1763/1762/1766/1764 series CompactLogix 1769/1768 series Logix5000 1756/1789/1794/1760/1788 series PLC-5 1

Collet Automation Equipment Co, Limited.      [2020-12-21 12:03:28 ]

Computerized Polariscope Stress Magnifier to measure stress value in penicillin bottle , crystal meterial

This device automatically detects the image luminance , thereby finding the darkest point precisely . By inputting sample photoelastic constant and thickness in advance , the stress value will be calculated by the computer . In addition, Sensitive C olor method is used to clearly

Suzhou PTC Optical Instrument Co., Ltd      [2020-12-18 13:27:47 ]

Precise Polariscope lab testing instrument to measure glass temper grade

P olariscope detecting stress in glass and Quartz products (Ref. PSV-413) Function 1. Observe stress distribution in transparent plastic , glass products and optical crystals 2. Measure retardation caused by internal stress in glass products Detecting object 1. transparent glass

Suzhou PTC Optical Instrument Co., Ltd      [2020-12-18 13:13:20 ]

Handheld carriable Polariscope checking annealing in transparent glass products

The handheld Polariscope ( Ref PSV-20 2-D ) has been designed to cover a wide range of strain viewing applications. It can be applied to the quality control inspection of glass and plastics components and may be employed as a vertical or horizontal viewing instrument. Different f

Suzhou PTC Optical Instrument Co., Ltd      [2020-12-18 11:53:36 ]

Lab-used Polariscope viewing stress in transparent glass , plastic and crystal

The Polariscope ( Ref PSV-20 2 ) has been designed to observe and analyze the internal stress of transparent glass and plastic products . Valued customers Lock & Lock , Heraeus , Ferrotec Detecting object 1. transparent glass products with complex construction. such as penicill

Suzhou PTC Optical Instrument Co., Ltd      [2020-12-18 11:41:51 ]

Transmittance meter LS110

Spectral range 380nm-760nm full wavelength, in line with CIE photopic luminosity function Measurement accuracy better than ± 2% (colorless and uniform transparent materials) Resolution When the measured value is the resolution is 0.1%; for other ranges,the resolution is 1% Test

linshangtech      [2020-12-17 10:24:53 ]

Transmission densitometer LS117

Light transmittance measurement accuracy ±1% (0%-50%) ±2% (50%-100%) Light transmittance resolution 0.0005% (0%-10%) 0.005% (10% -100%) Optical density measurement range 0.000OD-6.000OD Optical density measurement accuracy ±0.02 (0-2.00OD) ±2% (2.00-6.00OD) Optical density re

linshangtech      [2020-12-17 10:23:08 ]

Light transmittance meter LS116

Light source 380nm-760nm full wavelength, in line with CIE photopic luminosity function Measurement accuracy better than ± 1% (colorless and uniform transparent materials) Resolution 0.001% (0% --- 10%); 0.01% (10% --- 100%) Test sample thickness Test sample diameter 10mm Weight

linshangtech      [2020-12-17 10:21:32 ]

Window film meter LS160A

Dimension 93mm *52mm *25m (L*W*H) Weight 70g (exclude batteries) Maximum sample thickness Resolution 0.1% Accuracy ±2%(Colorless and transparent material) Visible light 530nm UV Peak wavelength 365nm IR Peak wavelength 1400nm Battery 4*AAA alkaline battery Linshang portable tran

linshangtech      [2020-12-17 10:07:54 ]

Window tint meter LS160

Size 93mm *52mm *25m (L*W*H) Weight 70g (exclude batteries) Maximum sample thickness Resolution 0.1% Accuracy ±2%(Colorless and transparent material) Visible light 530nm UV Peak wavelength 365nm IR Peak wavelength 940nm Battery 4*AAA alkaline battery LS160 transmission meter is

linshangtech      [2020-12-17 10:05:46 ]

Window film transmission meter LS182

UV peak wavelength 365nm IR peak wavelength 940nm, 1400nm, Full IR and SHGC Visible light peak wavelength 380-760nm Resolution 0.1% Measurement accuracy better than ± 2% (colorless and uniform transparent material) Test card slot 47mm×91mm (W*H) Weight about 590g Dimension 216m

linshangtech      [2020-12-17 09:53:20 ]

Split window film meter LS110H

UV peak wavelength 365nm Visible light peak wavelength 380-760nm IR peak wavelength 1400nm Resolution When the measured value is the resolution is 0.1%; for other ranges, the resolution is 1% Measurement accuracy better than ± 2% (colorless and uniform transparent materials) Tes

linshangtech      [2020-12-17 09:50:32 ]

Split window film meter LS110A

UV peak wavelength 365nm IR peak wavelength 940nm Visible light 380-760nm, conform to CIE photopic luminosity function Resolution When the measured value is resolution is 0.1%; for other ranges, the resolution is 1% Measurement accuracy Better than ± 2% (colorless and uniform tr

linshangtech      [2020-12-17 09:48:34 ]

Tint tester LS163A

UV Peak wavelength 365nm IR Peak wavelength 1400nm Visible light 380-760nm, conform to the CIE photopic luminosity function Accuracy ±2% (Colorless and transparent material) Resolution 0.1% Test Slot 6mm *58mm (W*D) Dimension 146 mm ×73 mm ×24 mm (L*W*H) Display 128*128 Dot ma

linshangtech      [2020-12-17 09:43:36 ]

Tint testser LS163

UV Peak wavelength 365nm IR Peak wavelength 940nm Visible light 380-760nm, conform to the CIE photopic luminosity function Accuracy ±2% (Colorless and transparent material) Resolution 0.1% Test Slot 6mm * 58mm (W*D) Dimension 146 mm ×73 mm ×24 mm (L*W*H) Display 128*128 Dot ma

linshangtech      [2020-12-17 09:41:23 ]

LS171 color difference meter

Illumination geometry D/8, Specular Component Include (SCI) Illumination light source Full spectrum LED light source Measuring aperture 8mm Measurement conditions Light source D65, field of view 10° Measuring time about 1s Color spaces CIE Lab, Luv, LCh, Yxy, CMYK, RGB, Hex Colo

linshangtech      [2020-12-17 09:37:38 ]

LS170 color difference meter

Illumination geometry 45/0 (45°annular illumination, 0° viewing angle) Illumination light source Full spectrum LED light source Measuring aperture 8mm Measurement conditions Light source D65, field of view 10° Measuring time about 1s Color space CIE Lab, Luv, LCh, Yxy, CMYK, R

linshangtech      [2020-12-17 09:35:01 ]

UV meter LS125+UVALED-X0

Parameters UVALED-X0 Probe Spectral response 340nm-420nm, calibrated with 395nm UV LED Power measuring range 0 - 20000mW / cm² Resolution 1mW / cm² Energy measuring range 0-9999999mJ/ cm² Record time 0-99999s Measuring accuracy ±10% Sampling speed 2048 times/second Optional u

linshangtech      [2020-12-15 09:35:06 ]

UVA intensity meter LS125+UVA-X1

Parameters UVA-X1 Probe Spectral response Spectral response 260nm-400nm, λp = 365nm Power measuring range 0 - 200000μW/cm² Resolution 0.1μW/cm² Energy measuring range 0-9999999μJ/cm² Record time 0-99999s Measuring accuracy ±10% Sampling speed 6 times/second Optional unit

linshangtech      [2020-12-15 09:31:56 ]

UV intensity meter LS125+UVA-X0

Parameters UVA-X0 Probe Spectral response 315nm-400nm, λp = 365nm Power measuring range 0 - 2000mW / cm² Resolution 0.1mW / cm² Energy measuring range 0-9999999mJ/cm² Record time 0-99999s Measuring accuracy ±10% Sampling speed 2048 times/second Optional unit mW / cm² (defau

linshangtech      [2020-12-15 09:26:51 ]