TMM

Cat No. CSC-C0246 Description Established from the peripheral blood of a 62-year-old man with Philadelphia chromosome negative chronic myeloid leukemia (CML) in blast crisis in 1985; cells were described to be Ph-negative, BCR-ABL1-negative; cells appear to be rather a \"normal\"

Creative Bioarray      [2018-07-11 17:36:33 ]

M-07e

Cat No. CSC-C0249 Description Established from the peripheral blood of a 6-month-old girl with acute megakaryoblastic leukemia (AML M7) at diagnosis in 1987; subline of the growth factor-independent cell line M-07; M-07e cells respond proliferatively to GM-CSF, IFN-alpha, IFN-bet

Creative Bioarray      [2018-07-11 17:35:04 ]

30ml veterinary medicine packaging PE prefilled syringe

30ml veterinary medicine packaging PE prefilled syringe Capacity 30ml Certificate CE DMF and ISO Material PE,PP Color Customized Logo Customer\'s Logo Acceptable Printing Customized Packaging standard export carton or as your requriements Advantage 1.Sift the medical grade materi

CE,ISO,DMF,SGS      [2018-07-06 14:58:00 ]

60ml plastic packaging animal syringe

60ml plastic packaging animal syringe Capacity 60ml Certificate CE DMF and ISO Material PE,PP Color Customized Logo Customer\'s Logo Acceptable Printing Customized Packaging standard export carton or as your requriements Advantage 1.Sift the medical grade material 2.The syringe h

CE,ISO,DMF,SGS      [2018-07-06 14:53:39 ]

Sell BK-EBDP HEXEN 2-fdck krystal@tritrustbio.com

Email krystal@tritrustbio com SKYPE +8615511609413 or live e94652a9008c54b1 BK-EBDP HEXEN 2-fdck 4-CDC Melatonin 4-Aminoacetophenone Oxytocin 5f-mdmb2201

TriTrust Biology Technology Co.,Ltd      [2018-06-27 13:41:46 ]

AMT-1A Manual O Tabla

- Longitud 2100 ± 50 mm - Ancho 480 ± 20 mm - Altura (850-1050) ± 20mm - Pliegue de la cabecera hacia arriba ≥45 °; doblar hacia abajo ≥90 ° - Tablero plegable hacia arriba ≥80 °; doblar hacia abajo ≥30 ° - Tablero de pierna plegable hacia abajo ≥90 ° - Elevaci

ARI Medical Technology Co., Ltd.      [2018-06-24 22:41:14 ]

AMT-ZC.IIA Cama de examen

- Plegado del tablero ≥40 ° - Elevación de la mesa de cama ≥220mm - Mesa de cama más baja y más alta 510-740mm - Dimensiones del esquema 1900 * 700 mm - Acero inoxidable 304 - Motor de marca importado - Todas las acciones se ajustan con control manual

ARI Medical Technology Co., Ltd.      [2018-06-24 22:40:02 ]

AMT-D.IV Mesa de operación (Hidráulico electrico)

- Longitud 2000 ± 50 mm - Ancho 500 ± 20 mm - Altura mín. Máx . 720-1020 ± 20 mm - Trendelenburg ≥25 °; Rev-Trend ≥25 ° - Hacia la izquierda ≥18 °; Derecha ≥18 ° - Tablero de la cabeza hacia arriba ≥40 °; Hacia abajo ≥90 ° - Tablero hacia arriba ≥55 °; H

ARI Medical Technology Co., Ltd.      [2018-06-24 22:38:35 ]

AMT-D.III (Nuevo Modelo) Mesa de operación (Hidráulico electrico)

- Longitud 2050 ± 50 mm - Ancho 520 ± 20 mm - Altura mín. Máxima (730-1120) ± 20 mm - Trendelenburg ≥30 °; Rev-Trend ≥30 ° - Hacia la izquierda ≥20 °; Derecha ≥20 ° - Tablero de la cabeza hacia arriba ≥40 °; Hacia abajo ≥90 ° - Tablero hacia arriba ≥80 °

ARI Medical Technology Co., Ltd.      [2018-06-24 22:35:45 ]

AMT-D.IA Mesa de operación (Hidráulico electrico)

- Longitud 2000 ± 50 mm - Ancho 500 ± 20 mm - Altura mín. Máxima (550-850) ± 20 mm - Trendelenburg ≥20 °; Rev-Trend ≥15 ° - Hacia la izquierda ≥15 °; Derecha ≥15 ° - Pliegue de la cabecera hacia arriba ≥40 °; doblar hacia abajo ≥90 ° - Tablero plegable haci

ARI Medical Technology Co., Ltd.      [2018-06-24 22:33:16 ]

Mesa de operaciones oftalmológica ET200 + Silla de doctor eléctrico

Mesa de operaciones oftalmológica - longitud y ancho de la mesa ≥2080mm / 550 ± 20mm - Apoyacabezas (arriba / abajo) arriba≥45 ° / abajo≥90 - Placa de la pierna (arriba / abajo) arriba≥30 ° abajo≥30 ° - Placa posterior (arriba / abajo) ≥2080mm / 550 ± 20mm - Ele

ARI Medical Technology Co., Ltd.      [2018-06-24 22:31:22 ]

JY.A(manual)Mesa de operaciones universal

- Longitud 2000 ± 50 mm - Ancho 500 ± 20 mm - Altura mín. Máxima (700-950) ± 50 mm - Trendelenburg ≥20 °; Rev-Trend ≥15 ° - Hacia la izquierda ≥15 °; Derecha ≥15 ° - La cabecera dobla hacia arriba ≥30 °; doblar hacia abajo ≥90 ° - Tablero plegable hacia arr

ARI Medical Technology Co., Ltd.      [2018-06-24 22:28:47 ]

AMT-CB.II Cama médica eléctrica (Engranaje eléctrio)

- Longitud 1900 ± 50 mm - Ancho 780 ± 20 mm - Altura mín. Máxima (550-800) ± 50 mm - Trendelenburg ≥5 °; Rev-Trend ≥12 ° - Tablero trasero doblado ≥60 ° - Ajuste de la altura del tablero de pie ≥100mm - Tablero de pie hacia arriba ≥40 °; Tablero de pie hacia af

ARI Medical Technology Co., Ltd.      [2018-06-24 22:25:56 ]

YD01-4 (LED) (Common Arm)Lámpara de operación de luz fría

- Excelente luz fría adoptando LED Como fuente de luz, el pecado Aumento de Temperatura. - Excelente calidad de luz diurna y CRI Que satisfacen las Necesidades de Iluminación de los Médicos. - Larga Vida Útil La vida del LED es de 30.000 horas Hasta. - Ahorro de Energía y re

ARI Medical Technology Co., Ltd.      [2018-06-22 15:49:49 ]

YD01-1SA lámpara de operación

- YD01-1SA es luminaria quirúrgica con fuente de luz LED verticales dispersa e Iluminación ajustable. SE APLICA extensamente en la Industria, el Tratamiento medico, la Joyería, la fotografía, la Investigación Científica, etc. ACTUALMENTE, es el equipo de Iluminación Más a

ARI Medical Technology Co., Ltd.      [2018-06-22 15:47:27 ]

YD01-I (LED) Lámpara de operación de luz fría

- La lámpara de luz fría Operación de es apta para Iluminación auxiliar para Exámenes Médicos en ears, nariz, cavidad oral, Sistema urinario y ginecología. - Excelente efecto de Iluminación Sistema óptico Único, punto de luz homogéneo, Alta Definición. - Larga Vida Ú

ARI Medical Technology Co., Ltd.      [2018-06-22 15:45:58 ]

YD01-IE (LED) Lámpara de operación de emergencia de luz fría

- Iluminancia ≥ 25000Lux - Temperatura de Color 4.800 ± 500 K - Voltaje de la Fuente de Alimentación 220V / 50Hz - Potencia nominal de la bombilla 3,2 V / 1W - Poder de Importación 56VA - Bombilla bombilla LED - Vida de la bombilla LED > = 30000h - Índice de Reducción de C

ARI Medical Technology Co., Ltd.      [2018-06-22 15:43:33 ]

YD200 (LED) Lámpara de operación de luz fría (profunda)

- Iluminancia 50,000Lux - Temperatura de Color 4.800 ± 500 k - Voltaje de la Fuente de Alimentación 220V / 50Hz - Potencia nominal de la bombilla 3,2 V / 1W - Bombilla bombilla LED - Consumo de Energía en total 50W - Cantidad total de de bombilla LED 13 piezas - This lámpara

ARI Medical Technology Co., Ltd.      [2018-06-22 15:41:08 ]

YD200E (LED) (emergencia) Luz fría Lámpara de operación (profunda)

- La lámpara de luz fría Operación de AC / DC YD200E (LED) cumple con los Requisitos de Iluminación para Operaciones Quirúrgicas en Circunstancias Especiales o Donde no hay Suministro de energía. - Cuando Hay Un corte de Energía de la Red Eléctrica o por otra Alguna Razó

ARI Medical Technology Co., Ltd.      [2018-06-22 15:39:23 ]

YD200C (LED) (En techo) Lámpara de funcionamiento de luz fría (profunda)

- Iluminancia ≥25,000Lux - Temperatura de Color 4.800 ± 500 k - Voltaje de la Fuente de Alimentación 220V / 50Hz - Potencia nominal de la bombilla 3,2 V / 1WW - Bombilla bombilla LED - Altura de Instalación Más Baja 2300-2600 mm - This lámpara de ONU agujero con Profundida

ARI Medical Technology Co., Ltd.      [2018-06-22 15:37:12 ]