The case with human nature can be opened by light touch. It is convenient to apply for household. Face plate is flame-proof and anti-flaming ABS, pure ivory, high intensity, it doesn’t change color for ever, the transparent material is PC; Bottom box material is excellent cold
YUEQING YING S IMPORT EXPORT CO.,LTD [2015-02-06 23:48:12 ]
1.1Function Measure the transformer load current, load loss, short-circuit voltage, short circuit (load) losses. 1.2 Test Item RMS phase voltage Average value of three-phase AC voltage Three-phase current RMS Percentage of no-load loss and no-load current Load loss, impedance vol
重庆格纳迪机电设备有限公司 [2014-12-07 07:54:47 ]
ZM12DGGDVFD inverter control cabinet is degined according to the standard of industrial site electrical for experiments of inverter control circuit structures,powerful motor control of frequency conversion control operation,etc. Technical information 1.Power supply single phase t
润宝教育设备 [2014-06-27 02:35:29 ]
1.220kV Station Polymer surge arrester/Composite Lightning arrestor 2.Since 1993 Rated voltage 216KV Shed diameter 220/180 Height b 2560mm Gross weight 85kg Creepage distance 7812mm Long duration current impulse 800A Lightning impulse withstand 950KV Power frequency voltage withs
Hangzhou Yongde Electric Appliances Co.,Ltd. [2014-05-21 21:43:44 ]
GTB Dry-Type Experimental Transformer I Product Introduction GTB Dry Type High-voltage Testing Transformer uses advanced production equipment, and new technology of c oil winding epoxy vacuum pouring and CD-type iron core , which obviously reduce weight and volume, improve insula
ChongQing Gold Machine& Electric Equipment Co., Ltd. [2014-03-05 03:17:40 ]
Gas insulated standard capacitor is widely used for capacitance and tan delta measuring of capacitors, cables, bushings, insulators, transformer winding and other insulated materials. Also it can be used as divider at HV measuring. Under special condition, it can be used as coupl
Fivestar HV Testing Equipment Co., Limited. [2013-12-20 03:32:18 ]
CP96 meter for genset Synchroscope Meter CP 96 METER panel meter 96 clamp meter generator meter Model Number CP-96, CP-72, CFS, MFO, CA-34, CV-34 Features 1) For meter we can offer ammeters, voltmeters, hz meters, power factor meters, kw meters 2) For current transformer we can o
东莞市旷世电子有限公司 [2013-10-30 10:20:30 ]
This information is for the use of GU3310A/GU3311A controller provides fast operating guidelines, please refer to the instructions for use with standard. A controller, the size of the Size of installation hole size W120mm * H102mm * D48mm W109mm * H91mm Two, parameter setting met
东莞市旷世电子有限公司 [2013-10-29 08:57:49 ]
Item specifics is_customized Yes Brand Name woodward Model Number 8270-1029 Place of Origin China (Mainland)
东莞市旷世电子有限公司 [2013-10-29 08:36:27 ]
Voltage up to 1000kV Current up to 4A SF6 gas insulated test transformers are espencially designed for testing metal-clad switchgear (GIS) in the factory and on-site, and for testing on-site substation equipment. The conventional transformer can be flanged directly to the GIS. Th
Fivestar HV Testing Equipment Co., Limited. [2013-08-16 04:08:59 ]
Conventional AC test transformers are especially designed to testing objects of medium capacitance. These system are particularly suited for tests requiring stable voltage even if the load changes under voltage (corona, wet & pollution tests) or when the load in inductive (induct
Fivestar HV Testing Equipment Co., Limited. [2013-08-16 04:07:53 ]
Voltage 10kV - 2250kV (single unit YDTW up to 750kV, cascaded YDTCW up to 2250kV) Current 0.1A -40A The AC test transformers are especially designed for medium capacitance testing object, such as power transformers, cables, generators, motors, GIS switchgears, bushings and arrest
Fivestar HV Testing Equipment Co., Limited. [2013-08-16 04:00:42 ]
SF6 gas insulated series resonant test system is special designed for testing of gas insulation switchgear and gas insulation substations. The system can be connected with the GIS directly, which bring great convenient to the testing. Compared to oil insulated resonant system, It
Fivestar HV Testing Equipment Co., Limited. [2013-08-16 03:55:32 ]
Voltage 10kV – 600kV Current 5A – 80A Tank type AC series resonant test system is special designed for the high capacitance load, such as power cable. The huge system is suitable for testing in the factory or on-site. There are two different design variable frequency or adjus
Fivestar HV Testing Equipment Co., Limited. [2013-08-16 03:54:25 ]
Voltage up to 2000kV Current up to 40A Adjustable inductance resonant test system is designed to compensate capacitance in the testing circuit precisely by tuning inductance of the test system. The natural resonance frequency of the test system matches feed-in mains, usually 50/6
Fivestar HV Testing Equipment Co., Limited. [2013-08-16 03:50:35 ]
Brand PROMOV / TAIHANG or Equivalent Type Type 3 (Protection in accordance to EN61643-11) Model TD9-02/4 or TD9-02/8 Disch arge Current, In / Imax 2KA / 4KA Protection Level at Imax, Up L-L < 25V ; L-E < 500V Cable Speed & Insert Loss 0.72C , < 0.5 dB Response Time, Ta 2ns Temper
MOSEB Engineering Sdn Bhd [2013-07-25 05:26:02 ]
Brand PROMOV / TAIHANG or Equivalent Type Type 3 (Protection in accordance to EN61643-11 DIN VDE0675-6) Model TD1 Series (HOT PLUGGABLE FEATURE) Nominal System Voltage, Un 1 - 5V / 1 - 10V / 1 - 24V Nominal Discharge Current, In 5KA Max Discharge Current, Imax 10KA (L-L) , 20KA (
MOSEB Engineering Sdn Bhd [2013-07-25 05:25:04 ]
Brand PROMOV / TAIHANG or Equivalent Type Type 1 & 2 - Three Phase(Protection in accordance to EN61643-11) Model VB40/385/1P1 Max Continuos Voltage, Uc 385VAC Per Phase Discharge Current, In / Imax 40 / 80KA Protection Level at Imax, Up 2.3KV (
MOSEB Engineering Sdn Bhd [2013-07-25 05:23:55 ]
Brand PROMOV / TAIHANG or Equivalent Type Type 1 (Class 1) - Three Phase(Protection in accordance to EN61643-11) Model VA100/385/3P1 Max Continuos Voltage, Uc 385VAC Per Phase or 440VAC Per Phase Discharge Current, In / Imax 100/300 KA Protection Level at Imax, Up 2.5KV (
MOSEB Engineering Sdn Bhd [2013-07-25 05:23:19 ]
Brand PROMOV / TAIHANG or Equivalent Type Type 2 - Single Phase(Protection in accordance to EN61643-11) VC20/385/1P1 Model 385VAC Per Phase Max Continuos Voltage, Uc 20 / 40KA Discharge Current, In / Imax 2.0KV (
MOSEB Engineering Sdn Bhd [2013-07-25 05:21:24 ]