Fire Alarm Control Panel

What we supplied is market and enginer confirmed products ,If you still have any questions about the products, pls contact us freely,we'd like to have a further talking with you on it.any inquiry from you will be replied within 24 hoours.

The CK1000 Series Conventional Fire Alarm Control Panel is a 24 volt, four to sixteen-zone, Class B,
Conventional Fire Alarm Control Panel. Designed exclusively to meet the latest market requirements and
future ULC codes, the highly cost-effective CK1000 Series can be used in a variety of low- to mid-sized
applications.

FEATURES
Four, Eight, Sixteen Zone Style B (Class B) Initiating Device Circuits (IDCs), All zones accept
two-wire smoke detectors and any normally-open contact devices.
Two Supervisory Input with DC12V output, ideal to connect security alarm devices.
Three General Alarm, Trouble and Supervisory, Form A Relay Output.
One, Two, Four Built-in Sound Output, Style Y (Class B) Notification Appliance (Signal) Circuits
(NACs), NACs may be programmed: Silenceable or Non-Silenceable.
3.0 amps of total system power. Resettable DC24V & Non-resettable DC24V Output.
Zone Input Short Circuit can be set to Alarm or Fault mode.
RS485 Communication Port (optional).
Automatic/Manual mode can be programmed.
Disable/Enable control per Zone (IDC) can be programmed.
Disable/Enable Sound Output(NACs) can be programmed.
SPECIFICATIONS
AC POWER: 220VAC, 50 Hz.
BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for
normal flat charge. Maximum battery charger capacity: 18AH battery.
NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate
battery box.
Total DC24V system power: 3.0 amps.
Maximum current per NAC: 1.25 amps.
Maximum battery charging capability: 18 AH.
Resettable four-wire smoke detector power output.
Non-resettable power output.
Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC
(resistive), 2.0 amps @ 30 VAC (resistive).
CABINET AND MOUNTING
Cabinet physical dimensions: 40.0 cm high x 35.0 cm wide x 11.5 cm deep.
Carton package dimensions:: 48.0 cm high x 42.0 cm wide x 18.5 cm deep.
Cabinet net weight: 6.0 Kg. (without batteries).
Cabinet gross weight: 6.6 Kg. (without batteries).
Mounting: The cabinet mounts using two key slots at the top of the back and two additional
6.5mm diameter holes at the bottom.

This fire alarm control panel have 4 ZONES,8ZONES&16ZONES.
It's a market confirmed system we supplied
It has gotten good honor

  • Model Number:CK1000
  • Brand Name:SL
  • Place of Origin:Zhejiang China (Mainland)
  • Country:China (Mainland)
  • telephone:86-574-65277788
Delivery Time: 20-30days after receipt of payment
Package: standard export packing
Supply Ability: 100000 Piece/Pieces per Month
Minimum Order Quantity: 100 Piece/Pieces
Payment Terms: T/T,Western Union
Port: ningbo
Model Number: CK1000
Brand Name: SL
Place of Origin: Zhejiang China (Mainland)
*Your name:
*Your Email:
*To:Ningbo Tongxin Valve & Fitting Co., Ltd.
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters Remaining: 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

We do inquire for you , please wait ...

Fire Alarm for Energy Storage Power Station

Fire Alarm for Energy Storage Power Station Energy storage power station with fire detection devices in real time collection and the surrounding area environment temperature, concentration of carbon monoxide, hydrogen concentration and the concentration of VOC and smoke ...

Come From Sichuan Xuxin Technology Co., LTD

Fire Alarm Controller for Energy Storage Power Station

Fire Alarm Controller for Energy Storage Power Station The Fire alarm controller is set in each energy storage cabin, with alarm signal acquisition with the cabin detector, start the Fire extinguishing device, linkage alarm, linkage communication with BMS and other functions. ...

Come From Sichuan Xuxin Technology Co., LTD

6 Panel Door white Fire Rated Door

Certified up to FD120, our 6 Panel white fireproof doors gives you up to 2 hours of fire protection for your property. These steel doors are also FD30 and FD60 rated should you require certification to this level. These 6 panel 30 min fire door also feature a multi point ...

Come From ZHEJIANG XINDUO IMPORT & EXPORT CO.,LTD(SIMTO GROUP)

6 Panel Door white Fire Rated Door

Certified up to FD120, our 6 Panel white fireproof doors gives you up to 2 hours of fire protection for your property. These steel doors are also FD30 and FD60 rated should you require certification to this level. These 6 panel 30 min fire door also feature a multi point ...

Come From ZHEJIANG XINDUO IMPORT & EXPORT CO.,LTD(SIMTO GROUP)

BLIIoT Network Fault Monitoring Alarm RTU5028E Control AC Contactor

The Network Fault Monitoring RTU RTU5028E is special designed for remote monitoring Ethernet devices communication status and power supply status. It can detect the Ethernet device fault caused by power supply or network communication. If network communication fault, it can ...

Come From BLIIOT

Remote Cellular wireless 4g 8DI 2DO sms app alarm water level monitoring and control system

S150 is a cost-effective Cellular SMS Controller. The SMS controller features 8 digital inputs, 2 relay outputs, it can be connected to various detectors, such as water level detectors, door sensors, infrared detectors, temperature detectors, humidity detectors, water immersion ...

Come From BLIIOT

MAG808C 8 Zones Remote Control Panel

Features ● Network port balanced output audio ● Audio signal level indicator ● Partition source control and volume control ● With digital screen & 24VDC power supply ● MP3 play and independent volume control knob ● 1 line input and independent volume control knob ...

Come From Guangzhou DSPPA Audio Co., Ltd.

Modbus RTU RS485 to TCP SMS Phone alarm remote controller

Cellular IoT RTU S270 is a wireless industrial IoT data monitoring and remote control unit, which is an ideal solution for remote data monitoring, data acquisition, remote control, and real time alarm. The RTU features 2 digital inputs, 2 analog inputs, 2 relay outputs, 1 ...

Come From BLIIOT

Electrical Control Panel / Terminal Blocks Mounting Rail 35mm DIN Making Machine

Control Panel / Terminal Blocks Mounting Rail 35mm DIN Making Machine. Guarantee of Quality https://www.superdamc.com Superda guarantee Channel roll former line design accordance with clients required drawing, machine is brand new. Specification and performance as stipulated in ...

Come From Shenzhen Superda Machine Co.,Ltd

High reliability SMS Remote Controller Alarm Unit S130 for Remote monitoring of flammable gases

The GSM 3G 4G Remote Controller Alarm is an industrial class, high reliability, high stability Remote Control and Alarm Unit. It embedded 32-Bit High Performance Microprocessor MCU, inbuilt industrial Cellular module, provides 2 relay outputs, 2 digital inputs and USB Serial ...

Come From BLIIOT