Air-Tech's After Coolers

Air-Tech's After Coolers are specially designed for bringing down the compressed air temperature. We have a wide range of shell & tube type, water cooled, compressed air Inter / After Coolers, with delivery of most of the models available EX-STOCK. Select out of following available multi / single stage standard after coolers. All coolers are available with or without inbuilt Pulsation Dampner and /or Moisture Separator. Material of Construction Shell Pipe Carbon Steel (ERW) IS 1239/ 3589 Tubes Copper (Seamless) DHP - B-111 All others Carbon Steel IS 2062 Working Temperatures: Inlet-140 deg. Celcius, Outlet: 40 deg Celcius Air Side Working Pressure: 7.0 kg/sq.cm.g Water Qty required is given in Cu.Mtr / Hr.SINGLE STAGE AFTER COOLERSModel CFM Air Pressure Drop Passes Water Qty Overall Dimensions ATE/ 0330 0000-0040 0.02kg/cm.sq.g 1:2 02.47 170 mm x 1200 mm ATE/ 0432 0040-0130 0.15 kg/sq.cm.g 1:2 08.05 260 mm x 1500 mm ATE/ 0440 0040-0110 0.09 kg/sq.cm.g 1:2 04.08 260 mm x 1500 mm ATE/ 0453 0110-0155 0.14 kg/sq.cm.g 1:2 04.11 260 mm x 1950 mm ATE/ 0540 0155-0195 0.14 kg/sq.cm.g 1:2 06.03 260 mm x 1500 mm ATE/ 0553 0195-0260 0.14 kg/sq.cm.g 1:2 06.03 260 mm x 1950 mm ATE/ 0640 0195-0220 0.14 kg/sq.cm.g 1:2 06.81 340 mm x 1500 mm ATE/ 0653 0220-0325 0.20 kg/sq.cm.g 1:2 10.06 340 mm x 1950 mm ATE/ 0660 0325-0375 0.20 kg/sq.cm.g 1:2 11.61 340mm x 2250 mm ATE/ 0840A1 0220-0300 0.09 kg/sq.cm.g 1:4 06.96 360 mm x 1500 mm ATE/ 0840A2 0375-0475 0.14 kg/sq.cm.g 1:4 07.53 360 mm x 1500 mm ATE/ 0853 0475-0640 0.15 kg/sq.cm.g 1:4 09.90 360 mm x 1950 mm ATE/ 0860 0640-0725 0.15 kg/sq.cm.g 1:4 09.62 360 mm x 2250 mm ATE/ 0880 0725-0955 0.14 kg/sq.cm.g 1:4 11.02 360 mm x 3000 mm ATE/ 1040A1 0475-0550 0.20 kg/sq.cm.g 1:6 10.20 410 mm x 1500 mm ATE/ 1040A2 0725-0750 0.15 kg/sq.cm.g 1:6 08.71 410 mm x 1500 mm ATE/ 1053 0955-1000 0.15 kg/sq.cm.g 1:6 11.61 410 mm x 1950 mm ATE/ 1060 1000-1075 0.13 kg/sq.cm.g 1:6 13.06 410 mm x 2250 mm ATE/ 1080 1125-1350 0.13 kg/sq.cm.g 1:8 15.48 410 mm x 3000 mm ATE/ 1240 1000-1075 0.21 kg/sq.cm.g 1:8 11.09 460 mm x 1500 mm ATE/ 1253 1125-1350 0.20 kg/sq.cm.g 1:8 15.67 460 mm x 1950 mm ATE/ 1260 1500-1550 0.20 kg/sq.cm.g 1:8 18.00 460 mm x 2250 mm ATE/ 1280 1550-2100 0.21 kg/sq.cm.g 1:8 21.67 460 mm x 3000 mm ATE/ 1440 1350-1400 0.19 kg/sq.cm.g 1:8 14.45 510 mm x 1500 mm ATE/ 1453 1550-1900 0.20 kg/sq.cm.g 1:8 22.06 510 mm x 1950 mm ATE/ 1460 1900-2100 0.20 kg/sq.cm.g 1:8 24.38 510 mm x 2250 mm ATE/ 1480 2100-2700 0.21 kg/sq.cm.g 1:4 31.35 510 mm x 3000 mm ATE/ 1640 2100-2150 0.16 kg/sq.cm.g 1:6 25.00 560 mm x 1500 mm ATE/ 1653 2700-2850 0.16 kg/sq.cm.g 1:6 29.42 560 mm x 1950 mm ATE/ 1660 2850-3250 0.16 kg/sq.cm.g 1:6 30.20 560 mm x 2250 mm ATE/ 1680 3250-4100 0.17 kg/sq.cm.g 1:6 38.08 560 mm x 3000 mm MULTI STAGE AFTER COOLERSModel CFM Air Pressure Drop Passes Water Qty Overall Dimensions ATE/ 0330 0000-0040 0.03 kg/cm.sq.g 1:2 02.00 170 mm x 1200 mm ATE/ 0432 0055-0160 0.20 kg/sq.cm.g 1:2 06.00 260 mm x 1500 mm ATE/ 0440 0055-0150 0.15 kg/sq.cm.g 1:2 04.20 260 mm x 1500 mm ATE/ 0453 0150-0180 0.15 kg/sq.cm.g 1:2 03.30 260 mm x 1950 mm ATE/ 0540 0180-0225 0.15 kg/sq.cm.g 1:2 06.20 260 mm x 1500 mm ATE/ 0553 0225-0350 0.20 kg/sq.cm.g 1:2 09.70 260 mm x 1950 mm ATE/ 0640 0225-0280 0.20 kg/sq.cm.g 1:2 06.81 340 mm x 1500 mm ATE/ 0653 0280-0370 0.21 kg/sq.cm.g 1:2 08.20 340 mm x 1950 mm ATE/ 0660 0370-0430 0.20 kg/sq.cm.g 1:2 08.00 340mm x 2250 mm ATE/ 0840A1 0430-0475 0.20 kg/sq.cm.g 1:4 06.60 360 mm x 1500 mm ATE/ 0840A2 0430-0630 0.19 kg/sq.cm.g 1:4 08.76 360 mm x 1500 mm ATE/ 0853 0630-0830 0.20 kg/sq.cm.g 1:4 09.24 360 mm x 1950 mm ATE/ 0860 0830-0940 0.21 kg/sq.cm.g 1:4 08.71 360 mm x 2250 mm ATE/ 0880 0940-1250 0.20 kg/sq.cm.g 1:4 08.70 360 mm x 3000 mm ATE/ 1040A1 0430-0620 0.20 kg/sq.cm.g 1:6 06.95 410 mm x 1500 mm ATE/ 1040A2 0940-0975 0.20 kg/sq.cm.g 1:6 09.04 410 mm x 1500 mm ATE/ 1053 0975-1275 0.20 kg/sq.cm.g 1:6 08.87 410 mm x 1950 mm ATE/ 1060 1275-1475 0.20 kg/sq.cm.g 1:6 10.25 410 mm x 2250 mm ATE/ 1080 1475-2000 0.20 kg/sq.cm.g 1:8 12.36 410 mm x 3000 mm ATE/ 1240 1975-1150 0.20 kg/sq.cm.g 1:8 08.00 460 mm x 1500 mm ATE/ 1253 1475-1600 0.21 kg/sq.cm.g 1:8 11.11 460 mm x 1950 mm ATE/ 1260 1600-1850 0.21 kg/sq.cm.g 1:8 12.86 460 mm x 2250 mm ATE/ 1280 1850-2300 0.20 kg/sq.cm.g 1:8 08.00 460 mm x 3000 mm ATE/ 1440 1500-1700 0.20 kg/sq.cm.g 1:8 11.82 510 mm x 1500 mm ATE/ 1453 1700-2100 0.20 kg/sq.cm.g 1:8 14.60 510 mm x 1950 mm ATE/ 1460 2300-2350 0.20 kg/sq.cm.g 1:8 16.34 510 mm x 2250 mm ATE/ 1480 2350-3100 0.21 kg/sq.cm.g 1:4 21.56 510 mm x 3000 mm ATE/ 1640 2350-2650 0.21 kg/sq.cm.g 1:6 18.43 560 mm x 1500 mm ATE/ 1653 3100-3350 0.21 kg/sq.cm.g 1:6 23.30 560 mm x 1950 mm ATE/ 1660 3350-3750 0.21 kg/sq.cm.g 1:6 20.66 560 mm x 2250 mm ATE/ 1680 3250-4100 0.21 kg/sq.cm.g 1:6 25.27 560 mm x 3000 mm

  • Country:India
  • telephone:91-265-2313358
After Coolers (Shell -Tube Type and Finned Tube Type)
*Your name:
*Your Email:
*To:Air-Tech Engineers
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters Remaining: 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

We do inquire for you , please wait ...

KTA19-C525 after cooler cummins

Coil Number:Other Usage:Power Model Number:KTA19-C525 Brand Name:cummins KTA19-C525 after cooler cummins after cooler cummins 3001299Cummins intercooler core is used for the following Cummins engines ...

Come From Chongqing Youkang Mechanical Parts Sales Department

KTA19-C485 after cooler

Coil Number:Other Usage:Power Model Number:KTA19-C485 Brand Name:cummins KTA19-C485 after cooler after cooler 3001299Cummins intercooler core is used for the following engines: marine main machine-K ...

Come From Chongqing Youkang Mechanical Parts Sales Department

KTA19-G cummins after cooler

Coil Number:Other Usage:Power Model Number:KTA19-G Brand Name:cummins KTA19-G cummins after cooler cummins after cooler 3001299Cummins intercooler core is used for the following en ...

Come From Chongqing Youkang Mechanical Parts Sales Department