1. Product introduction
Transformer ratio meter is applied to measure the voltage ratio of three or single phase transformer. All the data and test results are shown on a 320*240 LCD screen. All the test results could be printed by the micro printer or saved in the storage of the tester. The tester has a good performance on auto protection and anti-disturb.
2. Main functions and Characters
♦ Automatically measure transformer connection group
♦ Automatically switch range
♦ Automatically measure ratio of single or three phase transformer
♦ Automatically measure ratio of single or three phase voltage transformer
♦ Automatically measure the turn ratio and polarity of single phase CT and VT
♦ Calculate ratio error automatically
♦Support YY/YD/DD/DY four connection mode in three phase transformer
♦ Testing voltages is cut off automatically when one test is finished
♦ Overload and reverse connection detect unit would prevent tester damaged in wrong connection mode.
♦ Setting data and the test results are saved automatically. The history data can be recall again.
♦Print test results by micro printer
3. Technique Index
1 The measuring range of ratio: 1-10000
2 Measuring groups: 1-12point
3Accuracy: 0.1%RGD+0.01%FS for 1-1000; 0.2%RGD+0.02%FS for 100-10000
4 Rated power supply: AC220v±10% 50/60 Hz
5 Environment temperature:-5°C--50°C
6 Environment humidity :<85%
7 Dimension: 430×320×215 mm3
8 Weight:<10kg
High accury 3-phase Power Transformer Turn Ratio Tester TTR testing Meter with Turn Ratio 1~10000 It is designed according IEC76-1 and IEC60044. It could be applied to test the turns ratio and group vector of single or three phase transformer. Also the connection group of ...
GDBC-901 Three and Single Phase Turn Ratio Meter 1. Product introduction GDBC-901 Three and Single Phase Turn Ratio Meter is applied to measure the voltage ratio of three or single phase transformer. All the data and test results are shown on a 320*240 LCD screen. All the test ...
GDBC-901 Voltage and Turn Ratio Test of Transformer 1. Product introduction GDBC-901 Voltage and Turn Ratio Test of Transformer is applied to measure the voltage ratio of three or single phase transformer. All the data and test results are shown on a 320*240 LCD screen. All the ...
It is to test voltage ratio, vector, polarity, ratio error of current transformer and voltage transformer. 1 GDBC-901 turns ratio test of transformer Functions: 1 The voltage ratio measurement for three or singe phase transformer 2 The group vector measurement for three phase ...
1 Functions 1. The voltage ratio measurement for three or singe phase transformer 2. The group vector measurement for three phase transformer. 3. The polarity measurement for single phase transformer or CT/PT 4. Voltage ratio error calculation 5. Current transformer ratio ...
I.Functions 1. The voltage ratio measurement for three or singe phase transformer 2. The group vector measurement for three phase transformer. 3. The polarity measurement for single phase transformer or CT/PT 4. Voltage ratio error calculation 5. Current transformer ratio ...