GD-261 PMCC Flash Point Tester

Place Of Origin
Chongqing of China
Packaging
Wooden Case
Delivery
7 Days

Summary
This instrument is designed and manufactured as per standards GB/T 261-2008 Determination of Flash Point - Pensky-Martens closed cup method and ASTM D93 Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester. It is used to make determination of the closed cup flash point of the petroleum products.

I. Main Technical Features
1. This instrument is designed as per GB/T261 and ASTM D93.
2. The heating power is continuously and steplessly adjustable. The power is shown visually by voltmeter.The temperature control mode is advanced and reasonable.
3. The structure is designed small and exquisite.The stainless-steel table board is beautiful and easy to clean.
4. Operation is easy.Test results are precise.It has been chosen as the instrument to test the closed cup flash point by many metering and detecting institutes.

II. Main Technical Specifications
1. Power supply:AC (220±10%)V, 50Hz.
2. Heating device::The heating power is continuously adjustable from 0 W to 600W.
3. Heating rate::(1~12)℃/min;Controllable and adjustable.
4. Stirring rate: (1) Procedure A: (90~120)RPM
(2) Procedure B: (250±10)RPM
5. Standard oil cup:(1) Inner diameter: 50.7mm~50.8mm.
(2) Depth: 55.7mm~56.0mm
(3) The scribed line depth of capacity of testing oil: 33.9mm~34.3mm.
(4) Capacity of testing oil:about 70ml
6. Igniting device: (1) Igniting source: gas(or other civilian fuels,the same below)
(2) Electric ignition. Gas flame diameter:3.2mm~4.8mm
7. Thermometers:Mercury-in-glass thermometer.Specifications are as below:
(1)Scale -5℃~110℃, division 0.5℃。
(2)Scale 20℃~150℃, division 1℃。
(3)Scale 90℃~370℃,division 2℃。
8. Ambient temperature:≤ 35℃
9. Relative humidity:≤ 85%
  • Country: China (Mainland)
  • Business Type:
  • Market:
  • Founded Year:2009
  • Address:重庆市南岸区南坪金台大厦9-10
  • Contact:Daisy Tao
more images of GD-261 PMCC Flash Point Tester
*Your name:
*Your Email:
*To:重庆格纳迪机电设备有限公司
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters : 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

submiting now We do inquire for you , please wait ...

DSHD-5208 Rapid Closed Cup Flash Point Tester
DSHD-5208 Rapid Closed Cup Flash Point Tester

A:Brief description:   DSHD-5208 Rapid Closed Cup Flash Point Tester is manufactured as per GB/T 5208-2008 Determination of flash point - Rapid equilibrium closed cup method.   DSHD-5208 Rapid Closed Cup Flash Point Tester Conforms tothe requirements of rapid ...

Dshing Instrument Co.,Ltd

DSHD-261-1 Pensky-Martens Closed Cup Flash Point Tester
DSHD-261-1 Pensky-Martens Closed Cup Flash Point Tester

A:Brief description:  DSHD-261-1 Pensky-Martens Closed Cup Flash Point Tester is manufactured as per standards GB/T 261-2008 Determination of Flash Point(Pensky-Martens Closed Cup) and ASTM D93.   DSHD-261-1 Pensky-Martens Closed Cup Flash Point Tester issuitable to make ...

Dshing Instrument Co.,Ltd

DSHD-261A Automatic Pensky-Martens Closed Cup Flash Point Tester
DSHD-261A Automatic Pensky-Martens Closed Cup Flash Point Tester

A:Brief description:  DSHD-261A Automatic Pensky-Martens Closed Cup Flash Point Tester is designed according industrial standard SH/T0315 Technical Specifications of Closed Cup Flash Point Tester.   The main function ofDSHD-261A Automatic Pensky-Martens Closed Cup Flash ...

Dshing Instrument Co.,Ltd

DSHD-261D Fully-automatic Pensky-Martens Closed Cup Flash Point Tester
DSHD-261D Fully-automatic Pensky-Martens Closed Cup Flash Point Tester

A:Brief description:  DSHD-261D Fully-automatic Pensky-Martens Closed Cup Flash Point Tester  is designed accordingthe standards GB/T261-2008 Test Method for Flash Point of Petroleum Products by the Pensky-Martens Closed Cup Method and ASTM D93.   Its function isto ...

Dshing Instrument Co.,Ltd

DSHD-3536A Automatic Cleveland Open Cup Flash point tester
DSHD-3536A Automatic Cleveland Open Cup Flash point tester

A:Brief description:  DSHD-3536A Automatic Cleveland Open Cup Flash point tester is designed according the standards GB/T3536-2008 Test Method for Flash Point and Fire Point of Petroleum Products - Cleveland Open Cup Method, ASTM D92 and ISO 2592.  DSHD-3536A Automatic ...

Dshing Instrument Co.,Ltd

DSHD-3536-1 Cleveland Open-Cup Flash Point Tester
DSHD-3536-1 Cleveland Open-Cup Flash Point Tester

A:Brief description:  DSHD-3536-1 Cleveland Open-Cup Flash Point Tester is designed according the standards GB/T3536-2008 Test Method for Flash Point and Fire Point of Petroleum Products - Cleveland Open Cup Method,ASTM D92 and ISO2592.  DSHD-3536-1 Cleveland Open-Cup Flash ...

Dshing Instrument Co.,Ltd

DSHD-3536 Cleveland Open-Cup Flash Point Tester
DSHD-3536 Cleveland Open-Cup Flash Point Tester

A:Brief description:  DSHD-3536 Cleveland Open-Cup Flash Point Tester is designed according the standards GB/T3536-2008 Test Method for Flash Point and Fire Point of Petroleum Products - Cleveland Open Cup Method,ASTM D92,ISO2592.  DSHD-3536 Cleveland Open-Cup Flash Point ...

Dshing Instrument Co.,Ltd

DSHD-267 Open Cup Flash Point Tester
DSHD-267 Open Cup Flash Point Tester

A:Brief description:  DSHD-267 Open Cup Flash Point Tester is designed accordingthe National Standard GB/T267\"Test Methods for Flash Point and Fire Point of Petroleum Products (Open Cup Methods)\" and Industry Standard of Petrochemical SH/T0318\"Technical Requirements for ...

Dshing Instrument Co.,Ltd

DSHD-0633 Liquid Petroleum Asphalt Flash Point Tester
DSHD-0633 Liquid Petroleum Asphalt Flash Point Tester

Productintroduction: 1)DSHD-0633 Liquid Petroleum Asphalt Flash Point Tester is designed anddeveloped as per T0633\"Liquid Petroleum Asphalt Flash Point Test (Tag Open Cup Methods)\" in the Industry Standard JTJ052 Specification and Test Methods of Bitumen and Bituminous ...

Dshing Instrument Co.,Ltd

Gold GD-261A pensky-martensclosed cup flash point tester
Gold GD-261A pensky-martensclosed cup flash point tester

Power supply AC(220±10%)V, 50Hz Temperature measurement Measuring range: Room temperature~350°C Test range of flash point: 41°C~350°C Flash point≤104°C: error ≤2°C Flash point>104°C: error ≤6°C Accuracy: 0.1°C Heating rate Procedure A: (5~6)°C/min Procedure ...

重庆格纳迪设备有限公司