These load break switch 33kv are intended for outdoor applications. They can be mounted either horizontally or vertically, and are suitable for electrical operation and power distribution by power distribution cabinet. These 33kv load break switch are tested by our quality controllers on various parameters before delivering them to our valued customer ends. We manufacture these switches with the help of cutting edge technology, which allows us to deliver a flawless product that is sure to be flawless as well. The 33 kV live parts are not directly touchable and hence guarantee protection from hazards. 
  
 
  33kv Load Break Switch Application 
  The 33kv pole mounted switch is made of a proven rugged, corrosion-resistant material (304L stainless steel plate for warships), ensuring a long service life (30 years) and a range of operations, with the characteristics ideal for on-column equipment. 
  
 
  33kv Load Break SwitchTechnical Parameters 
  Products Type FWX-36 
  Basic Ratings 
  Maximum System Voltage 36kV 
  Rated Continuous Current 630A 
  Rated Frequency 50/60Hz 
  Short Time Withstand Current 16kA/1sec 
  Making and Breaking Capacity 
  Mainly Active Load Current 630A 
  Number of Load-break Operations 400times 
  Short-circuit Making Current (peak) 40kA 
  Number of Making Operations 5 times 
  Cable Charging Current 25A 
  Line Charging Current 1.5A 
  Closed Loop Circuit Current 630A 
  Transformer Magnetizing Current 22A 
  Power Frequency Withstand Current Test 
  Wet Condition-10sec Ph- Ph-Eth, Across Interrupters 70kV 
  DryCondition-1min,Ph- Ph, Phase to Earth 95kV 
  Dry Condition - 1 min Across Interrupter 110kV 
  Impulse Withstand Current Test( 1.2 x 50 µs ) 
  Phase to Phase, Phase to Earth 195kV 
  Across Interrupter 215kV 
  Other Ratings & Specifications 
  Internal Arc Test 20kA /0.1 sec 
  Arc Extinction Medium SF6 Gas 
  Insulation Medium SF6 Gas 
  Creepage Distance (Porcelain) 1055mm 
  Creepage Distance (Silicon) 1550mm 
  Dry arcing distance ≥ 
  IP Level 65 
  Operation Performance 
  Closing/Opening Time <1sec 
  Mechanical Operations (Guaranteed) 10000times 
  Operating Temperature (*Manual Type) -25~+70℃ 
  Gas Pressure 
  Nominal Pressure (MPa, at 20°C) 0.07 
  Bursting Pressure (MPa) 0.4~0.6 
  Minimum Gas Pressure (MPa) 0.05 
  Leakage Rate (cc/ sec) ≤0.5% 
  Voltage sensors 
  CT ABC 10P10 5VA 400:05:00 
  Incoming side and outgoing side of the voltage sensor 6 Voltage sensor(built-in) 
  Phase voltage:(24(36)kV/√3)/(3.25V/√3) 
  Special attention should be paid to the voltage sensor, which must be directly fed by the 33KV load break interrupter switch. 
  No additional adjustment circuit can be added to the controller. The voltage signal of the 33kv load break switch into the test line needs to be tested separately. 
  
 
  Gopower is a professional electric power equipment ltd, we provide auto recloser, load break switch and etc. For more information, please feel free to contact us!