GF102 PORTABLE SINGLE PHASE ENERGY METER TEST BENCH

Product sourcing details

Place Of Origin
China
Minimum Order
1
FOB Price
USD $11,655.00 / Piece
Packaging
1 set each Wooden box
Delivery
7 Days

The GF102 series portable single phase energy meter test bench used to calibrate 1pc or 3pcs single phase energy meter or AC meter at same time. Adopt mature signal synthetic and power amplifier technology, high precision voltage source and current source output from 120A/600V, accuracy 0.02% or 0.05%. Widely used in lab and field, and then as single phase standard source. It is suite for electricity meter manufacturing enterprises, scientific research institutes, metrological service institutions, electricity power utilities etc. This model GF102 portable meter test bench have been used for more than eighty countries in the world. It is stable, reliable and high-precision, welcome to choose it! YOU CAN ALSO LOOK IT IN:https://www.gfuve.com/energy-meter-calibration/portable-single-phase-energy-meter-test-bench.html

FEATURES

  • Test by automatic or manual
  • 3 channel voltage isolation
  • Accuracy class 0.02/0.05/0.1
  • Test 3pcs meter synchronously
  • 7 inch TFT touch color screen
  • Start testing and creep testing
  • 0-120A, 0-600V,40-70Hz, 0-360.000
  • Recorder 1000 sets energy meter data
  • Reference standard and power source integrated
  • Overload, short circuit, open circuit protection

FUNCTIONS

  • Measuring the distortion factor;
  • Multi load point setting output;
  • Testing single phase power meter;
  • Testing meter installations in 1P2W;
  • Testing single phase power factor meter;
  • Many plan auto test for energy meter error;
  • Vector representation of the measuring values;
  • Measuring frequency, phase shift and power factor;
  • Measuring mechanical meter and electric meter error;
  • Energy dosing with built-in current source and voltage source;
  • Power and energy measurements for active, reactive and apparent power;
  • Harmonic spectrum analysis for voltage and current up to the 63nd order;

PARAMETERS

Electrical parameters
Accuracy class0.02%, 0.05%, 0.1%
Power SupplyOne Phase AC 100-265V, frequency 50/60Hz.
AC Voltage Output
Range57.7V, 100V, 220V, 380V; max 600V
Adjustment range(0-120)%RG(1)
Adjustment fineness0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability0.01%/120s
Distortion0.1% (Non-capacitive load)
Output load25VA or 50VA
Measuring accuracy0.02%RG or 0.05%RG
AC Current Output
Range200mA, 1A, 5A, 20A, 100A; max 120A
Adjustment range(0-120)%RG
Adjustment fineness0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability
Distortion≤0.1% (Non-capacitive load)
Output load50VA or 100VA
Accuracy0.02%RG or 0.05%RG
Power Output
Active power output stability
Reactive power output stability
Active power measuring accuracy0.02%RG or 0.05%RG
Reactive power measuring accuracy0.05%RG or 0.1%RG
Phase Output
Output adjustment range0°-359.999°
Output adjustment fineness10, 1, 0.1, 0.01 as optional.
Resolution0.01°
Accuracy0.02° or 0.05°
Power Factor
Adjustment range-1 ~ 0 ~ 1
Resolution0.0001
Measurement accuracy0.0005
Frequency Output
Adjustment range40.000Hz-70.000Hz
Output adjustment fineness5Hz, 1Hz, 0.1Hz, 0.01Hz as optional.
Resolution0.001Hz
Accuracy0.002Hz
Voltage /Current/Harmonic Setting
Harmonic number2-63times
Harmonic content0-40%
Harmonic phase0-359.99
Harmonic setting accuracy(10%±0.1%)RD(2)
Power Energy Measurement Error
Active power energy0.02%RG or 0.05%RG
Reactive power energy0.05%RG or 0.1%RG
Power Pulse Output
Power pulse typeactive pulse, reactive pulse
Active power pulse output5V, 10mA
Power Pulse Input
Energy pulse typesupport active and reactive pulse, the highest frequency power pulse input is 200K.
Standard
StandardIEC 62053-21,22, 23; IEC 60736; IR46; ANSI C12.20-2002;
JJG 597-2005; JJG596-2012; JJG 1085-2013; JJF 68-2019;
DL/T 826-2002; DL/T 1478-2015; DL/T 448-2016
Safety
Isolation protectionIEC 61010-1:2001
Measurement Category300 V CAT III, 600 V CAT II
Degree of protectionIP20
Declaration of conformityCE & CNAS certified
Functions
LCD7 inch touch TFT color LCD
Key26pcs
Communication portRS232 or USB
Register testYes
ProgrammableYes
Meter position1pc or 3pcs
Data storage1000groups
PC control softwareOptional
Mechanical parameters
Dimensions (W×D×H) (mm)455x440x150
Weight (kg)12
Environmental conditions
Ambient temperature-10°C to +40°C
Relative humidity35%-85%
(1)RG means range, the same as below;
(2)RD means the setted harmonic content, harmonic can be a single output,also multiple output.

SELECTION GUIDE

NO.AccuracyVoltage rangeCurrent RangeWeight
10212010.1%0-500V0-120A12KG
102120050.05%0-500V0-120A12KG
102120020.02%0-500V0-120A12KG
1022410.1%0-500V0-24A10.8KG
10224050.05%0-500V0-24A10.8KG
10224020.02%0-500V0-24A10.8KG
1021210.1%0-500V0-12A10KG
10212050.05%0-500V0-12A10KG
10212020.02%0-500V0-12A10KG
102610.1%0-500V0-6A8KG
1026050.05%0-500V0-6A8KG
1026020.02%0-500V0-6A8KG

  • Company: gfuvegroup
  • Contact: Andy Andy

gfuvegroup

Enter between 20 to 3,000 characters. English only. Characters: 0 / 3000
submiting now We do inquire for you, please wait...