A:Brief description:
DSH-261 Pensky-Martens Closed Cup Flash Point Tester is manufactured as per standards GB/T 261-2008 Determination of Flash Point(Pensky-martens Closed Cup) and ASTM D93.
DSH-261 Pensky-Martens Closed Cup Flash Point Tester is suitable to make determination of the closed cup flash point of the petroleum products which flash point over 40℃.
B:Main advantages:
1. This instrument is designed correspond with the requirements of GB/T261-2008.
2. The heating power is continuously and stepless adjustable. The power is shown visually by voltmeter. The temperature control mode is advanced and reasonable.
3. The structure is designed small and exquisite. The stainless-steel table board is beautiful and easy to clean.
4. Operation is easy. Test results are precise. It has been chosen as the instrument to test the closed cup flash point by many metering and detecting units.
C: Main technical specifications and parameters
1.Power supply: AC (220±10%)V, 50Hz.
2.Heating device:The heating power is continuously adjustable from 0 W to 600W.
3.Rate of sample’s heating up:: (1~12)℃/min;Controllable and adjustable.
4.Electric stirring rate: (1)(90~120)turns/min,suitable to test procedure A.
(2)(250±10)turns/min,suitable to test procedure B.
5.Standard oil cup: (1)Inner diameter: 50.7mm~50.8mm.
(2)Depth: 55.7mm~56.0mm.
(3)The scribed line depth of capacity of testing oil: 33.9mm~ 34.3mm.
(4)Capacity of testing oil:about 70ml
6.Igniting device: (1)Igniting source: gas(or other civilian fuels,the same below)
(2)Bore diameter: 0.8mm
7.Thermometer: Mercurial thermometer, correspond with GB/T261-2008
(1)Scale -5℃~110℃, division 0.5℃
(2)Scale 20℃~150℃, division 1℃
(3)Scale 90℃~370℃,division 2℃
8.Ambient temperature:≤ 35℃
9.Relative humidity:≤ 85%
10.Power consumption of overall unit: ≤ 650W
A:Brief description: DSHD-5208 Rapid Closed Cup Flash Point Tester is manufactured as per GB/T 5208-2008 Determination of flash point - Rapid equilibrium closed cup method. DSHD-5208 Rapid Closed Cup Flash Point Tester Conforms tothe requirements of rapid ...
A:Brief description: DSHD-261-1 Pensky-Martens Closed Cup Flash Point Tester is manufactured as per standards GB/T 261-2008 Determination of Flash Point(Pensky-Martens Closed Cup) and ASTM D93. DSHD-261-1 Pensky-Martens Closed Cup Flash Point Tester issuitable to make ...
A:Brief description: DSHD-261A Automatic Pensky-Martens Closed Cup Flash Point Tester is designed according industrial standard SH/T0315 Technical Specifications of Closed Cup Flash Point Tester. The main function ofDSHD-261A Automatic Pensky-Martens Closed Cup Flash ...
A:Brief description: DSHD-261D Fully-automatic Pensky-Martens Closed Cup Flash Point Tester is designed accordingthe standards GB/T261-2008 Test Method for Flash Point of Petroleum Products by the Pensky-Martens Closed Cup Method and ASTM D93. Its function isto ...
A:Brief description: DSHD-3536A Automatic Cleveland Open Cup Flash point tester is designed according the standards GB/T3536-2008 Test Method for Flash Point and Fire Point of Petroleum Products - Cleveland Open Cup Method, ASTM D92 and ISO 2592. DSHD-3536A Automatic ...
A:Brief description: DSHD-3536-1 Cleveland Open-Cup Flash Point Tester is designed according the standards GB/T3536-2008 Test Method for Flash Point and Fire Point of Petroleum Products - Cleveland Open Cup Method,ASTM D92 and ISO2592. DSHD-3536-1 Cleveland Open-Cup Flash ...
A:Brief description: DSHD-3536 Cleveland Open-Cup Flash Point Tester is designed according the standards GB/T3536-2008 Test Method for Flash Point and Fire Point of Petroleum Products - Cleveland Open Cup Method,ASTM D92,ISO2592. DSHD-3536 Cleveland Open-Cup Flash Point ...
A:Brief description: DSHD-267 Open Cup Flash Point Tester is designed accordingthe National Standard GB/T267\"Test Methods for Flash Point and Fire Point of Petroleum Products (Open Cup Methods)\" and Industry Standard of Petrochemical SH/T0318\"Technical Requirements for ...
Power supply AC(220±10%)V, 50Hz Temperature measurement Measuring range: Room temperature~350°C Test range of flash point: 41°C~350°C Flash point≤104°C: error ≤2°C Flash point>104°C: error ≤6°C Accuracy: 0.1°C Heating rate Procedure A: (5~6)°C/min Procedure ...
Ⅰ.Introduction GD-3536D ASTM D92 Fully-Automatic cleveland Open Cup Flash Point Tester is designed and made as per the National Standard of People’s Republic of China GB/T3536 “Test Methods for Flash Point and Fire Point of Petroleum Products (Cleveland Open Cup ...