DC leakage measurement,small DC current Zinc manganese dry battery 6F22 9V, lasting time 30 hours Clamp CT, non-contact measurement Detected wires are in the jaw center position
PLT3180 Auto clampleakage currenttesteris also called the auto leakage current , auto dark current clamp meter, auto charging current tester.It was designed manufacturing for measuring automobile dark current, leakage current.
Functionof leakage current tester
Using the latest CT and digital integration technology, non-contact measurement,No need to disconnect the line
Fast, safe and reliable,small size, high precision, anti-interference ability, automatic shift
It can be used for detecting the current leakage rapidly, such as harness breakage leakage, electrical escape, line grounding and other faults, measuring motor starting current, generator
charging current and so on.
Widely used in vehicle maintenance, automobile factory inspection, auto parts production testing, telecommunications room current detection, power maintenance, weather, oil field
testing.
leak tester Specification | |
Function | DC leakage measurement,small DC current |
Power | Zinc manganese dry battery 6F22 9V, lasting time 30 hours |
Measuring way | Clamp CT, non-contact measurement |
Jaw size | 16mm×18mm |
Measurement range | 0mA~60.0A AC/DC |
Resolution | 1mA AC/DC |
Accuracy | ±2%rdg±5dgt(23℃±5℃,below75%rh) |
Display mode | 4-digit display |
Meter Diamention | 215mm×61mm×32mm |
LCD Diamention | 35mm×21.5mm display diamention 32mm×15mm |
Sampling rate | 2 times/second |
Frequency response | AC 45Hz~400Hz |
Polarity indication | DC current detection automatically identify and display - |
Conductor position | Detected wires are in the jaw center position |
Shift | Automatic switching |
Line voltage | Below AC 600v |
Communication parameters | Baud rate 9600, data bit 8, stop bit 1, parity bit NONE |
Data storage | 99 group, flashing FULL means the memory is full |
Data retention | DH |
Overflow display | OL A |
Automatic shut-down | 5 minutes after the boot, the instrument automaticallyshut down to reduce battery consumption |
Meter weight | 220g |
Working Current | Max 20mA |
Working temperature and humidity | -10℃~50℃;below80%rh |
Limit temperature error | -10℃~0℃and 40℃~50℃ |
Storage temperature and humidity | -10℃~60℃;below 70%rh |
Dielectric strength | AC 3700V/rms |
safety regulations | IEC1010-1、IEC1010-2-032、Pollution level 2、CATⅢ(600V) |
Dc high voltage generator with dc leakage current testing Introduction: ZGF Series 60kV to 300kV DC High Voltage Generator is an important equipment for DC voltage withstand test and leakage current test of HV electrical equipment, cables, surge arresters in electriv industry ...
secondary current injection test device microcomputer relay protection tester Test set INTRODUCTION: The instrument is applied to test the relay unit in relay protection system.At the same time it could be considered as a universal three phase AC/DC voltage source or current ...
Using Magnetic modulation acquisition technology Straight-through current input mode, high isolation ability High sensitive, high performance-price ratio Linear measuring range: 0 - 120% of nominal input Isolation: >3kV DC 1min Overload: 500% of nominal input, 5 seconds. Mean ...
Standardï¼according to IEC61215ãIEC61646ãGB/T 18911and GB/T9535 Purposeï¼evaluate component under the wet work conditionalâs insulation performance ,verification rain, fog,dew , or defrost wet canât enter into the component inner circuit work parts, ...
GDBC-901 Current Transformer Transformation Ratio Tester 1. Product introduction Current Transformer Transformation Ratio Tester is applied to measure the voltage ratio of three or single phase transformer. All the data and test results are shown on a 320*240 LCD screen. All ...
SLQ Series Primary Current Inject Tester Introduction SLQ Seirest Primary Current Inject Tester is a sort of special equipment designed and manufactured for experimentation of electrics of power business as well as industrial and mining enterprises, and which is applicable to ...
Gerneral Introduce GDJB-III Primary and Secondary Current Inject Device Tester is used to adjust and test relaying protection tester of power supply system .It's high precision ,full function ,stable performance ,easy operation and so on . Main Function ♦ DC voltage relay ...
I Introduction This CT PT tester/ current and potential transformer tester is performing excitation, ratio and phase error, polarity, secondary loop burden and coil resistance on current and voltage transformer. The instrument provides fully automatic testing and calibration ...
I.Application GDDZ insulating gloves and boots is application to test leakage current,insulation aging,power frequency of insulating gloves and boots. It can test 3 paris for each time and to read leakage current of each pair in order to find which one is unqualified.There are ...