O2-M2 Oxygen Sensor Description
Alphasense Oxygen sensors use capillary flow control.
Unlike partial pressure oxygen sensors, they have good pressure and temperature dependence, making them the best choice in safety applications.
Standard galavanic sensors use lead for greatest reliability but fixed lifetime.
O2-M2 Oxygen Sensor Specifications
Output: 80 to 120 μA @ 20.9% O2
Response time: < 15 t90 (s) from 20.9% to 0% O2
Zero current: < 2.5μA in N2
Linearity: 0.6% O2 deviation @ 10% O2
Temperature range: -30 to 55 ℃
Pressure range: 80 to 120 kPa
Humidity range: 5 to 95 % rh continuous (0 to 99% rh short term)
Height: 17.4mm (including foam ring)
Weight: < 16g
GH-SW320 SWIR Sensor are two-dimensional image sensors that have a hybrid structure consisting of a CMOS readout circuit (ROIC: readout integrated circuit) and back-illuminated InGaAs photodiodes for short wavelength infrared (SWIR, 900nm-1700nm) and extended wavelength ...
Dongfang Yoyik Dissolved Oxygen Sensor A-87.213.050 for Indonesia Thermal Power Selection of advanced technology, absolutely first-class service quality, YOYIK over the years to the same faith. The main technical backbone are retired senior engineer, senior mechanic. Many of ...
GH-SW640 InGaAs area image sensors are two-dimensional image sensors that have a hybrid structure consisting of a CMOS readout circuit (ROIC: readout integrated circuit) and back-illuminated InGaAs photodiodes for short wavelength infrared (SWIR, 900nm-1700nm) and extended ...
GH-SW320 InGaAs area image sensors are two-dimensional image sensors that have a hybrid structure consisting of a CMOS readout circuit (ROIC: readout integrated circuit) and back-illuminated InGaAs photodiodes for short wavelength infrared (SWIR, 900nm-1700nm) and extended ...
GH-SW1280 InGaAs area image sensors are two-dimensional image sensors. The ingaas sensor has a hybrid structure consisting of a CMOS readout circuit (ROIC: readout integrated circuit) and back-illuminated InGaAs photodiodes for short wavelength infrared (SWIR, 900-1700) and ...
QC102 NDIR infrared carbon dioxide sensor is a common type, small size sensor, using non-dispersive infrared (NDIR) principle to detect the existence of CO2 in the air, with good selectivity, non-oxygen dependent and long life. Built-in temperature compensation; and it has UART ...
GH-SW640 InGaAs area image sensors are two-dimensional image sensors that have a hybrid structure consisting of a CMOS readout circuit (ROIC: readout integrated circuit) and back-illuminated InGaAs photodiodes for short wavelength infrared (SWIR, 900nm-1700nm) and extended ...
GH-SW320 InGaAs area image sensors are two-dimensional image sensors that have a hybrid structure consisting of a CMOS readout circuit (ROIC: readout integrated circuit) and back-illuminated InGaAs photodiodes for short wavelength infrared (SWIR, 900nm-1700nm) and extended ...
GH-SW1280 ingaas sensor are two-dimensional image sensors that have a hybrid structure consisting of a CMOS readout circuit (ROIC: readout integrated circuit) and back-illuminated InGaAs photodiodes for short wavelength infrared (SWIR, 900-1700) and extended wavelength infrared ...
Air quality manufacturer: High Resolution TVOC Detection Modules, Slow Rate of Decay, Gas Sensory Semiconductor Principle, DC 4.8-5.2V, TTL Interface. Specification Parameters Measurement Type: CH2O, C6H6, CO, H2, C2H6O, NH3, Cigarette Smoke, Essence, etc Power Voltage: 4.8-5.2V ...