LVL-500 Series ToughSonic CHEM 35 Chemically Resistant Ultrasonic Level Sensor

Minimum Order
1
Brand Name
Senix
Place Of Origin
United States
Packaging
N/A
Delivery
15 Days

ToughSonic CHEM 35 Level Sensor
Liquids or Solids in Chemically Aggressive Environments

CHEM series sensors and SenixVIEW software put the power of ultrasonics in your hands. You can quickly adjust, optimize, save and clone your applications quickly without calibration!

These sensors are housed in a rugged, chemically inert PVDF sealed housing for long life. They mount above the material surface and measure distance downward without contact. Outputs respond to that measured distance.

Applications include pump control, bulk inventory, batch pro- cessing, water management and high/low level alarms.

Non-Contact Ultrasonic Distance & Level Measurement

Features
Level Measurements
• Long or short measurements
• Unaffected by optical factors like color and transparency
• Computer (PC) software allows remote adjustment
Packaging & Performance
• Durable housing for long life
• Bottom and top thread mounts
• Short & overload protected I/O
• Adjustable filters compensate for tank mixers or turbulence
• Temperature compensation for improved accuracy
• Adjustable sensitivity
Free Functionality
Use adjustable interface features like switch hysteresis and time delays to build complete solutions such as pump controls to maintain level. Save cost by eliminating PLCs, delay circuits and time delay relays!

Specifications

Optimum Range 25 ft. (7.6 m) Max Range 35 feet (10.7 m)
Deadband Typ. < 12 in. (30.5 cm) Adjustment SenixVIEW software
Case Material PVDF Configuration Stored in non-volatile memory
Temperature -40 to 158 ℉ (-40 to 70 ℃) Outputs Five selectable, plus serial data
Humidity 0 to 100% operating Transducer Rugged piezoelectric
Compensation Temperature compensated Protection NEMA-4X, NEMA-6P, IP68
Resolution Digital 0.0135 in. (0.344 mm); Analog 4099 steps (0-10 VDC), 3279 steps (4-20 mA)
Repeatability Nominal 0.2% of range @ constant temp. Affected by target, distance, environment
Update Rate 5 Hz (200 ms), SenixVIEW adjustable; affected by SenixVIEW filter selections
Voltage Output 0-10, 0-5 VDC or PC customized; 10 mA max. (*)
Current Loop #1 Current sourcing 4-20 mA or PC customized, max. loop 450Ω(*)
Current Loop #2 Current sinking 4-20 mA or PC customized, max. loop 450Ω(*)
Sinking Switch 150 mA max. @ 40 VDC max., teachable set point & polarity, fault indication
Sourcing Switch 150 mA max. @ input voltage, teachable set point & polarity, fault indication
RS-232, RS-485 Modbus protocol, 9600-115200 baud (selectable), 8 data bits, 1 stop, no parity
Target Requirements
Target Detects flat or irregular surfaces. Target surface must reflect sound back to sensor.
Max. Distance Affected by size, shape, orientation of target (sound level reflected back to sensor), environment

Restrict use to Optimum Range when using over a wide range of environmental conditions

Granular Solids De-rate max range by 50%; range affected by material density and orientation
Orientation Orient sensor beam perpendicular to target surface for best performance
Optical Unaffected by target color, light level, transparency or other optical characteristics

Connections
Cable Connection Wire Description
Power Brown 10-30 VDC @ 50 mA maximum; Typical: 45 mA @ 24 VDC (**)
Ground Blue Power and interface common
Voltage Output * Violet 0-10 VDC, 0-5 VDC or custom end values between 0 and 10 VDC
Current Loop Output * Green 4-20 mA sourcing (adjustable end values between 4 and 20 mA)
Current Loop Output * Orange 4-20 mA sinking (adjustable end values between 4 and 20 mA)
Switch #1 Output Black Sinking ("NPN") or Sourcing ("PNP"), user selected
Switch #2 Output White Sinking ("NPN") or Sourcing ("PNP"), user selected
RS-232 out / RS-485- Gray Serial data connection (depends on model - see model selection)
RS-232 in / RS-485+ Yellow Serial data connection (depends on model - see model selection)
(*) Analog outputs share common distance endpoints. Both 4-20 mA outputs share the same adjustable max / min values. The max. loop resistance is derated below 15 VDC input voltage.
(**) At default update rate. Output currents not included. Sensitivity reduced below 15 VDC input voltage

Part Numbers
Model Number Description
LVL-500-232 Serial RS-232 interface (PC COM port compatible)
LVL-500-485 Serial RS-485 interface (allows addressable multi-sensor networks)
Senix also offers interconnection, communication, mounting, and display components
  • Country: China (Mainland)
  • Business Type: Distributor/Wholesaler
  • Market:Europe, America, etc
  • Founded Year:2014
  • Address:sales@isweek.com
  • Contact:zy
more images of LVL-500 Series ToughSonic CHEM 35 Chemically Resistant Ultrasonic Level Sensor
*Your name:
*Your Email:
*To:Week Technology LTD
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters : 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

submiting now We do inquire for you , please wait ...

LVL-100 Series ToughSonic CHEM 10 Chemically Resistant Ultrasonic Level Sensor
LVL-100 Series ToughSonic CHEM 10 Chemically Resistant Ultrasonic Level Sensor

ToughSonic CHEM 10 Level Sensor Liquids or Solids in Chemically Aggressive Environments CHEM series sensors and SenixVIEW software put the power of ultrasonics in your hands. You can quickly adjust, optimize, save and clone your applications quickly without calibration! These ...

Week Technology LTD