Cells Per Unit | 6 |
Voltage Per Unit | 12 |
Capacity | 100ah@20hrs-rate to 1.75v per cell @25℃/77°F |
Approx Weight | 29.0kg (Tolerance±1.5% ) |
Max.Discharge Current | 1000A (5sec) |
Internal Resistance | Approx 5.6mΩ |
Operation Temp.Range | Discharge: -15-50℃ (5-122°F) |
Charge: 0-40℃ (32-104°F) |
Storage: -15-40℃ (5-104°F) |
Nominal Operating Temp.Range | 25±3℃ (77±5°F) |
Float Charging Voltage | 13.5V-13.8V (25℃/77°F) Coefficient:20mv/℃ (No limit on Initial Charging Current) |
Recommended Maximum Charging Current | 35A |
Equalization and Cycle Service | 14.4V-14.8V (25℃/77°F) Coefficient:30mv/℃ (Initial charging current less than 16.5A) |
Self Discharge | RITAR Valve Regulated Lead Acid (VRLA) batteries can be stored for more than 6 months at 25℃. Self-discharge ratio less than 3% per month at 25℃. Please charge batteries before using. |
Terminal | T5 or F7 |
Container material | ABS UL94-HB,UL94-V0 Optional |