Windbreak panel wall Design Windbreak wall is composed of three parts reinforced concrete foundation, steel frame and ground windbreak panel. According to the local meteorological data and the surrounding residential areas, industrial and working protection requirements, while en
AWD Windbreak Panels Company [2014-09-16 20:15:34 ]
ZP6110 UV Exposure Machine I. Introduction 1 . 3KW iodine gallium UV light tube 2 .It is easy for fixing PCB plate 3 . Work zone 1000MMx1000mm 4 . Digital timer 5 . Counter range 0-999 second auto reset 6 . It can exposure again, separate select up or down exposure. 7 .With vacuu
Jinan Should Shine Import And Export Co., Ltd. [2014-09-16 02:46:35 ]
ZP6109 Automatically Circuit Board Polishing Machine I. Introduction 1.Usage copper-clad plate, aluminum plate, stainless plate, PVC material metal, non metal surface polished treatment , it is usually used in making double sides hole, copper plating and galvanize, ink printing p
Jinan Should Shine Import And Export Co., Ltd. [2014-09-16 02:45:37 ]
ZM2148 Heat Transfer Experiment Apparatus I Technical parameters 1.Tube heat exchanger inner tube ф 22X1.5mm, external tube ф 52X1.5mm, heat exchange length 1.0m. 2. vapor generator stainless material, heating power 2KW, operate voltage 220V. 3. Pump centrifugal middle pressure
Jinan Should Shine Import And Export Co., Ltd. [2014-09-16 02:21:54 ]
ZM2143 Orifice Discharge Apparatus I Technical parameters Experiment purpose 1. To understand Venturi meter principle and experiment equipment features. 2. Through test differential pressure and fluid relationship curve, to determine Venturi. meter fluid coefficient μ value. 3.T
Jinan Should Shine Import And Export Co., Ltd. [2014-09-16 02:17:59 ]
ZM2142 Pipes Fluid Friction Venturimeter Hydraulic Bench I Technical parameters 1.Water pump power 90W, hydraulic head 8m, rated flow 10L/min. 2. Experiment tank is made of organic glass, with stable overflow port. 3. Storage tank is made of PVC plate, the volume is about 60L. 4
Jinan Should Shine Import And Export Co., Ltd. [2014-09-16 02:17:01 ]
ZM2141 Pump in series and parallel Apparatus I Technical parameters 1.Function environment temperature 0-40 degree, relative humidity ≤90%RH, power supply 220V/50Hz, it can operate continuously. 2. centrifugal pump use 20SG2.5-15G type tube centrifugal pump, rated power 0.37KW,
Jinan Should Shine Import And Export Co., Ltd. [2014-09-16 02:16:06 ]
ZM2139 Measures Fluid Friction Apparatus I Technical parameters 1.Rough tube section stainless tube, tube diameter 25mm. Tube length 1.6m,internal with stainless screw ot industrial galvanized tube. 2.Smooth tube section stainless smooth tube, tube diameter 25mm. Tube length 1.5m
Jinan Should Shine Import And Export Co., Ltd. [2014-09-16 02:14:16 ]
ZM2135 Defeats Local Load Apparatus I Technical parameters 1.Experiment water tank is made of Organic glass, with steady pressure overflow port . 2.Water pump work power 90W. Top lift 8m, rated fluid 10L/min. 3. Bend pipe resistance two point test pressure distance is 200mm. 4.
Jinan Should Shine Import And Export Co., Ltd. [2014-09-16 02:12:29 ]
ZM2134 Methods Flowmeter Apparatus I Technical parameters 1.Water pump maximum fluid 30L/min. Top lift 16m. Power 370W. Work voltage 220V. Rotary speed 2850r/min 2.Hole plate diameter dO=8mm, stainless material. 3. Venturi tube throat diameter dV=8mm, stainless material. 4.Meteri
Jinan Should Shine Import And Export Co., Ltd. [2014-09-16 02:11:28 ]
ZM2133 Demonstration Osborne Reynolds Apparatus I Technical parameters 1.Organic glass sink >30L. 2.Organic glass observation tube Φ20mm. 3.Metering water tank volume >8L. 4.Indicate liquid is red ink or other colorful ink liquid. 5.Structure is stainless, structure is light and
Jinan Should Shine Import And Export Co., Ltd. [2014-09-16 02:10:34 ]
ZM2132 Flume s Apparatus I Technical parameters 1.Function environment temperature 0-40 degree, relative humidity ≤90%RH, power 220V/50Hz, single phase, can be adjust continuously. 2.Use low noise no corroding environmental small water pump, top lift 35m,maximum fluid 2.5m3/h,
Jinan Should Shine Import And Export Co., Ltd. [2014-09-16 02:05:29 ]
ZM2130 Impact Jet Apparatus I Technical parameters 1.Function environment temperature 0-400C,relative humidity≤90%RH,Power supply 220V/50Hz,it can opearte continuously. 2.Storage tank volume 20L, PVC plate welding plate. 3. Flowmeter rotameter flowmeter, fluid range 60-600L/H.
Jinan Should Shine Import And Export Co., Ltd. [2014-09-16 02:03:26 ]
ZM2129 Pressure Balance Apparatus I Technical parameters 1. Operating environment temperature 0-40 degree, relative humidity ≤90%RH, power supply 220 v / 50 Hz,be able to continuous operation. 2. Piezometric tube ф 8 x 600 mm, 6 eas. 3. Experimental container ф 200 x 300 mm,
Jinan Should Shine Import And Export Co., Ltd. [2014-09-16 02:02:25 ]
ZM2128 Laminar And Turbulent Flow Apparatus I Technical parameters I Equipment configuration The experiment device is mainly by the water tank experiment tube kit PVC pipe valves and stainless steel platform, etc The experimental pipe inner diameter 16 mm, length 1000 mm, transpa
Jinan Should Shine Import And Export Co., Ltd. [2014-09-16 02:01:26 ]
ZM2127 Bernoulli Experiment Equipment Hydraulic Bench I. Technical specifications 1, Be familiar with the concept of fluid flow in a variety of energy and pressure head and reciprocal transformation relations, deepen the understanding of the Bernoulli equation. 2, Observe the ene
Jinan Should Shine Import And Export Co., Ltd. [2014-09-16 02:00:22 ]
ZM2126 Reynolds Experiment Equipment Hydraulic Bench I. Technical specifications 1, Observation of fluid in pipe flow of two different types. 2, Observe the viscous flow state in pipeline fluid velocity distribution state. 3, Determination of flow patterns and the relationship be
Jinan Should Shine Import And Export Co., Ltd. [2014-09-16 01:57:07 ]
ZM2125 Impact Of Jet Apparatus CW Hydraulic Bench I. Technical specifications Specifications 2000mm×300mm×1800mm Power 220V,370W Technical file Can be used as orifice, nozzle discharge tube and flat jet momentum test. Main configuration organic glass tank experiment, the contro
Jinan Should Shine Import And Export Co., Ltd. [2014-09-16 01:52:51 ]
ZM2124 Piping Losses System I. Technical specifications Dimension 2000mm×600mm×1800mm Power 220V, 200W Valve as local resistance in the pipe (or with sudden enlargement, a sudden shrinkage) as object, the manometer was used to measure water flow in the pipe valve before and aft
Jinan Should Shine Import And Export Co., Ltd. [2014-09-16 01:50:46 ]
ZM2123 Flow Meter Trainer I. Experiment 1. Be familiar with the structure of the orifice flowmeter and its application. 2. Master flowmeter flow correction methods. 3. Through the determination of the coefficient of flow metering, know the rule of variation of flow coefficient. I