Items Parameters Control box size 470mm × 550mm × 700mm Measuring probe operating temperature -60 ℃~ -40 ℃ Digital thermometer measuring range -65 ℃ ~ +50 ℃(Note adjustable measuring range) Temperature resolution 1 ℃ Power supply AC220V 50Hz
Shanghai Qianshi Precision Electromechanical Techn [2025-02-11 11:14:54 ]
Technical indicators 1. Pressure range and measurement accuracy 0 ~ 0.04MPa (4mH2O) (31.4kg) accuracy + 1kPa. 2. Sample size 75mm * 75mm, under pressure area 28.26 square centimeters. 3. Power supply AC220V, 50Hz, 100W.
Shanghai Qianshi Precision Electromechanical Techn [2025-02-11 11:10:24 ]
Technical parameters Environment Working temperature 5 ~ 40 ℃ Relative humidity 45 ~ 80%. Power supply voltage 220V plus or minus 22V. Power grid frequency 50HZ + + 1HZ. Device type type B. Display mode Using 320 x 240 single color LCD display, all Chinese Windows display. The
Shanghai Qianshi Precision Electromechanical Techn [2025-02-11 11:09:16 ]
Technical parameters Environment Working temperature 5 ~ 40 ℃ Relative humidity (45 ~ 80) %. Power supply voltage 220V plus or minus 22V. Power grid frequency 50HZ + + 1HZ. 2 display mode Using 320 x 240 single color LCD display, all Chinese Windows display. The keyboard is us
Shanghai Qianshi Precision Electromechanical Techn [2025-02-11 10:59:03 ]
1. Combustion laboratory size 3000mm * 3000mm * 2800mm; 2. Outline dimensions of the smoke pipe in the combustion chamber 5200mm * 3000mm * 1800mm; 3. Control box outline dimension 800mm * 1200mm * 1500mm; 4. Smoke extraction speed 0.50m3/s ~ 0.65m3 /s; 5. Temperature measurement
Shanghai Qianshi Precision Electromechanical Techn [2025-02-10 13:12:34 ]
Measuring range 0-200mN / m Resolution 0.01mN / m Platinum ring R9.55 Platinum wire r0.3 With peak hold function The test tray can be raised and lowered automatically Control mode PLC (programmable controller) Input method 5 inch Delta color touch screen Power supply 220V 50HZ Di
Shanghai Qianshi Precision Electromechanical Techn [2025-02-10 13:11:33 ]
Technical indicators ◎ Stirring paddle and rotating basket specifications in accordance with the Pharmacopoeia regulations ◎ Stirring paddle swinging amplitude ≤0.5mm The swinging amplitude of rotary basket ≤1.0mm. ◎ The deviation of the rotating rod from the axis of th
Shanghai Qianshi Precision Electromechanical Techn [2025-02-10 11:40:37 ]
Optical system laser photoresist method Light source 5mW semiconductor laser Detection range 1~400um Detection channels customized 128 channels, particle size can be set arbitrarily between 2um~100um, accuracy of 0.01um Injector 1mL, 5mL, 10mL, 25mL; standard for 10mL Sampling vo
Shanghai Qianshi Precision Electromechanical Techn [2025-02-10 11:37:17 ]
Mobile design, built-in battery power supply, flexible and convenient movement, safe and reliable work. Dissolving cup, paddle lever in-situ cleaning, to avoid disassembly cleaning, dissolving cup easy to break, dissolving cup need to re-align, paddle lever height re-adjustment.
Shanghai Qianshi Precision Electromechanical Techn [2025-02-10 11:29:08 ]
Speed 25r/min, 30r/min, 40r/min, 50r/min, 60r/min, 80r/min, 100r/min can be set arbitrarily. Counting range 0~9999 r Grinding cylinder inner size Φ36x300mm; Φ50x300mm two each Power supply AC 220v±10% 50HZ
Shanghai Qianshi Precision Electromechanical Techn [2025-02-10 11:23:56 ]
1.Sample holder inner diameter of 118 mm stainless steel ring, inside diameter of 0.70 mm and a mesh diameter is 2.10mm into the stainless steel mesh .Sample installation height can be adjusted 2.Sample size 70 x 70 (mm), the thickness is not more than 13mm 3.Residue container in
Shanghai Qianshi Precision Electromechanical Techn [2025-01-10 10:12:45 ]
1, head mold automatic movement line with the speed of (60 ± 5) mm / s 2, the height of the flame can be adjusted to 40 ± 4mm 3, with a flame temperature measurement detection thermocouple 4, the flame from the top of the burner height is(20 ± 2) mm, the temperature is (800 ±
Shanghai Qianshi Precision Electromechanical Techn [2025-01-09 15:06:46 ]
Air source Suction pump Air flow 8L/min Sealing method Mechanical face seal Diameter for circular sample holder Ф25mm Differential pressure transducer 0-500Pa Display Digital display Power supply 220 AC 50Hz Dimension 550mm×400mm×700mm 21.65inch×15.75inch×23.62inch Net weigh
Shanghai Qianshi Precision Electromechanical Techn [2025-01-09 14:54:17 ]
Items Parameters Operation mode Full color touch screen control Language Chinese– English interface Air source Suction type Air flow rate 5-100min/L Sample plate 190mm round plate Sealing method O-ring sealing Air ventilate aperture of sample 74mm/25mm Differential pressure sen
Shanghai Qianshi Precision Electromechanical Techn [2025-01-09 14:40:43 ]
Items Parameters Dimension 1200mm X 600mmx 1200mm Timer accuracy :0.1s Power supply :220v,50/60Hz
Shanghai Qianshi Precision Electromechanical Techn [2025-01-09 14:28:54 ]
Item Mask Particle Filtering Efficiency Tester Filtration efficiency test range 0 ~ 99.999% Resolution 0.001% Test flow range 10~100 L/min Standard Test Area 100 cm 2 (Can customize) Resistance test range 0 - 1000Pa Particle size ranges are detected 0.3,0.5,1.0,3.0,5.0,10.0 um Du
Shanghai Qianshi Precision Electromechanical Techn [2025-01-09 14:27:36 ]
Operation Model Digital or PLC (Option) Gantry center distance 45mm (rotating frame center to test the bottom of the cup distance) Rotation speed 40±2r/min Test cup size 550ml or 1200ml ( There got 4 cups , 8 cups type) Time control range 0~999min≤±1s Temperature control rang
Shanghai Qianshi Precision Electromechanical Techn [2025-01-09 14:24:33 ]
Flowmeter range 0 ~ 100L/min;Accuracy 3% Digital differential pressure meter range 0 ~ 1000Pa Accuracy 1 Pa Pumping capacity of air pump ≥100L/min Printer Micro thermal printing Language English-Chinese Switchable Weight Approx 50kg Power Supply AC220V 50Hz
Shanghai Qianshi Precision Electromechanical Techn [2025-01-09 14:19:11 ]
The Vertical Flammability Chamber, designed for American Standards, measures the vertical flame spread for children's sleepwear, fabrics, other textile materials or resilient filling materials used in upholstered furniture. Application The vertical burning of textiles is suitable
Standard International Group (HK) Limited [2025-01-08 15:17:46 ]
Application Air Permeability Tester, widely used to test the resistance of fabrics (woven, knitted and non-woven textile materials, medical masks) to the passage of air (air flow), the test textile is firmly clamped by a specified rig of selected test head/area to resist the cons
Standard International Group (HK) Limited [2025-01-08 15:02:08 ]