alpha:s* - Manufacturers, Suppliers & Exporters

Total 628052 products found
Brava Sport System Breast Enlargement

Delivery Time 3-4 Days Package Original Box Minimum Order Quantity 5 Piece/Pieces Payment Terms D/P,T/T Port Soekarno Hatta Airport Brava Sport System Breast Enlargement DETAILS - The Brava Breast Enhancement and Shaping System, a healthier way to get the shape you've always want

PT.ANDALAS JAYA SHOP   

knap sack insecticide pump

Theory Vacuum Pump Place of Origin China (Mainland) Theory Vacuum Pump Place of Origin China (Mainland) insecticide pump - knap sack knap sack /insecticide pump with plastic basket

ARTI IC VE DIS TIC. LTD.   

Special Application Pumps

Fuel Other Standard or Nonstandard Nonstandard Power Electric Usage Water Structure Multistage Pump Theory Centrifugal Pump Brand Name PROCON, CAT, Dickow Place of Origin Ukraine Pressure High Pressure Fuel Other Standard or Nonstandard Nonstandard Power Electric Usage Water Stru

Kiron Hydraulics   

Pump set

Application Submersible Application Submersible Submersible pumps are used for various pumping applications, because of their inherent advantages. Submersible pumps are used for various pumping applications, because of their inherent advantages. The coupled unit consisting of the

Protecto Engineering Pvt. Ltd.   

Diaphragm pumps, Flojet Pump, shurflo pump ,DC pumps 12V / 24V DC PUMPS, pressure pumps, washing pumps

Delivery Time 15 Days after receive payment Package Carton Supply Ability 200 Piece/Pieces per Week Minimum Order Quantity 5 Piece/Pieces Payment Terms T/T Port FUZHOU Pressure Low Pressure Standard or Nonstandard Standard Power Electric Usage Water Structure Diaphragm Pump Model

SUBMERSIBLE EFFLUENT PUMPS

Application Sewage Application Sewage For Handling water containing Soft Solids like Effluent, Sewage, Kitchen WasteModelEV 400Lit / mEV 500Lit / mEV 650Lit / For Handling water containing Soft Solids like Effluent, Sewage, Kitchen WasteModelEV 400Lit / mEV 500Lit / mEV 650Lit /

HARISON PUMPS   

Collet Blocks from 1C to 35J sizes

More models to choose from & Use vertically or horizontally on fixture plates, tombstones or rotary trunnions Pneumatic or hy More models to choose from & Use vertically or horizontally on fixture plates, tombstones or rotary trunnions Pneumatic or hydraulic configurations Aircra

Hardinge   

Gangothri Submersible Pumps

Application Submersible Application Submersible and Motors are the products of the expertise gained from over four decades of experience, endurance and workmanship Gangothrip and Motors are the products of the expertise gained from over four decades of experience, endurance and w

Gangothri Submersible Pumps   

Horizontal Split Casing Pump

Type DSManufacturing Range Size 50mm to 400 mmCapacity Up to 2000 m3/hrsTotal Head Up to 80 metersOperating Temp 10 Type DSManufacturing Range Size 50mm to 400 mmCapacity Up to 2000 m3/hrsTotal Head Up to 80 metersOperating Temp 100C to 900CDesign Features Easy dismantlin

BHARTiYA iNDUSTRiES   

Submersible Clear Water Pumps Sinko bloc SH Series

Application Submersible Application Submersible TECHNICAL SPECIFICATIONSSALIENT FEATURESSinco BlocHeadUp to 150 MTRS CapacityUp to 7000 LPM H.P.0.5 H P.- 75 H PLubrica TECHNICAL SPECIFICATIONSSALIENT FEATURESSinco BlocHeadUp to 150 MTRS CapacityUp to 7000 LPM H.P.0.5 H P.- 75 H P

DARLING PUMPS   

V SERIES PUMPS

V Series Diaphragm PumpsVane pumpsdesign (Patent Pending)Differntial pressures to 50 psi (3.5 bar)Viscositiesfrom 0.3 cps to V Series Diaphragm PumpsVane pumpsdesign (Patent Pending)Differntial pressures to 50 psi (3.5 bar)Viscositiesfrom 0.3 cps to 100 cpsFlows to 1.5 gpm (5.6 l

Florida international : indian Pumps   

Self Priming Centrifugal Pump

Direct or belt drive from motor or engine Direct or belt drive from motor or engine

AN HSIN ENTERPRISE CO.,LTD   

Submersible deep well pumps for over 4 well diameter

Application Fire Application Fire Description Enclose impellers- combined with PU and stainless steel which improves pump efficiency and durabilityPrecise impe Description Enclose impellers- combined with PU and stainless steel which improves pump efficiency and durabilityPrecise

San Da Hsing Mechanical and Electrical Product   

TWIN PRESSES (RM100 SE2)

SpecificationUnitRM 100 SE21. Clamping ForceTon1002. Platen Sizemm455x4553. Cylinder Bore Diamm2504. Stroke / Day Li SpecificationUnitRM 100 SE21. Clamping ForceTon1002. Platen Sizemm455x4553. Cylinder Bore Diamm2504. Stroke / Day Light Gapmm2505. No. of Day LightsNo Single6. Pum

RUBBER MACHINERY   

pump sets

ModelH P.K W.StageDel Size MMDischarge in LPMRHD-102.001.4975095115145160185I SI3028251816RHD-10850393 ModelH P.K W.StageDel Size MMDischarge in LPMRHD-102.001.4975095115145160185I SI3028251816RHD-108503935282519RHD-109504340362723RHD-1011505348393327RHD-1012505046423227RHD-10125

Shri Sujal Purifiers family   

EH-F Series Dosing Pumps

Application Metering Application Metering EH-F Series Dosing Pumps

iwakipumps   

stainless pump casting

Place of Origin Taiwan Place of Origin Taiwan tsi foundry is a professional stainless casting pump manufactuer in Taiwan. Just contact us, we believe our quality and pricing will let you feel satisfied. We use quality grades of stainless steel our range of industrial stainless st

TSI Foundry Corp.   

MS Slurry Pump

Brand Name Kingda Place of Origin China (Mainland) Brand Name Kingda Place of Origin China (Mainland) We Xinda Slurry Pump Co. Ltd supply high quality of siurry pump . We Xinda Slurry Pump Co. Ltd supply high quality of siurry pump. We supply slurry pump and it's accessories, suc

Xinda Slurry Pump Co., Ltd.   

Centrifugal Single Stage pump

Specifications Max. discharge capacity 4.0m3/min Max. head 55m Main materials ETFE/PFA Visit for more details (link will open new window Specifications Max. discharge capacity 4.0m3/min Max. head 55m Main materials ETFE/PFA Liquid temp. range 0 to +100

Pumptechnique Ltd.   

Submersible Solar Pumps

Application Submersible Application Submersible Adopting the proposed dynamic VI maximum power point tracking (MPPT) control method; Fast response and stable operation The system should be optimized according to the requirements of head, capacity, and local conditions of sunlight

SolarVision International