Coil Structure EI 54-EI 84 Phase Single Brand Name LGM EUTRONIC Place of Origin Romania Coil Structure EI 54-EI 84 Phase Single Brand Name LGM EUTRONIC Place of Origin Romania EI Encapsulated Transformers for DIN Rail Mounting according to IEC/EN61558 - Powers 10 VA - 100 VA Spec
We supply quality ignition transformers in bulk to clients in the domestic and international markets. Technical data Ignition system MKZ 100 (Part No. 0.096 600 017) Operating voltage 230 V (-15 % + 10 %) 50/60 Hz Primary Currrent 0.22 A Output Connection 50 VA Primary 2 x flat p
transformers are produced in the range between 10 KVA and 10,000 KVA, with rated voltage up to 36 KV, single phase or three phase, 50 or 60 Hz. dry type or oil immersed hermetically sealed or conservator type. ELECTRICAL CHARACTERISTIC at 75oC, 50 Hz, 3 Phase, 400 VoltSPLN Standa
100% VACCUUM IMPREGNATED TRANSFORMERSRATINGS SPECIFICATIONS 100% VACCUUM IMPREGNATED TRANSFORMERSRATINGS Available in any voltage/amp. combination as required by the user or manufacturer. For use in Inverters, Stablizers, UPSs, TVs, and other electrical & electronic gadgets
We manufacture Power Transformers up to and including 100 MVA/220 We manufacture Power Transformers up to and including 100 MVA/220, KV class. The factory is equipped with latest machineries and testing equipments.
Delivery Time NORMALLY FOUR TO SIX WEEKS Package EXTRA- AS DESIRED BY CUSTOMER Supply Ability 100 Piece/Pieces per Month Minimum Order Quantity 1 Piece/Pieces Payment Terms T/T Port MUMBAI Fob Price US$4666.00MUMBAI GREY OR BLUE OR AS DESIRE BY CUSTOMER Coil Number Other Coil Str
Welding Transformer Name characteristic Value characteristic 1. Mains voltage, V 2E380 2. Mains frequency, Hz> 50 3. Duty cycle, %, at maximal welding current 100 4. No-load voltage, V, no more 70 5. Range of welding current control, 120-500 6. Rated operating voltage, V 40 7. Ra
Amorphous Oil Type Pole Mounted Distribution Transformer Capacity(kVA) No-load Current(%) Voltage Regulation(%) No-load Losses(W) Efficiency(%) Dimensions(mm) Total Weight(kg) W D H 10 1.2 2.0 12 97.9 480 550 1,020 125 20 1.2 1.7 19 98.2 530 600 1,060 180 30 1.0 1.5 25 98.4 560 6
Ballast To use with fluorescent lamp 4-6-8-15-20W EI-28,35,41,48 0.1~14 1~4 With end bell/without end bell "Optional" EI-54,57,60,66,76,86,114 5~200 1~4 1.With end bell 2.With thermal fuse * Ballast * Ballast To use with fluorescent lamp 4-6-8-15-20W * Line Matching Transformer
25KVA TO 2.5 MVA KVARatings No Load Loss (In Watts) Load LossIn Watts LengthMM BreadthMM HeightMM Total Wt Kg. HT LineCurrent (A) LTCurrent (A) 63 180 1235 1200 1100 1360 460 3.30 84.004 100 260 1760 1300 1150 1480 650 5.25 133.34 160 425 3000 1400 1300 1550 830 8.39 213.35 200 5
Each website is unique in its own way and hence our search engine optimization Each website is unique in its own way and hence our search engine optimization (SEO) plans differs from website to website. However we are providing a comparison chart of our five major SEO services to
Simple and robust design with dependable DESIGN FEATURES " Simple and robust design with dependable performance." High metal recovery." Excellent dynamic arc characteristics." Superb efficiency using high conductivity copper and low 'coarsive force transactor." Infinite current
Delivery Time 6 WEEKS Package WOODEN CRATES, WOODEN PALLETS Supply Ability 100 Set/Sets per Day Minimum Order Quantity 12 Set/Sets Payment Terms L/C,T/T Port CHENNAI Fob Price US$1000.00-5000.00CHENNAI SWAN NECK & HEADER TYPE ALL COLOURS SPECIALISTS IN GALVONIZING DIFFERENT SIZES
PME Transformers (India) Ltd. has been manufacturing dry type transformers for the last one decade VACUUM PRESSURE RESIN IMPREGNATED DRY TYPE TRANSFORMERS ? PME Transformers (India) Ltd. has been manufacturing dry type transformers for the last one decade, spread over F, H & C cl
In this type of transformer primary and secondary windings are wounded separately with electrostatic shield in between. This shield is connected to earth. The isolation transformer helps in rerouting unwanted voltages to sink in earth, it protects sophisticated electronic & elect
Transformers & O. L. T. C Repairs Lubricating Oil Filtration EXPERTS IN -Transformers & O. L. T. C Repairs Lubricating Oil Filtration Maintenance of H. T. TransformersRepairs of Power Transformers O C.B/ A. C. B. & Cable work etc. EHV Substation Transformer, Ultra High Vacuum Tr
Minimum Order Quantity 1 Set/Sets Payment Terms L/C,T/T Coil Number Autotransformer Phase Three Usage Power Model Number 100 kVA 3Ph 50Hz 22000-400/230V Brand Name OEM possible Place of Origin Thailand Coil Number Autotransformer Phase Three Usage Power Model Number 100 kVA 3Ph 5
DistributionTransformer II. Dry Type Transformer (VPI Vacuum Pressure Impregnated) DistributionTransformer 100 KVA to 2500 KVA up to 22 class
Low Voltage Capsulated Current Transformer - LV-CTs Low Voltage Capsulated Current Transformer - LV-CTs Sari-SEG Low Voltage Capsulated Current Transformer Technical Data Primary Voltage 0,72 kV / 3 kV Frequency 50 60 Hz Color White Standard DIN 42600 / IEC 185 Encased In