Searching *:* , total 2252983 products,queries done in 253 ms

KL-303 Digital pH/ORP Controller

KL-303 Digital pH/ORP Controller Model KL-303 Measuring range PH 0.00~14.00PH ORP 0~±1999mV Accuracy PH ±0.1%+2 digits ORP ±5 mV Resolution PH 0.01PH ORP 1mV Set Range PH 3.50~10.50PH ORP 0~1000mV Environment Temperature 0~50℃ Humidity<95℅ Power Supply 220V±10℅ 50Hz±

Kelilong Electron Co.Ltd      [2015-04-27 09:36:45 ]

KL-201 Digital pH Controller

KL-201 Digital pH Controller Model KL-201 Measuring range 0.00~14.00PH Accuracy ±(0.1%+2 digits) after calibration Resolution 0.01PH Set Range 3.50~10.50PH Environment Temperature 0~50℃ Humidity<95℅ Power Supply 220V±10℅ 50Hz±2℅ Dimensions 150mm×85mm×40mm Weight 58

Kelilong Electron Co.Ltd      [2015-04-27 09:30:24 ]

KL-601 Digital pH/Temperature Controller

KL-601 Digital pH/Temperature Controller Model KL-601 Measuring range PH 0.00~14.00PH Temperature 0~100℃ Accuracy PH ±0.1%+2 digits Temperature ±0.4℃ Resolution PH 0.01PH Temperature 0.1℃ Set Range PH 3.50~10.50PH Display 4-digital LCD Environment Temperature 0~50℃

Kelilong Electron Co.Ltd      [2015-04-27 09:29:31 ]

KL-803 Digital pH/ORP Controller

KL-803 Digital pH/ORP Controller Model KL-803 Measuring range PH 0.00~14.00PH ORP -1999~1999mV Accuracy PH ±0.1%+0.02PH ORP ±5 mV Resolution PH 0.01PH ORP 1mV Set Range PH 3.50~10.50PH ORP -500~500mV Environment Temperature 0~50℃ Humidity<95℅ Display double 4 LED display

Kelilong Electron Co.Ltd      [2015-04-27 09:16:26 ]

VLF Series Very Low Frequency Generator Insulation Test set

1 Application Very Low Frequency Generator Insulation Test set is applied in power cable and generator insulation test in power system. 2 Technical Index 1 Max voltage output refer to table 1 2 Output frequency 0.1Hz, 0.05Hz, 0.02Hz 3 Measurement error < 3%RDG+0.3%FS 4 Positive a

重庆格纳迪机电设备有限公司      [2015-04-26 21:10:17 ]

GDYJ-502 Insulating transformer oil dielectric strength tester

Product name Insulating oil tester Model GDYJ-502 1 Breakdown test of user-defined 2 Proof test 3 IEC60156/IS6792/BS5874 test 4 ASTM D1816 standard test ASTM D877 standard test 5 5 minutes standard test 6 Manual test 7 Calibration interface for customers, result print 8 Uploading

重庆格纳迪机电设备有限公司      [2015-04-26 21:07:49 ]

GDYJ-502 insulating oil breakdown tester

Product name Insulating oil tester Model GDYJ-502 1 Breakdown test of user-defined 2 Proof test 3 IEC60156/IS6792/BS5874 test 4 ASTM D1816 standard test ASTM D877 standard test 5 5 minutes standard test 6 Manual test 7 Calibration interface for customers, result print 8 Uploading

重庆格纳迪机电设备有限公司      [2015-04-26 21:06:28 ]

GDZC Winding Resistance Tester

Application GDZC Series winding resistance tester are applied to measure the DC resistance of inductance circuit such as power transformer coil, current transformer coil and so on. Also the tester could be applied to measure the cable resistance in 4-wire mode. Functions 1 Windin

重庆格纳迪机电设备有限公司      [2015-04-26 21:04:58 ]

GDBC-901 turns ratio tester of transformer

It is to test voltage ratio, vector, polarity, ratio error of current transformer and voltage transformer. 1 GD BC-901 turns ratio test of transformer Function s 1 The voltage ratio measurement for three or singe phase transformer 2 The group vector measurement for three phase tr

重庆格纳迪机电设备有限公司      [2015-04-26 21:02:59 ]

GDZC series DC resistance tester

Application GDZC Series winding resistance tester are applied to measure the DC resistance of inductance circuit such as power transformer coil, current transformer coil and so on. Also the tester could be applied to measure the cable resistance in 4-wire mode. Functions 1 Windin

重庆格纳迪机电设备有限公司      [2015-04-26 20:58:40 ]

GDVJ-502A Insulating transformer oil dielectric strength tester

Product name Insulating oil tester 1) IEC60156/IS6792/BS5874/VDE0370-5 2) User-defined 3) 5 minute test 4) ASTMD877 5) ASTMD1816 6) JIS C 2101-99(S) 7) Proof "A" 8) Proof "B" Insulating oil tester technical index (1) AC220V±10% power supply input (2) Output voltage AC 0V~100KV (

重庆格纳迪机电设备有限公司      [2015-04-26 20:56:04 ]

GDGS Dielectric Loss Tester Tangent Delta Tester

Introduction GDGS automatic tangent delta tester is applied to measure the dielectric loss and capacitor value of insulation materials in high voltage power equipment. The non-power frequency voltage source is integrated in the tester to avoid power frequency interference. That m

重庆格纳迪机电设备有限公司      [2015-04-26 20:54:45 ]

Current Transformer Tester

Product model GDVA-405 Tests for Current Transformer 1 Excitation curve and parameters test 2 Turns ratio test 3 Ratio and phase error test 4 Polarity mark check 5 Winding resistance measurement 6 Secondary loop burden measurement 7 Error line curve test for protection CT 8 Trans

重庆格纳迪机电设备有限公司      [2015-04-26 20:53:05 ]

ct analyzer manufacturer with ISO CE certification

Product model GDVA-405 Tests for Current Transformer 1 Excitation curve and parameters test 2 Turns ratio test 3 Ratio and phase error test 4 Polarity mark check 5 Winding resistance measurement 6 Secondary loop burden measurement 7 Error line curve test for protection CT 8 Trans

重庆格纳迪机电设备有限公司      [2015-04-26 20:51:28 ]

PH-221 Digital pH and Temperature Controller

PH-221 Digital pH and Temperature Controller ( Backlit display ) Measuring range pH 0.00 ~ 14.00 pH Temp 0 ~ 50℃ ( 32℉ -122℉ ) Resolution pH 0.01 pH Temp 0.1℃ ( 0.2℉ ) Accuracy pH ±0.02pH Temp ± 0.5℃ Display pH 4-digital LCD Temp 3-digital LCD Automatic Temper

Kelilong Electron Co.Ltd      [2015-04-25 17:14:49 ]

KL-1385/1385L Waterproof EC/CF/TDS Meter

KL-1385/1385L Waterproof EC/CF/TDS Meter Measuring range EC 0.00~19.99EC CF 0.0~199CF TDS 10~19990ppm Resolution EC 0.01EC CF 0.1CF TDS 10ppm Accuracy ±2℅F·S Operating Temperature 0℃~50℃ Automatic Temperature Compensation 0℃~50℃ Power Supply 4×1.5V(AG13) Dimensions 1

Kelilong Electron Co.Ltd      [2015-04-25 17:12:47 ]

KL-1382 Conductivity Tester

KL-1382 Conductivity Tester Model KL-1382 Measuring range 0~1999 us/cm Accuracy ±2℅F·S Resolution 1 us/cm Display 4-digital LCD Environment Temperature 0℃~50℃ Humidity ≤95℅ Automatic Temperature Compensation 0℃~50℃ Power Supply 2×3V(CR2032 Battery) Dimensions 15

Kelilong Electron Co.Ltd      [2015-04-25 17:11:26 ]

KL-1383C conductivity meters

KL-1383C conductivity meters Model KL-1383C Measuring range 100~19900us/cm Accuracy ±2℅F·S Resolution 100us/cm Automatic Temperature Compensation 0℃~50℃ Power Supply 4×1.5V(AG13) Dimensions 150mm×29mm×15mm Weight 51g

Kelilong Electron Co.Ltd      [2015-04-25 17:10:03 ]

KL-026 multi-parameter Water Quality Monitor

KL-026 multi-parameter Water Quality Monitor Measuring range PH:0.00~14.00 PH ℃:-50℃~70℃ (-58℉~158℉) EC:0.00~19.99EC CF:0.0~199CF TDS:10~19990ppm Resolution PH:0.01PH ℃:0.1℃(0.2℉) EC:0.01EC CF:0.1CF TDS:10 ppm Accuracy PH:±0.1 PH

Kelilong Electron Co.Ltd      [2015-04-25 17:06:14 ]

KL-025M Online PH Monitor

KL-025M Online PH Monitor Range 0.00-14.00PH Resolution 0.01PH Accuracy ±0.1PH(│T1-T2│≤5℃) ±0.2PH(│T1-T2│>5℃) (T1--The environment temperature, T2--The test liquid temperature) Power Supply DC 6V(include), with adaptor Operating Temperature 0℃~50℃ Dimensio