UV peak wavelength 365nm IR peak wavelength 1400nm Visible light 380nm-760nm full wavelength, in line with CIE photopic luminosity function Resolution 0.1% Measurement accuracy better than ± 2% (colorless and uniform transparent material) Maximum sample thickness Weight about 16
linshangtech [2020-12-17 10:03:36 ]
UV peak wavelength 365nm IR peak wavelength 940nm Visible light 380nm-760nm full wavelength, in line with CIE photopic luminosity function Resolution 0.1% Measurement accuracy better than ± 2% (colorless and uniform transparent material) Maximum sample thickness Weight About 165
linshangtech [2020-12-17 09:57:11 ]
UV peak wavelength 365nm IR peak wavelength 1400nm Visible light 550nm Resolution 0.1% Measurement accuracy 0.1% Test card slot better than ± 2% (colorless and uniform transparent material) weight about 590g Dimension 216mm × 134mm × 29mm (L*H*W) Power supply 5V AC/DC Adapter
linshangtech [2020-12-17 09:55:22 ]
UV peak wavelength 365nm IR peak wavelength 940nm, 1400nm, Full IR and SHGC Visible light peak wavelength 380-760nm Resolution 0.1% Measurement accuracy better than ± 2% (colorless and uniform transparent material) Test card slot 47mm×91mm (W*H) Weight about 590g Dimension 216m
linshangtech [2020-12-17 09:53:20 ]
UV peak wavelength 365nm Visible light peak wavelength 380-760nm IR peak wavelength 1400nm Resolution When the measured value is the resolution is 0.1%; for other ranges, the resolution is 1% Measurement accuracy better than ± 2% (colorless and uniform transparent materials) Tes
linshangtech [2020-12-17 09:50:32 ]
UV peak wavelength 365nm IR peak wavelength 940nm Visible light 380-760nm, conform to CIE photopic luminosity function Resolution When the measured value is resolution is 0.1%; for other ranges, the resolution is 1% Measurement accuracy Better than ± 2% (colorless and uniform tr
linshangtech [2020-12-17 09:48:34 ]
Size 175mm*120mm*30mm (L*W*H) Test slot 20mm * 70 mm (W*H) Weight 360g Resolution 0.1% Accuracy ±2% (Colorless and transparent material) UV Peak wavelength 365nm Visible light 380-760nm, conforming to the CIE photopic luminosity function IR Peak wavelength 940nm Power Supply 4*A
linshangtech [2020-12-17 09:46:04 ]
UV Peak wavelength 365nm IR Peak wavelength 1400nm Visible light 380-760nm, conform to the CIE photopic luminosity function Accuracy ±2% (Colorless and transparent material) Resolution 0.1% Test Slot 6mm *58mm (W*D) Dimension 146 mm ×73 mm ×24 mm (L*W*H) Display 128*128 Dot ma
linshangtech [2020-12-17 09:43:36 ]
UV Peak wavelength 365nm IR Peak wavelength 940nm Visible light 380-760nm, conform to the CIE photopic luminosity function Accuracy ±2% (Colorless and transparent material) Resolution 0.1% Test Slot 6mm * 58mm (W*D) Dimension 146 mm ×73 mm ×24 mm (L*W*H) Display 128*128 Dot ma
linshangtech [2020-12-17 09:41:23 ]
Illumination geometry D/8, Specular Component Include (SCI) Illumination light source Full spectrum LED light source Measuring aperture 8mm Measurement conditions Light source D65, field of view 10° Measuring time about 1s Color spaces CIE Lab, Luv, LCh, Yxy, CMYK, RGB, Hex Colo
linshangtech [2020-12-17 09:37:38 ]
Illumination geometry 45/0 (45°annular illumination, 0° viewing angle) Illumination light source Full spectrum LED light source Measuring aperture 8mm Measurement conditions Light source D65, field of view 10° Measuring time about 1s Color space CIE Lab, Luv, LCh, Yxy, CMYK, R
linshangtech [2020-12-17 09:35:01 ]
Determining the resistance of glazing material to impact by the penetration method. Principle The specimen is supported vertically in a steel frame and an impact shot bag is released from a pre-determined height to strike the specimen at the centre. The height is progressively in
Qinhuangdao Yuanchen Technology Equipment Co., Ltd. [2020-12-16 15:22:13 ]
Parameters UVALED-X0 Probe Spectral response 340nm-420nm, calibrated with 395nm UV LED Power measuring range 0 - 20000mW / cm² Resolution 1mW / cm² Energy measuring range 0-9999999mJ/ cm² Record time 0-99999s Measuring accuracy ±10% Sampling speed 2048 times/second Optional u
linshangtech [2020-12-15 09:35:06 ]
Parameters UVA-X1 Probe Spectral response Spectral response 260nm-400nm, λp = 365nm Power measuring range 0 - 200000μW/cm² Resolution 0.1μW/cm² Energy measuring range 0-9999999μJ/cm² Record time 0-99999s Measuring accuracy ±10% Sampling speed 6 times/second Optional unit
linshangtech [2020-12-15 09:31:56 ]
Parameters UVA-X0 Probe Spectral response 315nm-400nm, λp = 365nm Power measuring range 0 - 2000mW / cm² Resolution 0.1mW / cm² Energy measuring range 0-9999999mJ/cm² Record time 0-99999s Measuring accuracy ±10% Sampling speed 2048 times/second Optional unit mW / cm² (defau
linshangtech [2020-12-15 09:26:51 ]
Parameters UVB-X0 Probe Spectral response 280-315nm,suitable for UVB light source 297nm, 308nm, 313nm etc. Power measuring range 0 - 200000μW/cm² Resolution 0.1μW/cm² Energy measuring range 0-9999999μJ/cm2 Record time 0-99999s Measuring accuracy ±10% Sampling speed 6 times/
linshangtech [2020-12-15 09:20:35 ]
Parameters UVCLED-X0 Probe Spectral response 240nm-320nm, suitable for testing 260nm-285nm sterilization UV LED Power measuring range 0 - 200000μW / cm² Resolution 0.1μW / cm² Energy measuring range 0-9999999μJ/cm² Record time 0-99999s Measuring accuracy ±10% Sampling spee
linshangtech [2020-12-15 09:18:33 ]
UV intensity meter technical parameters Parameters UVCWP-X1 Probe Spectral response 230nm-280nm, λp = 254nm Power measuring range 0 - 200000μW / cm² Resolution 0.1μW / cm² Energy measuring range 0-9999999μJ/cm² Record time 0-99999s Measuring accuracy ±10% Sampling speed 6
linshangtech [2020-12-15 09:16:50 ]
Ultraviolet disinfection and sterilization are widely used in hospitals, disease control centers, pharmaceutical factories, food factories, schools, nurseries, cinemas, buses, offices, homes, etc. It can purify the air and prevent bacteria from spreading through the air or passin
linshangtech [2020-12-15 09:14:38 ]
LS125 is a smart host that can support 9 different probes. It can intelligently identify different probes. This host is connected to the probe through an aviation plug. The main function of the host is to display the test data. The host equipped with the probe can be used for ult
linshangtech [2020-12-15 09:07:08 ]