Wheel Shape Load NQ3~5

Rated Capacities 1,2,5,10,20(t) Rated Output 2.0 mV/V±0.25% Non-linearity 0.05% R O.;0.03% R O. Hysteresis 0.05% R O.;0.03% R O. Repeatability 0.05% R O.;0.03% R O. Creep(30min) 0.05% R O.;0.03% R O. Temperature Effect On Output 0.005%R O./℃ http://www mavi

Hope Technologic(Xiamen) Co.,Ltd      [2015-03-21 12:35:14 ]

Crane Load Cell NY3

Rated Capacities 2,3,5,7.5,10,20(t) Rated Output 2.0 mV/V±0.25% Non-linearity 0.03% R O. Hysteresis 0.03% R O. Repeatability 0.03% R O. Creep(30min) 0.03% R O. Temperature Effect On Output 0.003%R O./℃ http://www mavincn com/

Hope Technologic(Xiamen) Co.,Ltd      [2015-03-21 12:34:49 ]

Crane Load Cell NY5

Rated Capacities 50,100,200,500,1000 ( kg ) Rated Output 2.0 mV/V±1% Non-linearity 0.15% R O. Hysteresis 0.15% R O. Repeatability 0.15% R O. Creep(30min) 0.15% R O. Temperature Effect On Output 0.02%R O./℃ http://www mavincn com/

Hope Technologic(Xiamen) Co.,Ltd      [2015-03-21 12:34:39 ]

Crane Load Cel NS1,2,4

Rated Capacities 100,200,250,300,500,750 (kg) 1,1.5,2,2.5,3,5(t ) Rated Output 2.0 mV/V±0.25%;3.0 mV/V±0.25% Non-linearity 0.03% R O. Hysteresis 0.03% R O. Repeatability 0.03% R O. Creep(30min) 0.03% R O. Temperature Effect On Output 0.002%R O./℃ Tem

Hope Technologic(Xiamen) Co.,Ltd      [2015-03-21 12:34:33 ]

Column Type Load NC1

Rated Capacities 50,100,200 (kg) Rated Output 2.0 mV/V±1% Non-linearity 0.05% R O. Hysteresis 0.05% R O. Repeatability 0.05% R O. Creep(30min) 0.05% R O. Temperature Effect On Output 0.01%R O./℃ Temperature Effect On Zero 0.01%R O./℃ http://www mavincn com/

Hope Technologic(Xiamen) Co.,Ltd      [2015-03-21 12:34:22 ]

Column Type Load NC2

Rated Capacities 5,10,20,50 (kg) Rated Output 2.0 mV/V±1% Non-linearity 0.05% R O. Hysteresis 0.05% R O. Repeatability 0.05% R O. Creep(30min) 0.05% R O. Temperature Effect On Output 0.01%R O./℃ Temperature Effect On Zero 0.01%R O./℃ http://www mavincn com/

Hope Technologic(Xiamen) Co.,Ltd      [2015-03-21 12:34:17 ]

Double Shear Beam ND2

Rated Capacities 20,25,30 , 40 (t) Rated Output 2.0 mV/V±0.25% Non-linearity 0.03% R O. Hysteresis 0.03% R O. Repeatability 0.03% R O. Creep(30min) 0.03% R O. Temperature Effect On Output 0.002%R O./℃ Temperature Effect On Zero 0.003%R O./℃ Zero Balance ±0.0200 mV/V

Hope Technologic(Xiamen) Co.,Ltd      [2015-03-21 12:34:03 ]

Double Shear Beam ND7

Rated Capacities 15 (t) Rated Output (1.55~1.65) mV/V Non-linearity 0.05~0.03% R O. Hysteresis 0.05~0.03% R O. Repeatability 0.05~0.03% R O. Creep(30min) 0.05~0.03% R O. Temperature Effect On Output 0.003%R O./℃ Temperature Effect On Zero 0.003%R O./℃ http://www mavincn c

Hope Technologic(Xiamen) Co.,Ltd      [2015-03-21 12:33:53 ]

Shear Beam Load NB9

Rated Capacities 0.5,1,2,3(t) Rated Output 2.0 mV/V±0.25% Non-linearity 0.03% R O. Hysteresis 0.03% R O Repeatability 0.03% R O Creep(30min) 0.03% R O Temperature Effect On Output 0.002%R O./℃ http://www mavincn com/

Hope Technologic(Xiamen) Co.,Ltd      [2015-03-21 12:33:36 ]

Single Point Load NA165

Rated Capacities 3,5,6,10,15,20,30,35,40 (kg) Rated Output 2.0±0.10mV/V Non-linearity 0.02% R O. Hysteresis 0.02% R O. Repeatability 0.02% R O. Creep(30min) 0.02% R O. http://www mavincn com/

Hope Technologic(Xiamen) Co.,Ltd      [2015-03-21 12:33:27 ]

Indicator THW-101

Product Model THW-101 INDICATOR *1/30,000 display resolution (Internal resolution 1/1,000,000) *Can choose the division with 15000D, 30,000D, lb,according with the different environment, just need only one key *Full range tare,Auto zero tracking *With "Hold", "Division", "Tare"

Hope Technologic(Xiamen) Co.,Ltd      [2015-03-21 12:33:17 ]

Single Point Load Cell NA12,NA13

Rated Capacities 0.3,0.5,0.6,0.75,1,2(kg) Rated Output 0.8±0.15 mV/V;1.0±0.15 mV/V;2.0±0.2 mV/V Non-linearity 0.02% R O. Hysteresis 0.02% R O. Repeatability 0.02% R O. Creep(30min) 0.02% R O. http://www mavincn com/

Hope Technologic(Xiamen) Co.,Ltd      [2015-03-21 12:32:58 ]

Indicator THC

Product Model THC INDICATOR *1/30,000 display resolution (Internal resolution 1/1,000,000) *Kilogram(kg) and pound(g) weighing modes *LCD display with backlight *Rechargeable, both AC and DC can be used . *Full range tare,Auto zero tracking,Pre-tare, Data accumulation *Auto a

Hope Technologic(Xiamen) Co.,Ltd      [2015-03-21 11:28:11 ]

GD-0175 Distillate Fuels Oxidation Stability Test laboratory instrument

Measurement Standards 1. SH/T0175 Test Methods for Oxidation Stability of Distillate Fuels. Configuration 1. Water bath. 2. Flow control system. 3. Temperature control system. 4. Cooling water control system. Characteristics 1. It is a floor stand type integrated instrument and i

重庆格纳迪设备有限公司      [2015-03-17 14:12:11 ]

GD-30011 high temperature muffle furnace Carbon Residue Tester

GD-30011 high temperature muffle furnace Carbon Residue Tester in lubricating oil, heavy liquid fuels (Digital Temperature Controlled Electric Furnace Methods) Purpose The Carbon Residue Tester is designed and made as per the Industry Standard of Petrochemical SH/T0170 “Test Me

重庆格纳迪设备有限公司      [2015-03-17 14:10:59 ]

GD-3536D ASTM D92 Fully-Automatic cleveland Open Cup Flash Point Tester

Ⅰ . Introduction GD-3536D ASTM D92 Fully-Automatic cleveland Open Cup Flash Point Tester is designed and made as per the National Standard of People’s Republic of China GB/T3536 “Test Methods for Flash Point and Fire Point of Petroleum Products (Cleveland Open Cup Method)

重庆格纳迪设备有限公司      [2015-03-17 14:09:02 ]

GD-3536A Automatic Cleveland Open Cup Flash Point Testing Equipment

Purpose This GD-3536A Automatic Cleveland Open Cup Flash Point testing equipment is designed and made as per GB/T3536-2008 Petroleum Products - Determination of Flash and Fire Points - Cleveland open cup method and ASTM D 92 Standard Test Method for Flash and Fire Points by Cleve

重庆格纳迪设备有限公司      [2015-03-17 14:07:30 ]

GDE-1B Engler Viscometer /Engler viscosity Viscometer

I Brief Introduction The Engler Viscometer is designed and made as per the National Standard GB/T266 “Test Methods for Engler Viscosity of Petroleum Products” and the Industry Standard JTJ052 Specification and Test Methods of Bitumen and Bituminous Mixture for Highway Enginee

重庆格纳迪设备有限公司      [2015-03-17 14:05:54 ]

GD-0308 Hydraulic Oil Air Release Value laboratory equipment

GD-0308 Hydraulic Oil Air Release Value laboratory equipment GD-0308 Hydraulic Oil Air Release Value Tester is designed and made as per SH/T0308-92. It is used to determine air release value of fire resistant oil, hydraulic oil, turbine oil and other petroleum products. It includ

重庆格纳迪设备有限公司      [2015-03-17 14:04:16 ]

GD--8017 Crude Oil Vapor Pressure laboratory tester (Reid Method )

I Brief Introduction The instrument is designed and made as per the national standard of People’s Republic of China GB/T8017 Test Method for Vapor Pressure of Petroleum Products (Reid Methods). It is suitable to determine vapor pressure of gasoline, volatile crude oil and other

重庆格纳迪设备有限公司      [2015-03-17 14:03:07 ]