Punching range Φ22.5-61.5mm in the 3.5mm mild steel Punching force 66KN Stroke 22mm Length approx.320mm Weight approx.2.7kg Packge plastic box Weight box approx.1.20kg Accessories Round Knockout Punches Type D 22.5,28.3,34.6,43.2,49.6,61.5mm 7/16"x3/4" Draw Stud 1pc 3/4"x3/4" Dr
河北力能电力器材厂 [2013-09-15 08:47:20 ]
Punching range Φ22.5-61.5mm in the 3.5mm mild steel Punching force 69KN Stroke 22mm Length approx.310mm Weight approx.2.2kg Packge plastic box Weight box approx.1.20kg Accessories Round Knockout Punches Type D 22.5,28.3,34.6,43.2,49.6,61.5mm 7/16"x3/4" Draw Stud 1pc 3/4"x3/4" Dr
河北力能电力器材厂 [2013-09-15 08:46:57 ]
Crimping force 35KN Stroke 9mm Crimp/charge 320 times(Cu 150mm 2 ) Crimping cycle 3-6s(depend on the size of cable) Voltage 18v Capacity 3.0Ah Charging time 2 hours Package steel box Accessories Crimping dies 4,6,8,10,16,25,35,50,70,95,120,150mm 2 Battery 2pcs Charger 1pcs Sealin
河北力能电力器材厂 [2013-09-15 05:50:08 ]
Max. output 20-*50KN Stroke 35mm Throat depth 200mm Time/cycle : 3 ~ 8s Crimp/charge 200times Voltage of battery 18V DC Capacity 3Ah Voltage 100 ~ 240V AC Charging time 2 hours Accessories Battery 2pcs Charger 1pcs Sealing ring of cylinder 1set Sealing ring of safety valve
河北力能电力器材厂 [2013-09-15 05:49:41 ]
Crimping force 120KN Stroke 20mm Crimp/charge 150 times(Cu 150mm 2 ) Crimping cycle 4s-12s(depend on the size of cable) Voltage 18v Capacity 3.0Ah Charging time 2 hours Package steel box Accessories Crimping dies 16,25,35,50,70,95,120,150,185,240, 300 , 400mm 2 Battery 2pcs Cha
河北力能电力器材厂 [2013-09-15 04:49:58 ]
Model No. SH-70A Packing carton box or according to your requirements Delivery time within 1-15 days after decision of your detailed requirements and advance payment. Details Introduction C head is made of High strength steel forging 10.5/13.5/17.5/20.5mm( tools take these four k
河北力能电力器材厂 [2013-09-15 04:46:04 ]
Property value Model specification 4.5mm,6mm , 8mm , 10mm , 11mm , 12mm , 13mm , 14mm , 15mm , 16mmfor your choice,and we can also accept OEM order Length 30,50,60,80,100,120,150,180,200,250,300,350,400,450,500 meters for choice. Material Fiberglass (inner) and high density polyt
河北力能电力器材厂 [2013-09-15 04:41:30 ]
Specifications 1.Short leadtime; 2.Quality guaranteed; 3.all size and model available; 4.Reasonable price. CP series AGPH9560,AGPH9410,AGPH9130,AGPH9050,AGPH9470,AGPH9460,AGPH9060,AGPH9430,AGPH9570,AGPH9550,AGPH9190,AGPH9480,AGPH9200,AGPH9440AMPH8710,AMPH8720,AMPH8730,AMPH3044,AM
ZK Electronic Technology Co., Limited [2013-09-09 04:46:50 ]
Specifications 1.Short leadtime; 2.Quality guaranteed; 3.all size and model available; 4.Reasonable price. QP3 ADBPN8523 QP 3 PICK UP NOZZLE 0.7 ADBPN8533 QP 3 PICK UP NOZZLE 1.0 ADBPN8113 QP 3 PICK UP NOZZLE 1.3 ADBPN8123 QP 3 PICK UP NOZZLE 1.8 ADBPN8133 QP 3 PICK UP NOZZLE 2.5
ZK Electronic Technology Co., Limited [2013-09-09 04:34:42 ]
DC direct current high voltage generator is mainly used for the testing of the performance of insulation materials suffered by the high voltage, DC discharge of long gap, and the insulation performance of high power equipment like power cable, power capacitance, generator group a
Fivestar HV Testing Equipment Co., Limited. [2013-08-16 04:12:15 ]
Voltage up to 2400kV High voltage DC test system is mainly used for HV technology research test, insulation material research test and DC dielectric test of HV products, such as power cable, power transformer, arrester, air gap, insulator chain, HV bushing and instrument transfor
Fivestar HV Testing Equipment Co., Limited. [2013-08-16 04:10:52 ]
Voltage up to 1000kV Current up to 4A SF6 gas insulated test transformers are espencially designed for testing metal-clad switchgear (GIS) in the factory and on-site, and for testing on-site substation equipment. The conventional transformer can be flanged directly to the GIS. Th
Fivestar HV Testing Equipment Co., Limited. [2013-08-16 04:08:59 ]
Conventional AC test transformers are especially designed to testing objects of medium capacitance. These system are particularly suited for tests requiring stable voltage even if the load changes under voltage (corona, wet & pollution tests) or when the load in inductive (induct
Fivestar HV Testing Equipment Co., Limited. [2013-08-16 04:07:53 ]
Voltage 10kV - 2250kV (single unit YDTW up to 750kV, cascaded YDTCW up to 2250kV) Current 0.1A -40A The AC test transformers are especially designed for medium capacitance testing object, such as power transformers, cables, generators, motors, GIS switchgears, bushings and arrest
Fivestar HV Testing Equipment Co., Limited. [2013-08-16 04:00:42 ]
Current 4000A, 5000A, 6000A, 7000A or above Heat cycling test set is designed to raise and control the temperature of the conduct simulating high current load in electric circuit. The high current is generated by the ring core heating transformer. And temperature measuring is ach
Fivestar HV Testing Equipment Co., Limited. [2013-08-16 03:59:22 ]
Voltage up to 800kV-200kW (suitable for the power cable up to 525kV) The water termination and water conditioning unit is used for high voltage testing of extruded insulation power cables, to improve and control the electrical field distribution at the end of the cable. There is
Fivestar HV Testing Equipment Co., Limited. [2013-08-16 03:56:53 ]
SF6 gas insulated series resonant test system is special designed for testing of gas insulation switchgear and gas insulation substations. The system can be connected with the GIS directly, which bring great convenient to the testing. Compared to oil insulated resonant system, It
Fivestar HV Testing Equipment Co., Limited. [2013-08-16 03:55:32 ]
Voltage 10kV – 600kV Current 5A – 80A Tank type AC series resonant test system is special designed for the high capacitance load, such as power cable. The huge system is suitable for testing in the factory or on-site. There are two different design variable frequency or adjus
Fivestar HV Testing Equipment Co., Limited. [2013-08-16 03:54:25 ]
Voltage up to 2000kV Current up to 40A Adjustable inductance resonant test system is designed to compensate capacitance in the testing circuit precisely by tuning inductance of the test system. The natural resonance frequency of the test system matches feed-in mains, usually 50/6
Fivestar HV Testing Equipment Co., Limited. [2013-08-16 03:50:35 ]
Voltage up to 2400kV Frequency 20-300Hz Variable frequency resonant test system vary the output frequency to tune the system to the load capacitance creating a resonant circuit. And the output frequency is typically in the range of 20 to 300Hz. It is ideal for commissioning tests