VDT Si-Fe silicone pad mounted dry type transformer 11.4KV (Standard)

Drawing 1. Comply with IEC 60076-11 2. Design temperature rise is Class F 100 VDT Si-Fe silicone pad mounted dry type transformer 11.4KV (Standard) Drawing 1. Comply with IEC 60076-11 2. Design temperature rise is Class F 100 3. Insulating level is Class H 220 4. Without Tank (IP

Grand Power River Co., Ltd.   

Switching Power Transformer E44

Switching Power Transformer E44 37 E44 PC40MB3other 191 BP-066 35.5 46 39.5 16(8-8)

EIWA Co.,Ltd.   

20MVA, 132/11.5kV, Dyn 11 mobile substation power transformer

20MVA, 132/11.5kV, Dyn 11 mobile substation power transformer Mobile substations are the best solution for emergency power supply to the loads as it takes a longer time to establish a new substation and/or after finalizing the construction the mobile substation could be moved eas

Iran Transfo Corporation.   

Toroidal Transformer -300 VA

300 VA Type Output [VAC] Ampere [A] P 0 [W] OD [mm] ID [mm] H [mm] Weight [kg] 3300-124 24 12,5 2 112 37 60 2,6 3300-209 2 x 9 2 x 16,67 2 112 37 60 2,6 3300-212 2 x 12 2 x 12,50 2 112 37 60 2,6 3300-215 2 x 15 2 x 10,00 2 112 37 60 2,6 3300-218 2 x 18 2 x 8,33 2 112 37 60 2,6 33

TransElectro   

Furnace Duty / Special Transformers

Furnace Duty / Special Transformers 11kV/1200A/5P/3Ph

alwaye group   

EB-2 Cal-Av Labs

Beaded 2 KW CW/ 6 KW PEP

Array Solutions   

Tube Transformers

PT-180 280V-250V-0-250V-280V 0.22A 6.3V 2.5A ( x 3) 5V 3A

Tube technologies   

lan magnetic transformer

Specification VP2009 LFDescription 10/100/1000 BASE TX VOICE OVER IP MAGNETICS MODULEPDF File

Bothhand Enterprise   

Telecom Transformer

Model Number LTE 2988 Model Number LTE 2988 Telecom Transformer

LI TONE ELECTRONICS CO., LTD.   

Current & Potential Transformers

3.3 / 6.6 / 11kv Epoxy resin cast current Transformer, for Indoor use. For 11kv. Suitable H T. Panel 3.3 / 6.6 / 11kv Epoxy resincast current Transformer, forIndoor use. For 11kv Suitable H T. Panel

kaydee co.   

Resin Cast Potential Transformer

In AC circuits, for measuring large voltages a specially constructed accurate ratio Potential Transformers are used. In AC circuits, for measuring large voltages a specially constructed accurate ratio Potential Transformers are used. Their function is to reduce the supply Voltage

INTRANS ELECTRO COMPONENTS PVT. LTD   

100 Voltage Line Matching Audio Transformer

Model Number ELM-1000501 Model Number ELM-1000501 40 Hz ~ 12K Hz 3 dB

Elytone Electronic Co., Ltd   

Voltage transformers

Three phase, three limb VT for effectively earthed,non-effectively earthed and unearthed systems Voltage transformers of standard ratios 3.3kV/110 V, 6.6kV/110V, 11 kV/110V are available in four constructions

KAPPA ELECTRICALS (P) LTD.   

ROUND TRANSFORMER, 12V, 35VA CIRCUMFERENCE: 5,7CM

Article Number 451022 OUND TRANSFORMER, 12V, 35VA CIRCUMFERENCE 5,7CM Article Number 451022 Product variants ROUND TRANSFORMER, 12V, 20VA, CIRCUMFERENCE 5,3CM height 8 cm Circumference 5,7 cm voltage 230 Volt max. load 35 Watt Safety class IP 40 Material plastic housing remarks e

slvbyeldc   

15 kVA Autoformer

15 kVA Autoformer For Use With an Industrial Linear Accelerator Specifications Electrical Rated Power .......... Frequency .............. Number/Phases ..... Input ........................ Output ..................... Mechanical Length .................... Depth .................

QT&E's   

EI type power supply transformer

Payment Terms T/T,Western Union We hold a staff of 150, including 6 engineering technicians and 20 managers. As a professional manufacturer of high-quality transformers, we mainly put out EI transformer, annular transformer, high, low frequency transformers, and manostat, etc, al