Multifunction meters for safety test on installations and network analysis Model:W1292

Multifunction meters for safety test on installations and network analysis Model:W1292 Cat.No:
 


Multifunction meter for safety test verifies on electrical plants and network analysis on Single phase systems
W1292 is a complete model to perform all safety tests in compliance to VDE 0413, measure of values of environmental parameters (temperature/humidity, illuminance, sound level with optional probes), leakage current with optional clamp and to perform a network power quality of single phase in compliance to EN50160 guideline.RCDs which suddenly trip out, transformers which overheat, motors which burn out, voltage sags and surges which create problems, all these problems could be easily solved with W1292. The meter permits to perform a Loop impedance measurement (P-P, P-N, P-PE) also with high resolution (0.1mOhms) with the use of IMP57 optional accessory and five predefined recording settings are integrated in order to to help the user on the most common situation which are present on the network quality (EN50160, Voltage Anomalies, Harmonics, Start-Up and Power & Energy). W1292 can perform current measurements up to 3000A AC also by using a flexible clamp type in order to perform measurements on big cables or bars also. Thanks to the PC interface and the powerful software you will create accurate documents qualifying your professionalism more and more.

STANDARD
CE mark
EN 61557-2 Insulation Resistance
EN 61557-4 Continuity test
EN 61557-5 Earth resistance
EN 61557-3 Loop impedance P-P, P-N, P-PE
EN 61557-6 RCD test
EN 61326 EMC Standards
EN 50160
EN 61008
EN 61009
EN 61010-032
EN 61010-1
EN 61036
EN 61557
16th edition
VDE 0413


FUNCTION

Continuity test of earth conductor with 200mA
Insulation resistance up to 1000VDC
Trip-out time of RCDs type A, AC, general and selective
Trip-out current of RCDs type A, AC, general and selective
Loop/Line impedance P-P, P-N, P-PE also at high resolution with IMP57 optional accessory
Prospective short circuit current
Global earth resistance without RCD tripping
2-wire and 3-wire earth resistance with rods
Ground resistivity
Contact voltage
Leakage current with optional HT96U transducer clamp
Phase sequence indication
TRMS measurement and recording electrical parameters in Single phase systems
Harmonics voltage and current up to 49

Multifunction meter for safety test verifies on electrical plants and network analysis on Single phase systems

  • Country:United States
  • telephone:1-510-8708483
Multifunction meter for safety test verifies on electrical plants and network analysis on Single phase systems
*Your name:
*Your Email:
*To:BRIMSTONE INC
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters Remaining: 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

We do inquire for you , please wait ...