Multifunction meters for safety test on installations and network analysis Model:W1292 | Cat.No: |
Multifunction meter for safety test verifies on electrical plants and network analysis on Single phase systems W1292 is a complete model to perform all safety tests in compliance to VDE 0413, measure of values of environmental parameters (temperature/humidity, illuminance, sound level with optional probes), leakage current with optional clamp and to perform a network power quality of single phase in compliance to EN50160 guideline.RCDs which suddenly trip out, transformers which overheat, motors which burn out, voltage sags and surges which create problems, all these problems could be easily solved with W1292. The meter permits to perform a Loop impedance measurement (P-P, P-N, P-PE) also with high resolution (0.1mOhms) with the use of IMP57 optional accessory and five predefined recording settings are integrated in order to to help the user on the most common situation which are present on the network quality (EN50160, Voltage Anomalies, Harmonics, Start-Up and Power & Energy). W1292 can perform current measurements up to 3000A AC also by using a flexible clamp type in order to perform measurements on big cables or bars also. Thanks to the PC interface and the powerful software you will create accurate documents qualifying your professionalism more and more. STANDARD CE mark EN 61557-2 Insulation Resistance EN 61557-4 Continuity test EN 61557-5 Earth resistance EN 61557-3 Loop impedance P-P, P-N, P-PE EN 61557-6 RCD test EN 61326 EMC Standards EN 50160 EN 61008 EN 61009 EN 61010-032 EN 61010-1 EN 61036 EN 61557 16th edition VDE 0413 FUNCTION Continuity test of earth conductor with 200mA Insulation resistance up to 1000VDC Trip-out time of RCDs type A, AC, general and selective Trip-out current of RCDs type A, AC, general and selective Loop/Line impedance P-P, P-N, P-PE also at high resolution with IMP57 optional accessory Prospective short circuit current Global earth resistance without RCD tripping 2-wire and 3-wire earth resistance with rods Ground resistivity Contact voltage Leakage current with optional HT96U transducer clamp Phase sequence indication TRMS measurement and recording electrical parameters in Single phase systems Harmonics voltage and current up to 49 |
Multifunction meter for safety test verifies on electrical plants and network analysis on Single phase systems
Multifunction meter for safety test verifies on electrical plants and network analysis on Single phase systems |