BTS-60V40A | Battery Testing System | |||||||||||
Model: | BTS- | 60 | V | 40 | A | Material Code: | CT-4001 | -60V40A | - | NA | - |
|
Description | Product Specification | |||||||||||
AC Input | AC 220V±10% 50Hz | |||||||||||
Power | 3139 | W | ||||||||||
Resolution | AD: 16bit; DA: 16bit | |||||||||||
Impedance Input | ≥1MΩ | |||||||||||
Voltage | Measuring Range | 300mV~60V | ||||||||||
Discharge Min Voltage | 3V | |||||||||||
Accuracy | ± 0.1% of FS | |||||||||||
Stability | ± 0.1% of FS | |||||||||||
Current | Range | Charge: 200mA~40A Discharge: 200mA~40A | ||||||||||
Accuracy | ± 0.1% of FS | |||||||||||
Stability | ± 0.1% of FS | |||||||||||
Power | Output Power Per Channel | 2400W | ||||||||||
Stability | ± 0.2% of FS | |||||||||||
Time | Rise Time | 20ms (10%FS~90%FS) | ||||||||||
StepTime | ≤ (365*24) hour/step | Time Format 00:00:00:000 (h:min:s:ms) | ||||||||||
Data Acquisition | Intervals | Time interval Δt: (100ms~60000s) | ||||||||||
Voltage interval ΔU: (120mV~60V) | ||||||||||||
Current interval ΔI: (80mA~40A) | ||||||||||||
Frequency | 10Hz | |||||||||||
Charge | Modes of Operation | CCC, CVC, CC & CVC, CPC | ||||||||||
End Conditions | Voltage, Current, Test Time, Capacity | |||||||||||
Discharge | Modes of Operation | CCD, CPD, CRD | ||||||||||
End Conditions | Voltage, Current, Test Time, Capacity | |||||||||||
Pulse | Charge | CCC | ||||||||||
Discharge | CCD | |||||||||||
Minimum Pulse Width | 500ms | |||||||||||
Automated Switch | Automated switch from charge to discharge for each pulse | |||||||||||
End Condition | Voltage, Test Time | |||||||||||
Cycle | Cycles | 65535 | ||||||||||
Steps | 254 | |||||||||||
Nested Function | Max three levels of loops | |||||||||||
Protective Function | Power-off data protection | |||||||||||
Off-line Operating | ||||||||||||
User-defined safety (upper and lower) tolerance of current, voltage and delay time | ||||||||||||
Reverse-connecting protection | ||||||||||||
Channel Features | Independent pairs of closed loop for constant current source and constant voltage source | |||||||||||
Channels | Independent control | |||||||||||
Detection and Sampling | 4-wire Connecting | |||||||||||
Noise Density | <85dB | |||||||||||
Data Management | MYSQL Database | |||||||||||
Communication Means | TCP/IP Protocol | |||||||||||
Exports Formats | EXCEL, TXT, Graph | |||||||||||
Communication Interface | Ethernet Port | |||||||||||
Number of Channels Per Cabinet | 1 | |||||||||||
Operating Environment | ||||||||||||
Description | Product Specification | |||||||||||
Operating Temperature | 0ºC~40ºC | |||||||||||
Storage Temperature | -10ºC~50ºC | |||||||||||
Operating Humidity | ≤70% RH | |||||||||||
Storage Humidity | ≤80% RH |