Model number | TGS2603 | |
Sensing principle | MOS type | |
Standard package | TO-5 metal can | |
Target gases |
Air contaminants
(Trimethylamine, methyl mercaptan, etc.) |
|
Typical detection range | 1 ~ 10ppm EtOH | |
Heater voltage | 5.0±0.2V AC/DC | |
Circuit voltage | 5.0±0.2V DC | Ps≤15mW |
Load resistance | variable | 0.45kΩ min. |
Heater resistance | approx 67Ω at room temp. (typical) | |
Heater current | 48mA | |
Heater power consumption |
240mW | VH =5.0V AC/DC |
sensor resistance | 20kΩ ~ 200kΩ in air | |
Sensitivity (change ratio of Rs) |
<0.5 |
Rs (10ppm EtOH)
Rs air |
Test gas conditions |
normal air
at 20±2˚C, 65±5%RH |
|
Circuit conditions |
Vc = 5.0±0.2V DC
VH = 5.0±0.2V AC/DC |
|
Conditioning period before test |
96 hours or longer |
TGS2603 - for detection of Odor and Air Contaminants Features * Low power consumption * High sensitivity to amine-series and sulfurous odor gases * High sensitivity to food odors * Long life and low cost * Uses simple electrical circuit Applications * Air cleaners * Ventilation ...